• Title/Summary/Keyword: Scale-down model

Search Result 221, Processing Time 0.026 seconds

An Experimental Study on Flow Structure inside a Display Cooler Using PIV Techniques (PIV기법을 이용한 전시용 냉장기의 내부 유동장 측정)

  • Park, Cheol-Woo;Baek, In-Je
    • Journal of the Korean Society of Visualization
    • /
    • v.5 no.2
    • /
    • pp.48-55
    • /
    • 2007
  • Flow structure inside a refrigerating compartment of a scale-down display cooler model was investigated experimentally by using PIV (particle image velocimetry) method, a reliable velocity field measurement technique, in the present study. In addition, we also carried out flow visualization regarding flow structure and particle movement inside a display cooler by using a tracer method. As a result, the mean velocity field measurement shows a large scale vortical flow structure inside a refrigerating compartment due to strong entrainment flow, going through a base plate open gaps.

Time Resolved Infrared Spectroscopy of Electro-optic Switching of 5CB

  • Jang, Won-Gun
    • Journal of Information Display
    • /
    • v.5 no.1
    • /
    • pp.34-40
    • /
    • 2004
  • Time resolved infrared IR absorption spectroscopy is carried out to investigate the dynamics of electric field induced reorientation of the biphenyl molecular core and alkyl tail sub-fragments of the nematic liquid crystal 5CB (4-pentyl-4-cyano-biphenyl). The planar to homeotropic transition for high pre-tilt planar aligned cells, is studied for switching times ranging from 200 ${\mu}sec$ down to 80 ${\mu}sec$, the latter a factor of 1000 times faster than any previous nematic IR study. The reorientation rates of the core and tail are found to be the same to within experimental error and scale inversely with applied field squared, as expected for the balance of field and viscous torques. Thus any molecular conformation change during switching must relax on a shorter time scale. A simple model shows that no substantial differences exist between the reorientational dynamics of the tails and cores on the time scales longer than on the order of 10 ${\mu}s$.

A Study on the Prediction of the Bow Form Design for Icebreakers (영해용선박의 선수형상 설계추정에 관한 연구)

  • 고상룡;박명규
    • Journal of the Korean Institute of Navigation
    • /
    • v.15 no.3
    • /
    • pp.73-97
    • /
    • 1991
  • The analysis and investigation are described for White's[2] equations compared to the equations of Runeburg[3] and Milano[5] for continuous icebreaking mode, Tunik[8-1] and Ghoneim[8-2] for ramming icebreaking mode. Calculation results compare reasonably well with published model-scale and full-scale icebreaker data by Baker[1] and Dick[11]. During continuous and ramming mode operation, using characteristics of an incebreaker, down ward force on ice and standard ice thickness broken are predicted. Additionally draft, trim and extraction difficulty are also predicted. The bow part line of an icebreakin $g^{ply}$ vessel is designed aiming to maximize the ice breaking capabiltiy as following conditions-low bow angle[20 degrees] at designed waterline, small spread angle complement [6 degrees] at designed waterline, small spread angle complement [6 degrees] and high propeller thrust [220tons]. with plow, two reamers and wave type bumper.

  • PDF

Numerical Analysis of Ventilation Effectiveness using Turbulent Airflow Modeling (난류유동해석을 통한 환기효율의 수치해석적 연구)

  • Han, H.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.4
    • /
    • pp.253-262
    • /
    • 1992
  • A numerical procedure is introduced to calculate local ventilation effectiveness using the definitions of local decay rate and local mean age. A low Reynolds number $k-{\varepsilon}$ model is implemented to calculate steady state turbulent velocity distributions, and a step-down method is used to calculate transient concentration distributions. Simulations are carried out for several different values of air change rates and several different diffuser angles in a two-dimensional model of a half scale office room. The results show that the local ventilation effectiveness within a room could vary significantly from one location to another. The nominal air change rate based on the assumption of complete mixing of room air does not provide the local ventilation effectiveness information. It is numerically proved that the local mean age distribution obtained from the transient calculation is equivalent to the steady state concentration distribution with homogeneously distributed contaminant sources.

  • PDF

Estimation Modelling of Energy Consumption and Anti-greening Impacts in Large-Scale Wired Access Networks (대규모 유선 액세스 네트워크 환경에서 에너지 소모량과 안티그리닝 영향도 추정 모델링 기법)

  • Suh, Yuhwa;Kim, Kiyoung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.8
    • /
    • pp.928-941
    • /
    • 2016
  • Energy consumption of today's wired data networks is driven by access networks. Today, green networking has become a issue to reduce energy wastes and $CO_2$ emission by adding energy managing mechanism to wired data networks. However, energy consumption and environmental impacts of wired access networks are largely unknown. In addition, there is a lack of general and quantitative valuation basis of energy use of large-scale access networks and $CO_2$ emissions from them. This paper compared and analyzed limits of existing models estimating energy consumption of access networks and it proposed a model to estimate energy consumption of large-scale access networks by top-down approach. In addition, this work presented models that assess environmental(anti-greening) impacts of access networks using results from our models. The performance evaluation of the proposed models are achieved by comparing with previous models based on existing investigated materials and actual measured values in accordance with real cases.

A Study on the Pollutant Dispersion over a Mountain Valley Region (I) : Wind Tunnel Experiments (산악 계곡지형에서의 오염확산에 관한 연구(I) :풍동실험)

  • Yoo Seong-Yeon;Shim Woo-Sup;Kim Seogcheol
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.11
    • /
    • pp.1050-1059
    • /
    • 2005
  • Heat and $SF_6$ gas dispersions over a complex terrain were investigated using wind tunnel. The wind speed, temperature and concentration profiles were measured for the 1/1000 scale complicated terrain model in an Eiffel type boundary layer wind tunnel with test section of 2.5m in height and 4.5m in width. The scale model was mounted on the top of a plate which can rotate with respect to the approaching wind. Dispersion processes from a continuous emission source driven by various wind direction were investigated, including plume climbing over the steep up-slope of the mountain and down-spreading toward the lower level of the valley. Extensive dispersion experiment data (wind speeds and concentration profiles) were provided for verification and validation of dispersion models. Under the identical flow and emission conditions, the independently measured profiles of the temperature and $SF_6$ concentration showed an excellent agreement which ensured the credibility of the results.

A FEA for the Stiffness Estimation of the Transverse Kong-Po in Dae-Woong-Jeon of Bongjeong-Sa (봉정사 대웅전 보 방향 공포의 강성산정을 위한 유한요소해석)

  • Jung Sung-Jin;Hong Sung-Gul;Kim Nam-Hee;Lee Young-Wook;Hwang Jong-Kook;Bae Byoung-Sun
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.405-412
    • /
    • 2006
  • Among the various problems involved in the structural analysis of the Korean traditional wooden structure, the analytical model for the Kong-Po is controversial subject as usual. While some experiments are tried for establishing the basis of analytical models, most of these experiments are performed using scale down specimens. So, it is not possible to apply these experimental results to structural analysis of Korean traditional wooden structure directly. A numerical study for analogizing the stiffness of full scale Kong-Po structure is performed on the basis of experimental specimen. Some parameter studies using finite element method are made in this study. The finite element analysis used in this study is geometric material nonlinear analysis. The stiffness of Kong-Po structure found out in this study can be used for modelling the joints of the Korean traditional wood structure in frame analysis.

  • PDF

Watershed Scale Management Techniques of the Pollutants from Small Scale Livestock Ranches - Buffer Zone Selection for Natural Purification - (농촌 소유역 축산폐수의 유역관리기법 개발 - 자연정화처리를 위한 완충대 적지분석 -)

  • Kim, Seong-Joon;Lee, Nam-Ho;Yoon, Kwang-Sik;Hong, Seong-Gu;Lee, Yun-Ah
    • Journal of Korean Society of Rural Planning
    • /
    • v.6 no.2 s.12
    • /
    • pp.43-49
    • /
    • 2000
  • Buffer zone selection technique for natural purification of livestock wastewater within a small agricultural watershed was developed using Geographic Information Systems. The technique was applied to $4.12\;km^2$ watershed located in Gosan-myun, Ansung-gun which have 20 livestock farmhouses. As a necessary data for selecting process, feedlot site map, digital Elevation Model (DEM), stream network, soil and land use map were prepared. By using these data, wastewater moving-path tracing program from each feedlot to the stream was developed to get the basic topographic factors; average slope through the paths, distance to the nearest stream and watershed outlet. To identify the vulnerable feedlots for storm event, the grid-based storm runoff model (Kim, 1998; Kim et al., 1998) was adopted. The result helps to narrow down the suitable area of buffer zone, and finally by using subjective but persuasive conditions related to elevation, slope and land use, the suitable buffer zones were selected.

  • PDF

An Experimental Study on the Analyze the Pressure Difference in case of Fire in Vertical Space of High-Rise Buildings (고층건축물 수직공간의 화재 시 압력차 분석을 위한 실험적 연구)

  • Huh, Yerim;Kim, HyeWon;Jin, SeungHyeon;Kwon, YoungJin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.111-112
    • /
    • 2020
  • As buildings in South Korea become more skyscrapers, the risk of fire is also emerging. Thus, regulations, regulations, and guidelines are being improved to prevent the spread of smoke in the event of a fire in high-rise buildings, but research on smoke flow and pressure distribution in vertical spaces is insufficient. Therefore, in this study, the temperature of each floor in the vertical space according to the size of the fire is measured through the miniature model experiment, and the pressure difference is calculated to establish the basic data for the improvement of the performance of domestic air supply facilities in the future. Thus, a scale model of one-sixth the size of the actual building was produced to measure the temperature, and the pressure difference was derived by substituting the value for the expression. The pressure difference varies depending on the size of the cause of the fire, and it is believed that the differential pressure and conditions of the building should be taken into account before calculating the supply volume for the analysis of the pressure difference according to the size of the cause of the fire in the event of fire.

  • PDF

Analysis of operation performance of PHILS-based superconducting current limiter connected to MVDC system

  • Seok-Ju Lee;Jae In Lee
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.4
    • /
    • pp.54-59
    • /
    • 2023
  • In this paper, we analyze experimental results by applying the PHILS model to a lab-scale superconducting current limiter system for its actual application in medium-voltage direct current (MVDC) systems. Superconducting current limiters exhibit effective current-limiting performance in circuit breaker operations, particularly in limiting large fault currents within a short period, addressing the challenges posed by the increasing use of renewable energy and the integration of DC medium-voltage distribution systems. The development of such superconducting current limiters faces various technical and cost disadvantages, especially when applying a medium-voltage 35kV level system, which is intended for future introduction. The proven lab-scale superconducting current limiter system and the PHILS model are combined and integrated into the actual system. Our plan involves analyzing the limiter's performance, assessing its impact on the system, and preparing for its application in future medium-voltage systems. Utilizing RTDS, a simulation was conducted by connecting actual scaled-down equipment and systems, with the analysis results presented.