• Title/Summary/Keyword: Scan method

Search Result 1,540, Processing Time 0.032 seconds

Intraoral scanning of the edentulous jaw without additional markers: An in vivo validation study on scanning precision and registration of an intraoral scan with a cone-beam computed tomography scan

  • Julie Tilly Deferm;Frank Baan;Johan Nijsink;Luc Verhamme;Thomas Maal;Gert Meijer
    • Imaging Science in Dentistry
    • /
    • v.53 no.1
    • /
    • pp.21-26
    • /
    • 2023
  • Purpose: A fully digital approach to oral prosthodontic rehabilitation requires the possibility of combining (i.e., registering) digital documentation from different sources. This becomes more complex in an edentulous jaw, as fixed dental markers to perform reliable registration are lacking. This validation study aimed to evaluate the reproducibility of 1) intraoral scanning and 2) soft tissue-based registration of an intraoral scan with a cone-beam computed tomography (CBCT) scan for a fully edentulous upper jaw. Materials and Methods: Two observers independently performed intraoral scans of the upper jaw in 14 fully edentulous patients. The palatal vault of both surface models was aligned, and the inter-observer variability was assessed by calculating the mean inter-surface distance at the level of the alveolar crest. Additionally, a CBCT scan of all patients was obtained and a soft tissue surface model was generated using patient-specific gray values. This CBCT soft tissue model was registered with the intraoral scans of both observers, and the intraclass correlation coefficient(ICC) was calculated to evaluate the reproducibility of the registration method. Results: The mean inter-observer deviation when performing an intraoral scan of the fully edentulous upper jaw was 0.10±0.09 mm. The inter-observer agreement for the soft tissue-based registration method was excellent(ICC=0.94; 95% confidence interval, 0.81-0.98). Conclusion: Even when teeth are lacking, intraoral scanning of the jaw and soft tissue-based registration of an intraoral scan with a CBCT scan can be performed with a high degree of precision.

Test Generation for Partial Scanned Sequential Circuits Based on Boolean Function Manipulation (논리함수처리에 의한 부분스캔순차회로의 테스트생성)

  • Choi, Ho-Yong
    • The Transactions of the Korea Information Processing Society
    • /
    • v.3 no.3
    • /
    • pp.572-580
    • /
    • 1996
  • This paper describes a test generation method for sequential circuits which improves the application limits of the IPMT method by applying the partial scan design to the IPMT method. To solve the problem that the IPMT method requires enormous computation time in image computation, and generates test patterns after the partialscan design is introduced to reduce test complexity. Scan flip-flops are selected for the partial scan design according to the node size of the state functions of a sequential circuit in their binary decision diagram representations. Experimental results on ISCAS'95 benchmark circuits show that a test generator based on our method has achieved 100% fault coverage by use of either 20% scan FFs for s344, s349, and s420 or 80% scan FFs for sl423. However, test gener-ators based on the previous IPM method have not achieved 100% fault coverage for those circuits.

  • PDF

A ScanSAR Processing without Azimuth Stitching by Time-domain Cross-correlation (Azimuth Stitching 없는 ScanSAR 영상화: 시간영역 교차상관)

  • Won, Joong-Sun
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.3
    • /
    • pp.251-263
    • /
    • 2022
  • This paper presents an idea of ScanSAR image formation. For image formation of ScanSAR that utilizes the burst mode for raw signal acquisition, most conventional single burst methods essentially require a step of azimuth stitching which contributes to radiometric and phase distortions to some extent. Time-domain cross correlation could replace SPECAN which is most popularly used for ScanSAR processing. The core idea of the proposed method is that it is possible to relieve the necessity of azimuth stitching by an extension of Doppler bandwidth of the reference function to the burst cycle period. Performance of the proposed method was evaluated by applying it to the raw signals acquired by a spaceborne SAR system, and results satisfied all image quality requirements including 3 dB width, peak-to-sidelobe ratio (PSLR), compression ratio,speckle noise, etc. Image quality of ScanSAR is inferior to that of Stripmap in all aspects. However, it is also possible to improve the quality of ScanSAR image competitive to that of Stripmap if focused on a certain parameter while reduced qualities of other parameters. Thus, it is necessary for a ScanSAR processor to offer a great degree of flexibility complying with different requirements for different applications and techniques.

Efficient Test Data Compression Method (효율적인 테스트 데이터 압축 방법)

  • Jung, Jun-Mo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.690-692
    • /
    • 2012
  • This pape presents the efficient test data compression method considering test power dissipation in scan test of IP core. There are many researches about test data compression using scan slice selective encoding except power dissipation. We present the new algorithm that assigns the don't care value to be a minimal hamming distance between adjacent slices. Experimental results show that the power dissipation is reduced.

  • PDF

Curing Behavior and Morphology of DGEBA/NMA/2,4,6-tris(dimethylaminomethyl) phenol System (DGEBA/NMA/2,4,6-tris(dimethylaminomehyl)phenol 시스템의 경화거동 및 Morphology)

  • 김민영;김성호;최영선;김원호;황병선
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.05a
    • /
    • pp.118-121
    • /
    • 2001
  • The investigation of cure kinetics and morphology studies on DGEBA/PEI/Anhydride system were performed by differential scanning calorimetry and scanning electron microscopy. Autocatalystic kinetics model was applied by isothermal scan test. Ozawa method and Kissinger method was applied by temperature scan. Activation energy was 95kJ/mol for neat DGEBA/NMA, 120kJ/mol for DGEBA/PEI(10p.h.r.)/NMA. The generation of secondary phase of PEI was observed and its size was grown up by increasing contents of PEI.

  • PDF

Suggestion of OSMU Content New Business Market through Development of Integrated Platforms for Software-oriented Tailored Costume Production (소프트웨어 중심의 주문 형 의상제작 융합플랫폼 개발을 통한 OSMU콘텐츠 뉴비즈니스 시장 창출 제안)

  • Jung, Minsoo
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.8
    • /
    • pp.1021-1026
    • /
    • 2018
  • 3D SCAN enables easy human body measurement via a digital method in the process of film costume production which used to be done manually. Software-oriented computer graphic, which integrates 3D SCAN data in the process of manual film costume production, can induce quick and diverse design outcomes. While, 3D PRINT, which integrates computer graphic data in the process of manual film costume production, can automate the process of special costume production using a digital method. Integration of 3D Scan + Computer Graphic + 3D Print using integrated platforms for tailored costume production as developed in this study allows significant reduction of costume production period and costs. It also allows efficient integration of costume production outcomes in various industries related with OSMU contents in particular. In other words, using it, we can create a new business market that integrates multiple areas of film content, drama content and game content.

Low Power Scan Chain Reordering Method with Limited Routing Congestion for Code-based Test Data Compression

  • Kim, Dooyoung;Ansari, M. Adil;Jung, Jihun;Park, Sungju
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.5
    • /
    • pp.582-594
    • /
    • 2016
  • Various test data compression techniques have been developed to reduce the test costs of system-on-a-chips. In this paper, a scan chain reordering algorithm for code-based test data compression techniques is proposed. Scan cells within an acceptable relocation distance are ranked to reduce the number of conflicts in all test patterns and rearranged by a positioning algorithm to minimize the routing overhead. The proposed method is demonstrated on ISCAS '89 benchmark circuits with their physical layout by using a 180 nm CMOS process library. Significant improvements are observed in compression ratio and test power consumption with minor routing overhead.

Fabrication of Part and Its Evaluation Using Dual Laser in Solid Freeform Fabrication System (SFFS에서 듀얼 레이저를 이용한 부품 제작 및 평가)

  • Choi Jae-Won;Kim Dong-Soo;Doh Yang-Hoe;Lee Seok-Hee;Choi Kyung-Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.3 s.246
    • /
    • pp.334-341
    • /
    • 2006
  • A solid freeform fabrication (SFF) system using selective laser sintering (SLS) is currently recognized as a leading process and the SLS extends the applications to machinery and automobiles due to various employing materials. In order to fabricate a large part with SFF system, dual laser approach has been introduced. Since the building room is divided into two regions, each scan path for dual laser system is generated based on the single laser scan path. Scan paths for each laser have to be synchronized and consider mechanical strength against fracture at the interfaced region. This paper will address generation of single laser scan path which deals with special cases for unnecessary scan points and generation of dual laser scan path according to various divided regions to enhance mechanical strength. To evaluate the developed scan path method, the specimen will be fabricated and evaluated.

Establishment of Injection Protocol of Test Bolus for Precise Scan Timing in Canine Abdominal Multi-Phase Computed Tomography

  • Choi, Sooyoung;Lee, In;Choi, Hojung;Lee, Kija;Park, Inchul;Lee, Youngwon
    • Journal of Veterinary Clinics
    • /
    • v.35 no.3
    • /
    • pp.93-96
    • /
    • 2018
  • This study aimed to establish an injection protocol to determine the precise CT scan timing in canine abdominal multi-phase CT using the test bolus method. Three dynamic scans with different contrast injection parameters were performed using a crossover design in eight normal beagle dogs. A contrast material was administered at a fixed dose of 200 mg iodine/kg as a test bolus for dynamic scans 1 and 2, and 600 mg iodine/kg as a main bolus for dynamic scan 3. The contrast materials were administered with 1 ml/s in dynamic scan 1, and 3 ml/s in dynamic scan 2 and 3. The mean arrival time to the appearance of aortic enhancement in dynamic scan 3 was similar to that in dynamic scan 2, and different significantly to that in dynamic scan 1. The mean arrival time to the peak aortic and pancreatic parenchymal enhancement in dynamic scan 3 was similar to that in dynamic scan 1, and different significantly to that in dynamic scan 2. In multi-phase CT scan, a test bolus should be injected with the same injection duration of a main bolus, to obtain the precise arrival times to peak of arterial or pancreatic parenchymal enhancement.

Optimizing the maximum reported cluster size for normal-based spatial scan statistics

  • Yoo, Haerin;Jung, Inkyung
    • Communications for Statistical Applications and Methods
    • /
    • v.25 no.4
    • /
    • pp.373-383
    • /
    • 2018
  • The spatial scan statistic is a widely used method to detect spatial clusters. The method imposes a large number of scanning windows with pre-defined shapes and varying sizes on the entire study region. The likelihood ratio test statistic comparing inside versus outside each window is then calculated and the window with the maximum value of test statistic becomes the most likely cluster. The results of cluster detection respond sensitively to the shape and the maximum size of scanning windows. The shape of scanning window has been extensively studied; however, there has been relatively little attention on the maximum scanning window size (MSWS) or maximum reported cluster size (MRCS). The Gini coefficient has recently been proposed by Han et al. (International Journal of Health Geographics, 15, 27, 2016) as a powerful tool to determine the optimal value of MRCS for the Poisson-based spatial scan statistic. In this paper, we apply the Gini coefficient to normal-based spatial scan statistics. Through a simulation study, we evaluate the performance of the proposed method. We illustrate the method using a real data example of female colorectal cancer incidence rates in South Korea for the year 2009.