• Title/Summary/Keyword: Scan cells

Search Result 170, Processing Time 0.03 seconds

Interconnect Delay Fault Test in Boards and SoCs with Multiple System Clocks (다중 시스템 클럭으로 동작하는 보드 및 SoC의 연결선 지연 고장 테스트)

  • Lee Hyunbean;Kim Younghun;Park Sungju;Park Changwon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.1 s.343
    • /
    • pp.37-44
    • /
    • 2006
  • This paper proposes an interconnect delay fault test (IDFT) solution on boards and SoCs based on IEEE 1149.1 and IEEE P1500. A new IDFT system clock rising edge generator which forces output boundary scan cells to update test data at the rising edge of system clock and input boundary scan cells to capture the test data at the next rising edge of the system clock is introduced. Using this proposed circuit, IDFT for interconnects synchronized to different system clocks in frequency can be achieved efficiently. Moreover, the proposed IDFT technique does not require any modification of the boundary scan cells or the standard TAP controller is simple in terms of test procedure and is small in terms of area overhead.

A Study on the Discharge Characteristics of an Ac PDP with the Variation of Scan Electrode Driver (PDP 스캔 전극 구동방식에 따른 방전 특성의 변화에 관한 연구)

  • Kim, Joong-Kyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.8
    • /
    • pp.13-18
    • /
    • 2005
  • The variation of discharge characteristics of an ac PDP was observed with the charge of scan electrode driving circuit. Conventional scan electrode driving circuit provides two switches per one scan line, and the suggested one can be constituted by one switch per one scan line with the consideration of capacitive load characteristic of an ac PDP. To verify the workability of the suggested scheme, the performances of the ac PDP was investigated. The dynamic voltage margin was slightly decreased with the adoption of the suggested scheme, which is estimated to result from the misfiring of unselected discharge cells due to the deformation of voltage level of the neighboring scan electrode. In the observation of the delay characteristics of addressing discharge, the performances of the conventional circuit and the suggested one are assumed to be equivalent.

A Case of Primary Cutaneous Adenoid Cystic Carcinoma at the Genital Area (외음부에 발생한 원발성 피부 선상 낭종성 암의 치험례)

  • Jeong, Hoi Joon;Son, Dae Gu;Kwon, Sun Young
    • Archives of Plastic Surgery
    • /
    • v.35 no.3
    • /
    • pp.333-336
    • /
    • 2008
  • Purpose: Adenoid cystic carcinoma is a rare type of eccrine sweat gland carcinoma. Although it is mostly known as a neoplasm of the salivary gland, it could occur as a primary skin tumor. We present a patient with a primary cutaneous adenoid cystic carcinoma at the genital area. Methods: A 60-year-old man had a slowly growing 1 cm sized single tender mass near the left scrotum and he underwent excisional biopsy at a local clinic. A diagnosis of adenoid cystic carcinoma was made and thus he was transferred to our hospital. In physical examination, other specific findings were not detected except a linear scar caused by a previous skin biopsy near the left scrotum. In CT scan, PET-CT scan and endoscopy, there was no evidence of neoplasm in other organs. It was diagnosed as the primary cutaneous adenoid cystic carcinoma and then wide excisions were performed including total 4.5 cm margin of normal skin. Results: Microscopic findings revealed proliferation of tumor cell islands with cribriform or tubular patterns containing several round, pseudocystic structures. The tumor cells showed basaloid cells with uniform and small nuclei. Tumor cells infiltrated into the dermis and upper portion of subcutaneous tissue. There was multifocal perineural invasion of tumor cells. In postoperative 6 months, we found no recurrence and other complications. Conclusion: Herein we found a rare case of primary cutaneous adenoid cystic carcinoma at the genital area.

Electrohydrodynamic Continuous Jet Printing of Ni Ink for Crystalline Silicon Solar Cells (전기 수력학 인쇄공정을 이용한 실리콘 태양전지 전극용 Ni 잉크 제조 및 인쇄 공정 연구)

  • Lee, Youngwoo;Kim, Jihoon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.9
    • /
    • pp.593-597
    • /
    • 2015
  • Ni ink for electrohydrodynamic (EHD) continuous jet printing has been developed by using Ni nanoparticles mixed with conhesiveness provider. EHD continuous jet printing was used in order to realize $20{\mu}m$ pattern width. Ink stability was investigated by using Turbi-scan which monitors agglomeration and precipitation of nanoparticles in the ink for three days. The Turbi-scan results showed that the formulated Ni ink had been stable for 3 days without any indication of precipitation across the entire ink. Antireflection coating (ARC) layer in crystalline solar cell wafers was removed by laser ablation technique leading to the formation of 84 grooves where the Ni ink was printed by EHD continuous jet printing. The printability and microstructure of EHD-jet-printed Ni lines were investigated by using optical and electron microscopes. 84 Ni lines with the width less than $20{\mu}m$ were successfully printed by one-time printing without any misalignment and fill the laser-ablated ARC grooves.

Objective measurement of characteristics of white pan bread using a commercial korean wheat flour (상업용 우리밀을 이용한 식빵 특성의 객관적 측정)

  • 이광석;노완섭
    • Korean journal of food and cookery science
    • /
    • v.18 no.2
    • /
    • pp.206-210
    • /
    • 2002
  • The bread qualities were analyzed objectively by using CrumbScan software. Samples were prepared at the same conditions of mixing, fermentation, and baking time except the amount of Korean wheat flour (KWF). The bread volume was increased with increasing KWF, and the maximum volume was attained in the product of 20% KWF. Although the products of 20% and 30% KWF showed the same thickness of the crust, the crust was thinner than control when KWF was added. The size (fineness) and shape (elongation) of crumb cells were larger and rounder than control due to the low degree of elasticity of the KWF-added dough. Among the samples, the product with 20% KWF showed the most even distribution of crumb cells around the sliced area. The precise determination of external and internal characteristics of the bread was possible with Crumbscan, suggesting the possibility of developing industrial standards for bread.

ZNF435, a Novel Human SCAN-containing Zinc Finger Protein, Inhibits AP-1-mediated Transcriptional Activation

  • Gu, Xing;Zheng, Mei;Fei, Xiangwei;Yang, Zhenxing;Li, Fan;Ji, Chaoneng;Xie, Yi;Mao, Yumin
    • Molecules and Cells
    • /
    • v.23 no.3
    • /
    • pp.316-322
    • /
    • 2007
  • Zinc finger transcription factor genes are a significant fraction of the genes in the vertebrate genome. Here we report the isolation and characterization of a human zinc finger-containing gene, ZNF435, from a fetal brain cDNA library. ZNF435 cDNA is 1290 base pairs in length and contains an open reading frame encoding 349 amino acids with four C2H2-type zinc fingers at its carboxyl terminus and a SCAN motif at its amino terminus. RT-PCR results showed that ZNF435 was expressed in all tested tissues. A ZNF435-GFP fusion protein was located in the nucleus and the four zinc fingers acted as nuclear localization signals (NLSs). ZNF435 was found to be capable of homo-association, and this effect was independent of its zinc fingers. Furthermore, ZNF435 proved to be a transcription repressor as its overexpression in AD293 cells inhibited the transcriptional activities of AP-1.

Autologous Bone Marrow Cell Transplantation Combined with Off-pump Coronary Artery Bypass Grafting in Ischemic Myocardium (허혈성 심근에 관상동맥우회술과 병행한 자가 골수줄기세포 이식)

  • 김현옥;곽영란;강석민;장양수;임상현;안지영;이창영;강면식;유경종
    • Journal of Chest Surgery
    • /
    • v.37 no.7
    • /
    • pp.547-552
    • /
    • 2004
  • Recently, autologous bone marrow cell transplantation (CTx) for angiogenesis and myogenesis in ischemic myocardium has been extensively investigated to improve heart functions. This study was designed to evaluate the effects of CTx with off-pump coronary artery bypass grafting (OPCAB) in patients who were not feasible for complete revascularization. Material and Method: Four male patients underwent CTx and OPCAB simultaneously. Bone marrow was aspirated from iliac bone. Mean 1.5 ${\times}$ 10$^{9}$ mononuclear cells including mean 6.7 ${\times}$ 10$^{6}$ CD34 + cells and 3.7 ${\times}$ 10$^{6}$ AC133 + cells were obtained and concentrated with 10 cc. These cells were transplanted into non-graftable ischemic myocardium after OPCAB. The heart function of all patients were evaluated using the MIBI scan, echocardiogram and MRI preoperatively. The effects of CTx was evaluated using MIBI scan and echocardiogram at 1 month postoperatively. Result: An average of 2 grafts were bypassed to left anterior descending artery territory. Other territories were transplanted with isolated mononuclear cell. All patients had uncomplicated postoperative course. After 1 month follow up, there were improvement in symptom, ejection fraction (from 49% to 55%) on echocardiogram and myocardial perfusion on MIBI scan in all patients. Conclusion: These preliminary data showed improvement of heart function and myocardial perfusion and also showed the feasibility and safety of combined therapy with OPCAB and CTx in ischemic myocardium. However, the effectiveness of CTx alone cannot be readily assessed. Further randomized, controlled studies are required to evaluate the effectiveness of CTx alone.

Inflammation Scan Using $^{99m}Tc-HMPAO$ Labelled Leukocytes ($^{99m}Tc-HMPAO$를 이용한 자가백혈구표지 및 그를 이용한 염증병소의 스캔)

  • Yang, Woo-Jin;Chung, Soo-Kyo;Shinn, Kyung-Sub;Bahk, Yong-Whee;Kim, Hoon-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.2
    • /
    • pp.219-223
    • /
    • 1989
  • Inflammation scan using radiolabelled leukocytes has high sensitivity and specificity. Several methods for labelling leukocytes have been evaluated using P-32 diisopropyl fluorophosphate (DFP-32), H-3 thymidine, Cr-51 chromate, Ga-67 citrate and Tc-99m-sulfur colloid. In-111-oxine has proved so far to be the most reliable agent for labelling leukocytes. In-111-oxine is, however, expensive, not easily available when needed, and its radiation dose to leukocytes is relatively high. Moreover, resolution of the resultant image is relatively poor. Tc-99m is still the agent of choice because of, as compared with the indium, its favorable physical characteristics, lower cost and availability. Now the technique for labelling the leukocytes with technetium is successfully obtained using the lipophilic HAPAO with higher efficiency for granulocytes than for other cells. With this technique it is possible to label leukocytes in plasma to improve the viability of the leukocytes. Inflammation scan using Tc-99m-HMPAO has been evaluated in several laboratories, and difference in methods for separation and labelling accounts for difference in efficiency, viability and biodistribution of the labelled leukocytes. We performed inflammation scan using leukocytes labelled with Tc-99m-HMPAO in three dogs 24 hours after inoculation of live E. Coli and A. Aureus in their right abdominal wall. We separated mixed leukocytes by simple sedimentation using 6% hetastarch (HES) and labelled the leukocytes with Tc-99m-HMPAO in 20% cell free plama diluted with phosphate buffer solution(Fig. 1). Uptake was high in the liver and spleen but is was minimal in the lungs on whole body scan. Kidneys and intestine showed minimal activity although it was high in the urinary bladder(Fig. 2). Uptake of labelled leukocytes in the inflammation site was do(mite on 2 hour-postinjection scan and abscess was clearly delineated on 24 hour-delayed scan with high target-to-nontarget ratio(Fig. 3, 4). Inflammation scan using mixed leukocytes labelled with Tc-99m-HMPAO is very sensitive and specific in early detection of inflammation.

  • PDF

A Study on the Compensation of Temperature-Dependent Misfiring in AC PDP by the progressively increasing Address Voltage Method (AC PDP의 순차 증가 Address 전압 방식에 의한 고온 오방전 대책에 관한 연구)

  • Kim, J.Y.;Lee, S.J.;Kwon, B.D.;Kim, D.H.;Lee, H.J.;Park, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1623-1627
    • /
    • 2002
  • If the ambient temperature rises in AC PDP, some of the discharged cells arc turned off because of the addressing failure. Particularly, the addressing failure at the last scan line is more serious than at the first scan line. The failure is accompanied with delay of the address discharge and reduction of total charge involved. In order to compensate this kind of misfiling, the progressively increasing address voltage waveform is used instead of constant one. In this method, we found that the total charge and address time at the last scan line are similar to those of the first line. As a result, we can have stable discharge without misfiring even at the high ambient temperature.

  • PDF

A study on the compensation of misfiring by the method of ramp address voltage in AC PDP (AC PDP의 경사형 Address 전압 인가 방식에 의한 오방전 보상에 관한 연구)

  • Kim, J.Y.;Lee, S.J.;Kwon, B.D.;Kim, D.H.;Lee, H.J.;Park, J.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.149-152
    • /
    • 2002
  • If the ambient temperature rises for AC PDP, some of the discharge cells are turned off because of the misfiring during address period. Particularly, the misfiring of the 'last scan line is more serious than that of the first. In order to compensate the misfiring in such that case, different addressing voltage is applied at each cell such as progressively increasing pulse voltage instead of constant one. As a result, the addressing time and discharge charge of the last scan line have become similar to those of the first scan line and the phenomenon of misfiring has disappeared.

  • PDF