Development of small constructed wetland for urban and roadside areas (도시 및 도로 조경공간을 활용한 소규모 인공습지 조성 기술)

  • Kang, Chang-Guk;Maniquiz, Marla C.;Son, Young-Gyu;Cho, Hye-Jin;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.13 no.2
    • /
    • pp.231-242
    • /
    • 2011
  • Recently, the green spaces in the urban areas were greatly reduced due to urbanization and industrialization. As urban structures such as roads and buildings are built, the amount of impervious area within a watershed increases. High impervious surfaces are the common causes of high runoff volumes as the soil infiltration capacity decreases and the volume and rate of runoff increase thereby decreasing the groundwater recharge. These effects are causing many environmental problems, such as floods and droughts, climate change, heat island phenomenon, drying streams, etc. Most cities attempted to reduce sewer overflows by separating combined sewers, expanding treatment capacity or storage within the sewer system, or by replacing broken or decaying pipes. However, these practices can be enormously expensive than combined sewer overflows. Therefore, in order to improve these practices, alternative methods should be undertaken. A new approach termed as "Low Impact Development (LID)" technology is currently applied in developed countries around the world. The purpose of this study was to effectively manage runoff by adopting the LID techniques. Small Constructed Wetland(Horizontal Subsurface Flow, HSSF) Pilot-scale reactors were made in which monitoring and experiments were performed to investigate the efficiency of the system in removing pollutants from runoff. Based on the results of the Pilot-plant experiments, TSS, $COD_{Cr}$, TN, TP, Total Pb removal efficiency were 95, 82, 35, 91 and 57%, respectively. Most of the pollutants were reduced after passing the settling tank and the vertical filter media. The results of this study can contribute to the conservation of aquatic ecosystems and restoration of natural water cycle in the urban areas.

A Study on the Application of the Solar Energy Seasonal Storage System Using Sea water Heat Source in the Buildings (해수냉열원을 이용한 태양열계간축열시스템의 건물냉방 적용에 관한 연구)

  • Kim, Myung-Rae;Yoon, Jae-Ock
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.56-61
    • /
    • 2009
  • Paradigm depending only on fossil fuel for building heat source is rapidly changing. Accelerating the change, as it has been known, is obligation for reducing green house gas coming from use of fossil fuel, i.e. reaction to United Nations Framework Convention on Climate Change. In addition, factors such as high oil price, unstable supply, weapon of petroleum and oil peak, by replacing fossil fuel, contributes to advance of environmental friendly renewable energy which can be continuously reusable. Therefore, current new energy policies, beyond enhancing effectiveness of heat using equipments, are to make best efforts for national competitiveness. Our country supports 11 areas for new renewable energy including sun light, solar heat and wind power. Among those areas, ocean thermal energy specifies tidal power generation using tide of sea, wave and temperature differences, wave power generation and thermal power generation. But heat use of heat source from sea water itself has been excluded as non-utilized energy. In the future, sea water heat source which has not been used so far will be required to be specified as new renewable energy. This research is to survey local heating system in Europe using sea water, central solar heating plants, seasonal thermal energy store and to analyze large scale central solar heating plants in German. Seasonal thermal energy store necessarily need to be equipped with large scale thermal energy store. Currently operating central solar heating system is a effective method which significantly enhances sharing rate of solar heat in a way that stores excessive heat generating in summer and then replenish insufficient heat for winter. Construction cost for this system is primarily dependent on large scale seasonal heat store and this high priced heat store merely plays its role once per year. Since our country is faced with 3 directional sea, active research and development for using sea water heat as cooling and heating heat source is required for seashore villages and building units. This research suggests how to utilize new energy in a way that stores cooling heat of sea water into seasonal thermal energy store when temperature of sea water is its lowest temperature in February based on West Sea and then uses it as cooling heat source when cooling is necessary. Since this method utilizes seasonal thermal energy store from existing central solar heating plant for heating and cooling purpose respectively twice per year maximizing energy efficiency by achieving 2 seasonal thermal energy store, active research and development is necessarily required for the future.

  • PDF

A Study on Comparative Analysis of Socio-economic Impact Assessment Methods on Climate Change and Necessity of Application for Water Management (기후변화 대응을 위한 발전소 온배수 활용 양식업 경제성 분석)

  • Lee, Sangsin;Kim, Shang Moon;Um, Gi Jeung
    • Journal of Korean Society of societal Security
    • /
    • v.4 no.2
    • /
    • pp.73-78
    • /
    • 2011
  • In order to resolve the problem of change in global climate which is worsening as days go by and to preemptively cope with strengthened restriction on carbon emission, the government enacted 'Framework Act on Low Carbon Green Growth' in 2010 and selected green technology and green industry as new national growth engines. For this reason, the necessity to use the un-utilized waste heat across the whole industrial system has become an issue, and studies on and applications of recycling in the agricultural and fishery fields such as cultivation of tropical crops and flatfishes by utilizing the waste heat and thermal effluent generated by large industrial complexes including power plants are being actively carried out. In this study, we looked into the domestic and overseas examples of having utilized waste heat abandoned in the form of power plant thermal effluent, and carried out economic efficiency evaluation of sturgeon aquaculture utilizing thermal effluent of Yeongwol LNG Combined Cycle Power Plant in Gangwon-do. In this analysis, we analyzed the economic efficiency of a model business plan divided into three steps, starting from a small scale in order to minimize the investment risk and financial burden, which is then gradually expanded. The business operation period was assumed to be 10 years (2012~2021), and the NVP (Net Present Value) and economic efficiency (B/C) for the operation period (10 years) were estimated for different loan size by dividing the size of external loan by stage into 80% and 40% based on the basic statistics secured through a site survey. Through the result of analysis, we can see that reducing the size of the external loan is an important factor in securing greater economic efficiency as, while the B/C is 1.79 in the case the external loan is 80% of the total investment, it is presumed to be improved to 1.81 when the loan is 40%. As the findings of this study showed that the economic efficiency of sturgeon aquaculture utilizing thermal effluent of power plant can be secured, it is presumed that regional development project items with high added value can be derived though this, and, in addition, this study will greatly contribute to reinforcement of the capability of local governments to cope with climate change.

  • PDF

Decreased Nocturnal Blood Pressure Dipping in Patients with Periodic Limb Movements in Sleep (수면중 주기성 사지 운동에서 나타나는 야간 혈압 강하의 감소)

  • Lee, Mi Hyun;Choi, Jae-Won;Oh, Seong Min;Lee, Yu Jin
    • Sleep Medicine and Psychophysiology
    • /
    • v.25 no.2
    • /
    • pp.51-57
    • /
    • 2018
  • Objectives: Previous studies have shown that periodic limb movements in sleep (PLMS) could be one of risk factors for cardiovascular morbidity. The purpose of this study was to investigate the association between PLMS and blood pressure changes during sleep. Methods: We analyzed data from 358 adults (176 men and 182 women) aged 18 years and older who were free from sleep apnea syndrome (Respiratory Disturbance Index < 5) and sleep disorders such as REM sleep behavior disorder or narcolepsy. Demographic characteristics, polysomnography records, and clinical variable data including blood pressure, body mass index, alcohol, smoking, and current medications were collected. In addition, self-report questionnaires including the Beck Depression Index, Epworth Sleepiness Scale and Pittsburgh Sleep Quality Index were completed. Blood pressure change from bedtime to awakening was compared between the two periodic limb movement index (PLMI) groups [low PLMI ($PLMI{\leq}15$) and high PLMI (PLMI > 15)]. Blood pressure change patterns were compared using repeated measures analysis of variance. Results: Systolic blood pressure in the high PLMI group was lower than that in the low PLMI group (p = 0.036). These results were also significant when adjusted for gender and age, but were not statistically significant when adjusted for BMI, alcohol, smoking, anti-hypertension medication use and sleep efficiency (p = 0.098). Systolic blood pressure dropped by 9.7 mm Hg in the low PLMI group, and systolic blood pressure in the high PLMI group dropped by 2.9 mm Hg. There was a significant difference in delta systolic blood pressure after sleep between the two groups in women when adjusted for age, BMI, alcohol, smoking, antihypertensive medication use and sleep efficiency (p = 0.023). Conclusion: PLMS was significantly associated with a decreasing pattern in nocturnal BP during sleep, and this association remained significant in women when adjusted for age, BMI, alcohol, smoking, antihypertension medication use and sleep efficiency related to blood pressure. We suggest that PLMS may be associated with cardiovascular morbidity.

What Happened to Efficiency and Competition after Bank Mergers and Consolidation in Korea? (한국 은행들의 합병, 통합 이후 효율성과 경쟁도는 개선되었는가?)

  • Park, Kang H.
    • KDI Journal of Economic Policy
    • /
    • v.33 no.3
    • /
    • pp.33-55
    • /
    • 2011
  • Market concentration in the Korean banking industry has markedly increased since the financial crisis of 1997-1998 because of M&As, P&As, and consolidation of banks. With this change, there has been a growing concern over market power in the Korean banking sector. We examine the effects of market concentration on bank efficiency and competition for the period of 1992-2006. Three different indicators of bank inefficiency are used in this study, including X-inefficiency that is derived from the directional technology distance function. The level of competition is measured by both the H-statistic of the Panzar-Rosse model and the level of the net interest margin and its standard deviation. Empirical results indicate that market concentration has not improved bank efficiency through scale economies or scope economies. Instead, recent mergers, acquisitions and consolidation of banks resulted in an increase in inefficiency measured by the three different indicators: X-inefficiency, labor inefficiency and asset inefficiency. While an increase in market share of individual banks improved bank efficiency, an increase in the overall market concentration ratio resulted in lower efficiency. Our study also finds that the Korean banking sector has been monopolistically competitive throughout the sample period except for the crisis period according to the H-statistic. Although an increase in market concentration ratio has not changed the overall level of bank competition, it has a positive significant effect on the level of the average interest margin.

  • PDF

Combustion Characteristics of a Hot Water Boiler System Convertibly Fueled by Rice Husk and Heavy Oil - Heavy Oil Combustion Characteristics -

  • Kim, Myoung Ho;Kim, Dong Sun;Park, Seung Je
    • Journal of Biosystems Engineering
    • /
    • v.38 no.4
    • /
    • pp.306-311
    • /
    • 2013
  • Purpose: With the ever-rising energy prices, thermal energy heavily consuming facilities of the agricultural sector such as commercialized greenhouses and large-scale Rice Processing Complexes (RPCs) need to cut down their energy cost if they must run profitable businesses continually. One possible way to reduce their energy cost is to utilize combustible agricultural by-products or low-price oil instead of light oil as the fuel for their boiler systems. This study aims to analyze the heavy oil combustion characteristics of a newly developed hot water boiler system that can use both rice husk and heavy oil as its fuel convertibly. Methods: Heavy oil combustion experiments were conducted in this study employing four fuel feed rates (7.6, 8.5, 9.5, 11.4 $l/h$) at a combustion furnace vacuum pressure of 500 Pa and with four combustion furnace vacuum pressures (375, 500, 625, 750 Pa) at fuel feed rates of 9.5 and 11.4 $l/h$. Temperatures at five locations inside the combustion furnace and 20 additional locations throughout the whole hot water boiler system were measured to ascertain the combustion characteristics of the heavy oil. From the temperature measurement data, the thermal efficiency of the system was calculated. Flue gas smoke density and concentrations of air-polluting components in the flue gas were also measured by a gas analyzer. Results: As the fuel feed rate or combustion furnace vacuum pressure increased, the average temperature in the combustion furnace decreased but the thermal efficiency of the system showed no distinctive change. On the other hand, the thermal efficiency of the system was inversely proportionally to the vacuum level in the furnace. For all experimental conditions, the thermal efficiency remained in the range of 80.1-89.6%. The CO concentration in the flue gas was negligibly low. The NO and $SO_2$ concentration as well as the smoke density met the legal requirements. Conclusions: Considering the combustion temperature characteristics, thermal efficiency, and flue gas composition, the optimal combustion condition of the system seemed to be either the fuel feed rate of 9.5 $l/h$ with a combustion furnace vacuum pressure of 375 Pa or a fuel feed rate of 11.4 $l/h$ with a furnace vacuum pressure between 500 Pa and 625 Pa.

Effect of Ultrasonic Irradiation on Ozone Nanobubble Process for Phenol Degradation (페놀 분해를 위한 오존 나노기포 공정에서 초음파 조사의 영향)

  • Lee, Sangbin;Park, Jae-Woo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.23 no.3
    • /
    • pp.23-29
    • /
    • 2022
  • In this study, we investigated the ozone nanobubble process in which nanobubble and ultrasonic cavitation were applied simultaneously to improve the dissolution and self-decomposition of ozone. To confirm the organic decomposition efficiency of the process, a 200 mm × 200 mm × 300 mm scale reactor was designed and phenol decomposition experiments were conducted. The use of nanobubble was 2.07 times higher than the conventional ozone aeration in the 60 minutes reaction and effectively improved the dissolution efficiency of ozone. Ultrasonic irradiation increased phenol degradation by 36% with nanobubbles, and dissolved ozone concentration was lowered due to the promotion of ozone self-decomposition. The higher the ultrasonic power was, the higher the phenol degradation efficiency. The decomposition efficiency of phenol was the highest at 132 kHz. The ozone nanobubble process showed better decomposition efficiency at high pH like conventional ozone processes but achieved 100% decomposition of phenol after 60 minutes reaction even at neutral conditions. The effect by pH was less than that of the conventional ozone process because of self-decomposition promotion. To confirm the change in bubble properties by ultrasonic irradiation, a Zetasizer was used to measure the bubbles' size and zeta potential analysis. Ultrasonic irradiation reduced the average size of the bubbles by 11% and strengthened the negative charge of the bubble surface, positively affecting the gas transfer of the ozone nanobubble and the efficiency of the radical production.

Analysis of the Structural Characteristics of the Chungnam Display Industry (충남 디스플레이 산업의 구조적 특성 분석)

  • Kim, Dae-Jung;Ko, Kyoung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.620-626
    • /
    • 2021
  • The purpose of this study is to examine the characteristics and industrial structure and to present a future vision through analysis of industrial agglomeration, growth, and industrial efficiency targeting the Chungnam display industry nurtured by regional industrial policies since 2002. The industrial scale and aggregate status were analyzed through the business scale quotient and location quotient, and the growth and pace of structural change in the industry were analyzed through the industrial growth rate and change of industrial structure. Analysis results found the display industry shows its solid status based on industrial agglomeration. The RLQ, added value ratio, and employment coefficient have a relatively high comparative advantage. However, the growth rate has declined, and the pace of structural change has become lower. The regional competitiveness has been deteriorating. It is necessary to develop strategies to help the industry evolve into a convergence display industry to secure competitiveness by forming value chains. The regional industrial policy 'Regional Innovation Growth Plan' should be utilized to foster local industries that consider the regional characteristics and development directions and to promote the shared growth of related subsidiary industries through fostering specialized complexes for materials, parts, and equipment.

The Study of the Integrated Technology of the Dual Fluidized-bed Gasification for Producing Medium Heating Value Syngas (중발열량 합성가스 생산을 위한 일체형 이중유동층 가스화 기술 연구)

  • Choi, Jae-Myeong;Kim, Jae-Min;Kim, Sung-Hyun;Son, Yang-Seung;Lee, Dong-Min;Choi, Jin-Hoon;Park, Sung-Youl;Kim, Seong-Soo
    • Clean Technology
    • /
    • v.19 no.3
    • /
    • pp.226-232
    • /
    • 2013
  • A 5 kg/hr scale integral dual fluidized-bed gasifier for producing medium heating value syngas from biomass or combustible wastes was manufactured. The effect of operating variables including gasification temperature, rate of feeding, and weight ratio of steam/feed on the behavior of the gasifier was investigated. The contents of $H_2$ and CO in syngas, flow rate of feeding, cold gas efficiency increased with the increased gasification temperature or rate of feeding, but decreased with the increased weight ratio of steam/feed within the experimental range. With wood powder as the feed, the concentrations of $H_2$ and CO in the syngas were as high as 41% and 32%, and the cold gas efficiency and lower heating value of the syngas were as high as 70.1% and $3,428kcal/Nm^3$. With food wastes as the feed, the concentrations of $H_2$ and CO in the syngas were as high as 37% and 23.9%, and the cold gas efficiency and lower heating value of the syngas were as high as 66.7% and $3,670kcal/Nm^3$.

Analysis of DITI, HRV about the Effect of Far Infrared Radiation Applied to Whole Body('On-tong Therapy') (전신 원적외선 조사요법(온통요법(溫通療法))의 치료 효과에 대한 적외선 체열 분포와 심박변이도 검사 분석)

  • Kim, Min-Young;Ahn, Ji-Yoon;Choi, Seok-Young;Hwang, Deok-Sang;Lee, Jin-Moo;Jang, Jun-Bock;Lee, Kyung-Sub;Lee, Chang-Hoon
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.26 no.4
    • /
    • pp.94-106
    • /
    • 2013
  • Objectives: The purpose of this study is to find the effect of Far Infrared Radiation (FIR) about improvement of chief complaints and health state. Methods: For this study we evaluated thermographic images, heart rate variability (HRV), visual analogue scale (VAS) score of 34 patients with various diseases. Tests were done two times, before and after treatments and we compared the test results. We used the temperature difference between CV12 and CV4, both sides of PC8, LR3 for recognizing improvement of blood circulation. We analyzed the change of complexity, stability of autonomic nervous system (ANS) by HRV test. The patients were asked to fill out questionnaire about the severity of symptoms by VAS score. Analyses were undertaken using SPSS ver.12.0.1 and p-value of < 0.05 was considered significant. Results: Statistical analysis shows that Far Infrared Radiation (FIR) had significant efficiency in increasing surface temperature and reducing VAS pain scores. In heart rate variability (HRV) test, LF/HF ratio showed tends to improve. Conclusions: The application of an FIR to whole body appears to alleviate various complaints of patients.