A Study on Energy Savings in a Network Interface Card Based on Optimization of Interrupt Coalescing (인터럽트 병합 최적화를 통한 네트워크 장치 에너지 절감 방법 연구)

  • Lee, Jaeyoul;Han, Jaeil;Kim, Young Man
    • Journal of Information Technology Services
    • /
    • v.14 no.3
    • /
    • pp.183-196
    • /
    • 2015
  • The concept of energy-efficient networking has begun to spread in the past few years, gaining increasing popularity. A common opinion among networking researchers is that the sole introduction of low consumption silicon technologies may not be enough to effectively curb energy requirements. Thus, for disruptively boosting the network energy efficiency, these hardware enhancements must be integrated with ad-hoc mechanisms that explicitly manage energy saving, by exploiting network-specific features. The IEEE 802.3az Energy Efficient Ethernet (EEE) standard is one of such efforts. EEE introduces a low power mode for the most common Ethernet physical layer standards and is expected to provide large energy savings. However, it has been shown that EEE may not achieve good energy efficiency because mode transition overheads can be significant, leading to almost full energy consumption even at low utilization levels. Coalescing techniques such as packet coalescing and interrupt coalescing were proposed to improve energy efficiency of EEE, but their implementations typically adopt a simple policy that employs a few fixed values for coalescing parameters, thus it is difficult to achieve optimal energy efficiency. The paper proposes adaptive interrupt coalescing (AIC) that adopts an optimal policy that could not only improve energy efficiency but support performance. AIC has been implemented at the sender side with the Intel 82579 network interface card (NIC) and e1000e Linux device driver. The experiments were performed at 100 M bps transfer rate and show that energy efficiency of AIC is improved in most cases despite performance consideration and in the best case can be improved up to 37% compared to that of conventional interrupt coalescing techniques.

A Study on the Performance Analysis in the Plate and Shell Heat Exchanger (판각형 열교환기 성능해석에 관한 연구)

  • Seo, M.K.;Park, J.H.;Kim, Y.S.
    • Journal of Power System Engineering
    • /
    • v.5 no.1
    • /
    • pp.35-43
    • /
    • 2001
  • Heat exchangers are called with important devices which have been widely used in industrial fields. Therefore, the design method for a heat exchanger is an important study in the aspect of energy saving. In this study, performance analyses for two types of plate and shell heat exchangers having a corrugated trapezoid shape of a chevron angle with $45^{\circ}$, were executed and compared with experiments. For this study, the operation liquids were adopted with non-phase changing water. In the analysis, ${\epsilon}-NTU$ method was used for a plate and shell heat exchanger and a program was constructed. Independent variables for a plate and shell heat exchanger are flow rate and inlet temperature. Compared with experimental data, the accuracy of the developed are ${\pm}2.5%\;and\;{\pm}5%$ at the type A and type B in the heat transfer rate, respectively. In the pressure drop, the accuracy of the proposed program for a plate and shell heat exchanger is within ${\pm}3%$ and 5% error bounds for the type A and type B, respectively.

  • PDF

A Current State of Multihousing Evaluation Based on the Construction Criteria and Performance Codes of Green Homes (친환경주택의 건설기준 및 성능규정에 의한 공동주택 평가현황에 관한 연구)

  • Lee, Seul-Bi;Yu, Ki-Hyung;Yoon, Seong-Hoon
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.113-118
    • /
    • 2015
  • Purpose: In Korea, buildings make up 20.5% (2012) of the gross national energy consumption, so they are a major target for greenhouse gas reduction. In particular, energy consumption in multihousing represents approximately 32.6% of the entire building sector. With improving energy performance being the focus, efforts are continuously being made to reinforce standards and systems in greenhouse gas reduction. This study investigated the current status of multihousing in Korea in terms of energy performance as described in the performance evaluation reports submitted (to an institution that specializes in reviewing the performance evaluation of green homes) based on the construction criteria and performance codes for green homes and examined if the evaluation criteria using related methodologies were appropriate. The results will provide helpful information for reviewing the future directions of operations and amendments to the systems. Method: The overall characteristics of the system were examined using the evaluation methodologies (and current state of revisions) of the performance codes for green homes and comparing them with similar systems. Also, the current state of application and energy performance (conducted according to the evaluation methodologies) were compared by the evaluation institution for multihousing neighborhoods that were assessed for five years from 2010 to 2014. Result: It has been confirmed that the performance codes for green homes are different from other similar systems in evaluating performances of multihousing in that they allow both quantitative and qualitative methods of evaluation, and they consider both energy and sustainability simultaneously in the evaluation. Furthermore, regarding the adoption rate of the forms for the two evaluation methods (Form 1 - quantitative and Form 2 - qualitative), the rate preferring Form 2 increased gradually in time to reach 55.3% in 2014. In analyzing the rate of overall energy reduction (submitted in Form 1) and the coefficient of thermal transmission for each part (submitted in Form 2), it was observed that the deviation between the performance submitted and the criteria decreased in line with the level of reinforcement.

Ultra-Power-Saving 2 Ports PLC Wall Switch Development (초절전형 PLC 2구 스위치 개발)

  • Han, Jae-Yong;Lee, Sun-Heum
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.11
    • /
    • pp.51-55
    • /
    • 2007
  • Generally, PLC (Power Line Communication) based home automation devices such as wall switch, walt socket, gas controller, etc, must maintain wake-up status at all time to control other electronic devices and monitor their on/off status whether they are in service or not. In order to reduce the unnecessary energy consumption during the standby mode, the new power-saving PLC 2 ports wall switch has been developed, separating PLC communication part and controller part and introducing sleep mode. In addition, to expand life cycle of PLC product and to reduce the rate of product failure in active mode, the instant controlling method in controlling process is adopted instead of the maintenance controlling method. In comparison to the earlier model, the new 2 ports PLC wall switch has reduced power by 0.95[W] less in standby mode and 3.2[W] less in active mode than the previous one.

Development of Energy Saving Aeration Panel for Aerating in Activated Sludge System (활성 슬러지조 폭기를 위한 에너지 절감형 판형 멤브레인 산기장치의 개발)

  • Kim, Ji Tae;Tak, Hyon Ki;Kim, Jong Kuk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.6
    • /
    • pp.414-420
    • /
    • 2012
  • In an effort to commercialization of energy saving aeration apparatus, panel-type aeration membranes were prepared from polyurethane sheet of J company in Korea having tensile strength higher than $400kg_f/cm^2$ with thickness of 0.5mm. Micropores of 100 m size were made by poring technique utilizing needles. From lab-tests in 450 L water tank at temperature of $20^{\circ}C$, the performance of aeration panels at 40 L/min aeration rate showed 5 mg/L DO in less than 3 minutes approaching saturation point of 8 mg/L within 8 minutes. The results show very high efficiency with $K_{La(15)}$ ($16.34hr^{-1}$), Standard oxygen transfer efficiency (SOTE 54.7%) and Standard aeration efficienct (SAE 7.88 kg/kwh). Other pilot scale test in a $2m^3$ water tank with water temperature ($19^{\circ}C$) and aeration rate (30 L/min) showed DO exceeding 5 mg/L within 8 minutes along with $K_{La(15)}$ ($5.8hr^{-1}$), SOTE (42.1%) and SAE (6.41 kg/kwh). These efficiencies represent 2~2.5 times higher than conventional aeration devices. Especially, the achievement of higher Oxygen Transfer Rate indicate higher commercial viability. Conventional aeration devices when applied to clean water and wastewater frequently cause problems due to differences in actual Oxygen Transfer Rate. Our actual tests with $40^{\circ}C$ animal farm wastewater resulted very high efficiencies with Oxygen transfer efficiency ($OTE_f$ 22.1%) and $OTE_{pw40}$ (39.6%).

Fishing performance of hull form renovated tuna purse seiner (선형개조 다랑어 선망선의 조업성능)

  • HONG, Jin-Keun;KANG, Il-Kwon;JEONG, Seong-Jae
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.51 no.3
    • /
    • pp.321-332
    • /
    • 2015
  • In an attempt to find the improvement of the fishing efficiency according to the hull form remodeling for the 3 tuna purse seiner, the Catch-Per-Unit-Effort (CPUE) for that undertaken before (2008) and after (2010) was analyzed. In addition, the CPUE of 6 similar ships operated same period and same fishing ground. As result, it came to verify that the three modified ships had a significant value on the CPUE. An another index for the improvement of fishing efficiency is the rate of reduction of fuel oil consumption for the modified ships. Fuel oil consumption per day in service speed as comparing with the original ships were reduced 2.1%, 4.0% and 5.1% on the modified ship A, B, and C respectively. And each ship's service speed was increased 1.0 kt, 0.6 kt, and 0.4 kt according to the modified ship A, B, and C in due order. In the conclusion, the remodeling job with newly equipped bulbous bow, lengthened slipway and enlarged rudder area were improved fairly much on fuel oil efficiency, the ship's speed, and in the end, that led to the improving fishing efficiency. Hence, the remodeling of tuna purse seiner come to improve not only the fishing performance, but contribute to the reduction of operating cost by saving energy for the fisheries industry.

A Study on the Characteristics of Refrigerating System according to the Condensation and Evaporation Load (응축 및 증발 부하에 따른 냉동시스템 특성에 관한 연구)

  • Choi, Seung-Il;Ji, Myoung-Kuk;Lee, Dae-Chul;Jeong, Hyo-Min;Chung, Han-Shik
    • Journal of Power System Engineering
    • /
    • v.17 no.3
    • /
    • pp.44-49
    • /
    • 2013
  • The refrigerating system are high efficiency and comfortable due to the automation of the system as well as enhance energy saving are contributing to driving system. Previous study the rotational frequency of the compressor was confined to the fixed condition have changed load of evaporator and condenser related about the refrigerator performance characteristic according to the evaporation load and condensation load change tries to be analyze through the experiment. The useful data for the economic driving of the freezing apparatus tries to be drawn. Consequently, it confirmed that refrigerant in the compressor overheated and as the evaporation load increased the specific volume was increased and the coolant circulation rate decreased. In confirmed that condensation load increased the compression ratio and discharge gas temperature increased. It reduced the low-temperature efficiency and condensation calorie and the quality factor was decreased.

Simulation of Membrane-absorption Hybrid Process for LNG-FPSO (LNG-FPSO용 막-흡수 하이브리드 공정 전산모사)

  • Min, Kwang-Joon;Cho, Habin;Kim, Jin-Kuk;Kang, Sang Wook
    • Membrane Journal
    • /
    • v.28 no.2
    • /
    • pp.90-95
    • /
    • 2018
  • A process design was performed for a removal of acid gases using membrane-absorption hybrid system in LNG-FPSO. Commercial process simulator Promax version 4.0 was utilized for comparing acid gases removal capabilities of amine absorption process and hybrid process. Simulation results show hybrid process could be small amine solvent circulate rate, energy consumption, equipment sizing compared to typical amine absorption process. As a result, hybrid process which is small footprint and energy saving process may be a good solution for the pre-treatment of natural gas in LNG-FPSO.

The Development for Blending Brake System of Electrical Multiple Unit used by Electric Brake (전기제동을 이용한 전동차의 혼합제동장치의 개발방향)

  • Lee, Woo-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2008.04c
    • /
    • pp.155-157
    • /
    • 2008
  • An electric multiple unit(EMU) consists of car body, bogie and brake equipment which is directly related to safety and performance of the motorcar. The blending brake mixed an electric brake and a friction brake is to reduce the energy by applying the restoration energy caused when the motorcar is stopped to car lines and to curtail the maintenance cost by saving the friction brake use. We have developed the advanced EMU since 2004, based on the experiences on the standard EMU in 1999, and we develop the installation which minimizes the use rate of the friction air brake by maximizing the electric brake use in the existing blending brake. We could accomplish the goal by improving the motorcar's Performance and solving the restoration energy's deficit by the friction brake. Actually, when it comes to the test results of standard EMU, except the service brake, in most conditions, we use electric brake to meet the requirements of the necessary brake power, exclusive when the motorcar leaves and stops. Therefore, in this paper, we consider the design concept of motorcar's blending brakes and suggest the way to develop the blending brake using the electric brake maximumly, which is caused by adequately controling the electric brake and the restoration brake.

  • PDF

Numerical Analysis for the Effect of Ground and Groundwater Conditions on the Performance of Ground Source Heat Pump Systems (토양 및 지하수 조건이 지열공조시스템의 성능에 미치는 영향에 관한 수치 해석적 연구)

  • Nam, Yu-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.5
    • /
    • pp.321-326
    • /
    • 2011
  • Recently, ground source heat pump (GSHP) systems have been introduced in many modem buildings which use the annually stable characteristic of underground temperature as one of the renewable energy uses. However, all of GSHP systems cannot achieve high level of energy efficiency and energy-saving, because their performance significantly depends on thermal properties of soil, the condition of groundwater, building loads, etc. In this research, the effect of thermal properties of soil on the performance of GSHP systems has been estimated by a numerical simulation which is coupled with ground heat and water transfer model, ground heat exchanger model and surface heat balance model. The thermal conductivity of soil, the type of soil and the velocity of groundwater flow were used as the calculation parameter in the simulation. A numerical model with a ground heat exchanger was used in the calculation and, their effect on the system performance was estimated through the sensitivity analysis with the developed simulation tool. In the result of simulation, it founds that the faster groundwater flow and the higher heat conductivity the ground has, the more heat exchange rate the system in the site can achieve.