• Title/Summary/Keyword: Saturation response time

Search Result 76, Processing Time 0.023 seconds

Influence of time delay and saturation capacity to the response of controlled structures under earthquake excitations

  • Pnevmatikos, Nikos G.;Gantes, Charis J.
    • Smart Structures and Systems
    • /
    • v.8 no.5
    • /
    • pp.449-470
    • /
    • 2011
  • During the last thirty years many structural control concepts have been proposed for the reduction of the structural response caused by earthquake excitations. Their research and implementation in practice have shown that seismic control of structures has a lot of potential but also many limitations. In this paper the importance of two practical issues, time delay and saturation effect, on the performance of controlled structures, is discussed. Their influence, both separately and in interaction, on the response of structures controlled by a modified pole placement algorithm is investigated. Characteristic buildings controlled by this algorithm and subjected to dynamic loads, such as harmonic signals and actual seismic events, are analyzed for a range of levels of time delay and saturation capacity of the control devices. The response reduction surfaces for the combined influence of time delay and force saturation of the controlled buildings are obtained. Conclusions regarding the choice of the control system and the desired properties of the control devices are drawn.

Speed Control of DC Motor Using Deadbeat Response Method (유한시간 정정응답에 의한 직류전동기의 속도제어)

  • 김영석;유완식
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1991.10a
    • /
    • pp.53-58
    • /
    • 1991
  • This paper presents the speed control of DC motor based on deadbeat response method. Since 송 deadbeat response systems are characterized by the discrete time control, the instabiliby of the systems caused by saturation and time lag problems is inevitable. In order to release these problems, we propose a compensator utilizing the predictive control so that the fast response can be also achieved in the saturation state. Experimental results demonstrated that outputs are able to settle final values in on sampling time for unsaturated reference inputs. For saturated reference inputs, outputs take one sampling time after getting free from the saturation state. Further we are able to settle the fast response with suppressed overshoot by appling the predictive control.

  • PDF

Development of the RE indirect-heating LPE furnace and the effect of impurity in YIG film on the MSSW properties

  • Fujino, M.;Fujii, T.;Sakabe, Y.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.12 no.6
    • /
    • pp.288-291
    • /
    • 2002
  • We developed a new RF indirect-heating LPE furnace. The thermal gradient of our newly developed furnace is less than that of direct heating, and is as gentle as that of the resistance-heating LPE furnace. With this new furnace, the heating and/or cooling is faster than that of the resistance-heating furnace. Impurity-doped YIG film was grown from a $PbO-B_{2}O_{3}$, based flux on a (111) GGG substrate. To study the effect of the impurities on the MSSW threshold power and the saturation response time, we used two microstrip lines to excite and propagate the MSSW at 1.9 GHz. The MSSW threshold power and saturation response time was found to be related to the $\Delta$H.

Transient Response Analysis of DC Voltage Regulating System with Amplidyne Saturation Effect (Amplidyne의 포화현상을 고려한 직류정전압계통의 과도응답 해석)

  • 이승원;김남호
    • 전기의세계
    • /
    • v.26 no.6
    • /
    • pp.55-58
    • /
    • 1977
  • This paper deals with the transient analysis of an amplidyne dc voltage regulating system under the following conditions: (1) assuming all the components of the system to be linear, (2) considering the effect of amplidyne saturation. The mathematical technique employed is state variables method. The calculated response curves are compared with the experimental results obtained on a practical system. The main results can be summerized as follows: 1) The effect of amplidyne saturation on the transient response of a dc voltage regulating system is to reduce the overshoot and setting time. 2) With the increase in level of the step reference voltage, the system response becomes apesiodic. 3) The steady output voltage is reduced appreciably compared to the linear case.

  • PDF

Synchronization of T-S Fuzzy Chaotic System with Time-Delay and Input Saturation (시간지연과 입력포화를 갖는 T-S 퍼지 카오스 시스템의 동기화)

  • Kim Jae-Hun;Shin Hyunseok;Kim Euntai;Park Mignon
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.42 no.1
    • /
    • pp.13-21
    • /
    • 2005
  • This paper presents a fuzzy model-based approach for synchronization of time-delay chaotic system with input saturation. Time-delay chaotic drive and response system is respectively represented by Takagi-Sugeno (T-S) fuzzy model. Specially, the response system contains input saturation. Using the unidirectional linear error feedback and the parallel distributed compensation (PDC) scheme, we design fuzzy chaotic synchronization system and analyze local stability for synchronization error dynamics. Since time-delay in the transmission channel always exists, we also take it into consideration. The sufficient condition for the local stability of the fuzzy synchronization system with input saturation and time-delay is derived by applying Lyapunov-Krasovskii theory and solving linear matrix inequalities (LMI's) problem. A numerical example is given to demonstrate the validity of the proposed approach.

Seismic response control of buildings with force saturation constraints

  • Ubertini, Filippo;Materazzi, A. Luigi
    • Smart Structures and Systems
    • /
    • v.12 no.2
    • /
    • pp.157-179
    • /
    • 2013
  • We present an approach, based on the state dependent Riccati equation, for designing non-collocated seismic response control strategies for buildings accounting for physical constraints, with particular attention to force saturation. We consider both cases of active control using general actuators and semi-active control using magnetorheological dampers. The formulation includes multi control devices, acceleration feedback and time delay compensation. In the active case, the proposed approach is a generalization of the classic linear quadratic regulator, while, in the semi-active case, it represents a novel generalization of the well-established modified clipped optimal approach. As discussed in the paper, the main advantage of the proposed approach with respect to existing strategies is that it allows to naturally handle a broad class of non-linearities as well as different types of control constraints, not limited to force saturation but also including, for instance, displacement limitations. Numerical results on a typical building benchmark problem demonstrate that these additional features are achieved with essentially the same control effectiveness of existing saturation control strategies.

Preparation and Nonlinear Optical Properties of CuCl-doped Nonlinear Optical Glasses : II. Nonlinear Optical Properties (CuCl 미립자가 분산된 비선형 광학유리의 제조와 비선형 광특성: II. 비선형 광특성)

  • 윤영권;한원택;이민영
    • Journal of the Korean Ceramic Society
    • /
    • v.34 no.4
    • /
    • pp.429-435
    • /
    • 1997
  • The third order nonlinear optical susceptibilities, {{{{ chi }}(3), of the CuCl doped alumino-borosilicate glasses were measured by the two beam configuration DFWM method and the absorption saturation method, and the measured {{{{ chi }}(3) values were about 10-8 esu in both methods. The response time was estimated to be about 105ps from the time decay curve of the luminescence spectra obtained by time-correlated single-photon counting (TCSPC) method.

  • PDF

Development of Gasoline Direct Swirl Injector II (직접분사식 가솔린 선회분사기 개발에 관한 연구 II)

  • 박용국;이충원
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.6
    • /
    • pp.76-84
    • /
    • 2001
  • Generally fuel injection system using solenoid have some problems between control signal and mechanical movement like as time lag. Main purpose of the present study is to help the design optimization of GDSI for real engine application. We have adopted two different solenoid driving circuit, namely saturation and pick-hold type and have investigated experimentally the current, needle force, needle opening duration and injection quantity. The pick-hold type driving circuit surpassed a saturation type in the response time and pression control of injection quantity. Accordingly, Using characterization data of operating factors such as time constant, driving force and so on, can be evaluated and adjusted to obtain an optimum injector performance.

  • PDF

Speed Control of D.C Motor based on Deadbeat Response (직류 전동기의 유한 시간 정정 응답 제어)

  • Kim, Young-Seok;You, Wan-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.371-374
    • /
    • 1990
  • This paper presents the speed control of dc motor based on deadbeat response. The deadbeat response is that the output reaches the final value in the minimum possible settling time and stays there. This results demonstrate that the output reaches final value in one sampling time for the unsaturated region, and in one sampling time after getting free from the saturation state for the saturated region.

  • PDF

A Study on Change of Soil-Water Retention Curve with Different Net Confining Pressures and Porosities using a Suction-Saturation Control Technique (흡입력-포화도 조절 기법을 이용한 불포화토의 함수특성곡선에 미치는 간극비 및 순구속압력의 영향 연구)

  • Lee, Joon-Yong;Yu, Chan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.4
    • /
    • pp.93-103
    • /
    • 2012
  • A suction-saturation control technique based on flow pump system was developed to investigate hydraulic properties in unsaturated soils. The flow pump system is designed based on the principle of the axis-translation technique and triaxial equipment, and gives the suction-time and suction-saturation curves, the primary relationship needed for interpreting the response of unsaturated soils and link between theory and the material properties in unsaturated soil mechanics. Using the suction-saturation control technique, suction-time relationship and soil-water retention curve (SWRC) during hydraulic hysteresis were investigated with different net confining pressures and porosities. Three types of soils-two sands and a silt were used in this paper. This paper showed the effect of the hysteresis on the SWRC due to different net confining pressures and porosities. This means that a careful decision must be made as to which condition is to be modeled, since the delicate difference of the conditions in physical modeling can cause the different experimental output.