• Title/Summary/Keyword: Saturation flow rate

Search Result 126, Processing Time 0.024 seconds

Ideal Saturation Flow Rate and Geometric Adjustment Factors at Urban Signalized Intersection (도시부 신호교차로의 기본용량 및 기하구조 보정계수)

  • 오영태;심대영
    • Journal of Korean Society of Transportation
    • /
    • v.10 no.2
    • /
    • pp.5-24
    • /
    • 1992
  • This research presets the method of determining basic capacity of signalized intersection using the concept of ideal saturation flow rate. Vehicle discharge rates during green time were collected and studied as part of the preparation of Korean Highway Capacity Manual. From the result of this study the ideal saturation flow rate and saturation queue position were determined. In addition, based on the ideal saturation flow rate two geometric adjustment factors(lane width and grade adjustment factors) were studied. The results were presented in this paper.

  • PDF

Analysis of Saturation Flow Rate on Interrupted Flow During Rainfall (강우시 단속류 포화교통류율 변화 분석)

  • Kim, Bongseok;Roh, Chang-Gyun;Son, Bongsoo
    • Journal of Korean Society of Transportation
    • /
    • v.33 no.1
    • /
    • pp.90-99
    • /
    • 2015
  • The climate of Korea has clear rainy and dry season due to seasonal wind. In general, The rainy season in Korea is from early summer through to early fall. And precipitation accounted for more than half of the total annual rainfall in this period. This study is aiming to analysis of variation in saturation flow rate at signalized intersection during rainfall. The range of spatial is urban signalized intersections in Seoul and temporal is rainfall or ideal condition in daylight. Traffic data are collected through CCTV of Seoul Metropolitan Police Agency, and on-site video recordings directly. Weather condition data are collected from the Korea Meteorological Administration. In addition, the value of saturation headway and saturation flow rate, in rainfall condition, are derived through video frame analysis. As a results of analysis, decrease of saturation flow rate and increase of saturation headway during rainfall were confirmed by comparison with non-rainfall. The higher rainfall rate is, the more decreased saturation flow rate at the intersections. Rainfall rate is divided three area by the results of statistical test, and saturation flow rate decrease 7%, 17%, 21%, respectively.

Development of Saturation Flow Rate Estimation Models Considering Workzone in the Vicinity of Signalized Intersections (도시부 신호교차로 인근 도로점용공사를 고려한 포화교통류율 산정모형 개발에 관한 연구)

  • Eo, Hyo-Gyeong;Sin, Chi-Hyeon
    • Journal of Korean Society of Transportation
    • /
    • v.28 no.6
    • /
    • pp.109-120
    • /
    • 2010
  • This study aims to develop mathematical models for estimating saturation flow rates at the stop line of signalized intersection due to Workzones in the vicinity, since the saturation flow rate is the most critical parameter in capacity analysis for signalized intersections. It was found by reference review that saturation flow rates are sensitively influenced by the location of Workzone, the number of lanes, cycle length and effective green time. Extensive microscopic simulation runs were also performed and compared to the those of mathematical models for model verification. Mathematical models were developed based on traffic flow theory and dualizing them by the location of workzones. And then each result produced by changing important parameter values was carefully examined and analyzed. Small but consistent differences in saturation flow rate values between mathematical models and simulations exist. However, the pattern of changes in saturation flow rates depending on each variable was similar.

Penetration behavior of biopolymer aqueous solutions considering rheological properties

  • Ryou, Jae-Eun;Jung, Jongwon
    • Geomechanics and Engineering
    • /
    • v.29 no.3
    • /
    • pp.259-267
    • /
    • 2022
  • The rheological and penetration characteristics of sodium alginate and xanthan gum aqueous solutions were analyzed for the development of biopolymer-based injection materials. The results of viscosity measurements for the rheological characteristics analysis show that all aqueous biopolymer solutions exhibit a tendency for shear-thinning, i.e., the apparent viscosity decreases as the shear rate increases. In addition, a regression analysis using several models (Power-law, Casson, Sisko, and Cross) was applied to the shear-thinning fluid analysis results, the highest accuracy was determined by applying the power-law model. The micromodel experiment for the penetration characteristics analysis determined that all biopolymer aqueous solutions show higher pore saturation than water, and that pore saturation tends to increase as the flow rate and concentration increases. When comparing the rheological and penetration characteristics of the biopolymer aqueous solution used in this study, the xanthan gum aqueous solution showed a fully developed shear-thinning tendency, unlike the sodium alginate aqueous solution. This tendency is considered to have the advantage of enhancement injectability and pore saturation.

Capacity and Saturation Flow Rate of Permissive Left-Turn Lane: in case for the Exclusive Use of Permissive Left-Turn Movements (비보호(非保護) 좌회전(左回轉)의 간격수락(間隔受諾)과 용량(容量) 및 보정계수(補整係數)에 관한 연구)

  • Do, Cheol Ung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.6
    • /
    • pp.1273-1279
    • /
    • 1994
  • There are 3 cases that only permissive left-turn(PLT) vehicles use the possible lane for PLT. In these cases, left turn and through movements can not be included in the same lane group, hence saturation flow rate and left turn adjustment factor of PLT are obtained separately from through movement. In capacity analysis procedures at signalized intersection with PLT phasing, PLT capacity should be known to discriminate among 3 cases stated above. The capacity is directly used not only to get saturation flow rate and left turn adjustment factor, but as a threshold for the feasibility of PLT control. This study calculated through field data the critical gap and minimum headway of left turn which affect the PLT capacity. The capacity was obtained by using theoretical models, which consequently could be used to calculate the saturation flow rate and left turn adjustment factor.

  • PDF

Analysis of spray cone angle of air assisted flash atomization (공기보조식 (air-assisted) 플래쉬 분무의 분무 각 확대 특성 연구)

  • Yu, Tae-U;Kim, Sae-Won;Bang, Byong-Ryeol
    • Journal of ILASS-Korea
    • /
    • v.10 no.1
    • /
    • pp.1-9
    • /
    • 2005
  • When the water jets heated up to the saturation temperature at a high line pressure are sprayed into a reduced (atmospheric) pressure through an air-assisted nozzle, the jets experience sudden exposure into a reduced pressure, get superheated and produce steam bubbles while atomization processes of jets are taking place. This process is called flash atomization. In this study the flash atomization of superheated water jets assisted by air has been studied. Sprays with flash atomization have been photographed at various water and air flow rates and water superheats. It has been found that the spray angle with flash atomization increases with water superheat and water flow rate but decreases with air flow rate. The degree of change of spray angle has been analyzed and correlated as a function of superheat, air and water flow rates.

  • PDF

Estimation of Bus Saturation Flow Rates at Signalized Intersections Including Exclusive Median Bus Lanes (중앙버스전용차로가 설치된 신호교차로에서의 버스 포화교통류율 산정에 관한 연구)

  • Cho, Hanseon;Lee, Jae-Joon
    • Journal of Korean Society of Transportation
    • /
    • v.31 no.3
    • /
    • pp.65-73
    • /
    • 2013
  • Exclusive median bus lanes were installed to mitigate congestions on urban traffic networks. However, capacity analysis of signalized intersections having exclusive median bus lanes have not been provided in current capacity analysis process(analyses). This study aims to develop a method of capacity analysis for lane groups consisting of only buses at the signalized intersections having exclusive median bus lanes. Finding basic saturation flow rates for buses is critical since the operational characteristics between automobiles and buses are fairly different. A total of 8 intersections in Seoul were chosen as study sites. Saturation headways, distances between bus-stop and stopline, and grades of each approach were measured at the sites. It was found that the basic saturation headway and the basic saturation flow rate of buses were 3.27 s/veh and 1,100pc/h/ln, respectively. Adjustment factor for upstream bus-stop locations was estimated with 0.50 and 0.75 when the distances between bus-stop and stopline are 20m and 70m, respectively. This study explains that bus saturation flow rates are decreased in half if the bus stop locates within 20 meters from stop lines.

Comparative Study of Fluidized Bed-type and Assmann Psychrometer (유동층습도계와 아스만습도계의 비교 연구)

  • 강희찬;강민철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.9
    • /
    • pp.779-785
    • /
    • 2003
  • The present work proposed a newly developed fluidized bed-type psychrometer that could be applicable to the high temperature and contaminant gases. The psychrometer is a device that test gas passes through the water in a glass bottle as a bubbly flow to obtain the adiabatic saturation temperature. A fluidized bed-type psychrometer was made and its characteristics were compared with the Assmann Psychrometer. The characteristic time was in the order of a hundred seconds, and decreased for the decrease of the mass of water and the increase of the air flow rate. The air flow rate and the insulation of the glass bottle were definitely important in the accurate measurement of the wet bulb temperature. The error in wet bulb temperature became less than 5 percent of the difference of dry and wet bulb temperatures if the air velocity in the glass bottle was greater than 1.5m/s.

A Basic Investigation on the Characteristics of Traffic Flow for the Capacity Analysis of Signalized Intersections (교차로 용량분석을 위한 교통류 특성 기초조사)

  • 이승환
    • Journal of Korean Society of Transportation
    • /
    • v.7 no.2
    • /
    • pp.89-111
    • /
    • 1989
  • This study concentrates on a basic investigation research related to some of parameters to be used for the analysis of capacity and the level of service for signalized intersections. The parameters to be studied are ideal saturation flow rate, large vehicle's passenger car equivalent(PCE) ane the lane utilization factors of through and left turn vehicles. The field data were collected at six intersections in Seoul using video cameras so as to reflect conditions in urban areas. In this study discharge headway based on a rear bumper of each vehicle was used and all the parameters were estimated using a regression technique. The findings of this research are as follows : 1. The saturation headway and saturation flow rate on a single lane with the lane width of 3.1m are 1.652 seconds and 2,180 pcphgpl. It was found that the frist 5 vehicles in the queue experience some start-up lost time. 2. It was confirmed that the new method adopted for the estimate of large vehicle's PCE gives larger PCE values than those derived from the method commonly used. 3. For the estimate of lane utilization factors of through and left turn vehicles, a relationship was established and the corresponding formulas were developed.

  • PDF

Optimization of the $POCI_3$ doping process according to the variation of deposition temperature, gas flow rate and doping time (온도, 가스량 및 도핑시간변화에 따른 $POCI_3$ 도핑 공정의 최적화)

  • 정경화;강정진
    • Electrical & Electronic Materials
    • /
    • v.7 no.3
    • /
    • pp.206-212
    • /
    • 1994
  • In this paper, We discuss the $POCI_3$ doping process according to the variation of deposition temperature, gas flow rate and doping time. The factors acted with $POCI_3$ doping are gas flow rate deposition temperature and time etc. Among them the temperature is the most important factor. For the $POCI_3$ flow rate, it should not exceed the resistivity saturation point developed on poly surface by annealing treatment. Therefore, this study suggests the optimum conditions of Poly-silicon treatments with the $POCI_3$ flow rate.

  • PDF