• 제목/요약/키워드: Saturation Temperature

검색결과 936건 처리시간 0.027초

무전극형광램프의 고온 신뢰성 연구 (High Temperature Reliability Study of Low Frequency In-door Electrodeless Lamp)

  • 정의효;형재필;임성용;임홍우;장중순
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제14권3호
    • /
    • pp.203-207
    • /
    • 2014
  • Electrodeless lamp is famous for its long life. But its reliability is dependent not only on electrodes but also on materials and structures. To evaluate end product's reliability, we studied high temperature durability by $60^{\circ}C$, $75^{\circ}C$ and $90^{\circ}C$ temperature tests, and predicted failure times by an exponential model through regression analysis. However, the test showed that temperature does not affect degradation of electrodeless lamps. Their luminous outputs degrade during the early time of the test (till 250 hours) and then converge to a saturation points. Also, '410nm ~ 530nm' spectrum degrades more than other spectra.

An approach to model the temperature effects on I-V characteristics of CNTFETs

  • Marani, Roberto;Perri, Anna G.
    • Advances in nano research
    • /
    • 제5권1호
    • /
    • pp.61-67
    • /
    • 2017
  • A semi-empirical approach to model the temperature effects on I-V characteristics of Carbon Nanotube Field Effect Transistors (CNTFETs) is proposed. The model includes two thermal parameters describing CNTFET behaviour in terms of saturation drain current and threshold voltage, whose values are extracted from the simulated and trans-characteristics of the device in different temperature conditions. Our results are compared with those of a numerical model online available, obtaining I-V characteristics comparable but with a lower CPU calculation time.

The Characteristics of a Pump at Nearly Saturated State

  • Kim, S. N.;Kim, J. C.
    • Nuclear Engineering and Technology
    • /
    • 제30권1호
    • /
    • pp.40-46
    • /
    • 1998
  • A set of experiments using a 1/10 scale model pump which was manufactured to simulate performance of reactor coolant pump(RCP) of Y.G.N # 3 and 4, was executed in single phase(at atmospheric pressure and room temperature) and near-saturation(300 ~ 600kPa). The pump characteristics in single phase flow was similar to the characteristics of the RCP. The pump characteristic curves at nearly saturated state were correlated in terms of flow coefficient and head coefficient for subcooled temperature using the cavitation number defined as (equation omitted), which can be predicted the cavitation possibility. The pump behavior around the saturated temperature almost consists with single phase behavior until the cavitation occurs(When cavitation occurs. When the flow coefficient is about 0.12), the pump head rapidly degrades. In this situation, subcooled temperature is about 1.8~8$^{\circ}C$ and cavitation number of model pump is 1.0 ~ 1.7.

  • PDF

Low temperature curable organic gate insulator for organic field-effect transistors

  • Kim, Joo-Young;Jung, Myung-Sup;Lee, Sang-Yoon;Kim, Jong-Min;Kim, Jang-Joo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.664-666
    • /
    • 2008
  • Low-temperature curable organic insulator was prepared through blending of polyimide type base resin and cross-linking agent. The newly developed resin can be formed into films using a wet process and cured at $130^{\circ}C$. Using the low temperature cured film as the gate dielectric layer, the field effect mobility of $0.15\;cm^2/V{\cdot}s$ was obtained from a pentacene field effect transistor in the saturation regime and no hysteresis behavior was observed in transfer curves.

  • PDF

개별공조시스템을 위한 전기히터의 PID 제어 (A PID Control of Electric Heater for PEM)

  • 장영준;박영칠;정광섭;한화택;이정재
    • 설비공학논문집
    • /
    • 제13권1호
    • /
    • pp.59-65
    • /
    • 2001
  • The work presented here is an implementation of PID control to achieve a required supply air temperature in PEM(Personal environment module). In PEM, the air is heated to the required temperature while it flows through the supply duct, without any mixing chamber. This makes the control of air temperature in PEM difficult. Linear dynamic model of heat transfer in PEM is first obtained. Then P, PD and PID type control systems, to provide the rapid response without overshoot and saturation, are designed and implemented experimentally. Data obtained shows that the control system satisfied the design criteria and works properly in controlling the supply air temperature.

  • PDF

과냉 비등류의 실제건도와 보이드율에 관한 연구 (A Study on the Real Quality and Void Fraction of Subcooled Refrigerant Flow)

  • 김종헌;김춘식;김경근;오철
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제17권2호
    • /
    • pp.36-43
    • /
    • 1993
  • Real quality and axial void fraction distribution of subcooled refrigerant flow is very important to predict the heat transfer rate and pressure drop in the design of refrigerating system. In the subcooled boiling region, the liquid bulk temperature is still below the corresponding saturation temperature. But beyond the net vapor generation point, bubble detachment is occured actively from the vapor layer formed on the wall. A reliable method to predict the vapor fraction from the liquid bulk temperature is suggested in this paper. And also the actual quality of the subcooled R-113 flow is calculated in the range of 261-1239kg/$m^2$s mass velocity and 10-30K subcooling.

  • PDF

CaAs 해양전지의 온도특성 (The Operating Temperature Effects on GaAs Solar Cells)

  • 이승기;한민구;정기옹;권영세
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 정기총회 및 창립40주년기념 학술대회 학회본부
    • /
    • pp.203-206
    • /
    • 1987
  • $Ga_{1-x}Al_xAs$ solar cells have been fabricated by LPE and characterized as a function of operating temperature from $25^{\circ}C$ to $l30^{\circ}C$. Open circuit voltage decreases linearly with increasing temperature by $1.4mv/^{\circ}C$, while degradation of silicon solar cells is about $2.2-2.5\;mv/^{\circ}C$. Experimental results regarding to GaAS solar cells, such as saturation current, ideality factors and fill factors are characterized as a function of operating temperature.

  • PDF

Pd 첨가와 기판온도 변화에 따른 퍼말로이 합금박막의 자기특성변화 (Influence of Pd Concentration and Substrate Temperatures on the Magnetic Property in Permalloy Films)

  • 이기영;송오성;윤종승;김경각
    • 한국전기전자재료학회논문지
    • /
    • 제15권9호
    • /
    • pp.818-821
    • /
    • 2002
  • We investigated the evolution of magnetic property with varying palladium (Pd) contents and elevating substrate temperatures up to 200 $^{\circ}C$ during dc-sputtering. We observed that saturation magnetization (Ms), remanence and anisotropic magnetoresistance (AMR) ratio decrease with Pd contents in the case of keeping the substrate temperature at 3$0^{\circ}C$. However they increase by adding 2 %Pd, then decrease above 3 %Pd when we keep the substrate temperature at 20$0^{\circ}C$. Coercivity does not change with Pd contents. Our results imply that we may tune the Ms and AMR with Pd contents and substrate temperature in permalloy films.

Low Temperature Magnetization and Spin Wave Excitations in Amorphous Fe67 Co18B14Si1

  • Yoo, Yong-Goo;Yu, Seong-Cho;Hans A. Graf
    • Journal of Magnetics
    • /
    • 제2권3호
    • /
    • pp.72-75
    • /
    • 1997
  • The temperature dependent saturation magnetization curve of amorphous Fe67 Co18B14Si1, alloy was measured using a SQUID magnetometer and vibrating sample magnetometer from 5 K up to 800 K. Inelastic neutron neutron scattering measurements also have been used to study the long wavelength spin dynamics of this high Tc amorphous ferromagnetic alloy. The magnon dispersion curve exhibit the conventional quadratic relationship E = D (T) q2 + $\Delta$, typical of an iso=obtained from a low temperature magnetization curve, which was consistent with the value obtained from the analysis oif inelastic neutron scattering data after consideration of its temperature dependence.

  • PDF

A Numerical Study on Cavitation Suppression Using Local Cooling

  • Zhang, Yuan-Yuan;Sun, Xiao-Jing;Huang, Dian-Gui
    • International Journal of Fluid Machinery and Systems
    • /
    • 제3권4호
    • /
    • pp.292-300
    • /
    • 2010
  • This study strives to develop an effective strategy to inhibit cavitation inception on hydrofoils by using local cooling technique. By setting up a temperature boundary condition and cooling a small area on the upper surface of a hydrofoil, the fluid temperature around the cooling surface will be decreased and thereby the corresponding liquid saturation pressure will drop below the lowest absolute pressure within the flow field. Hence, cavitation can never occur. In this paper, a NACA0015 hydrofoil at $4^{\circ}$ angle of attack was numerically investigated to verify the effectiveness of the proposed technique. The CFD results indicate that the cooling temperature and the cooling surface roughness are the critical factors affecting the success of such technique used for cavitation suppression.