• Title/Summary/Keyword: Saturated vapor density

Search Result 15, Processing Time 0.035 seconds

A new type of saturated vapor density correlation for refrigerants (냉매에 대한 새로운 유형의 포화증기밀도 상관식)

  • 박경근
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.5
    • /
    • pp.550-557
    • /
    • 1998
  • The saturated vapor density correlation proposed here relates logarithmic density to the inverse of temperature. Its performance is examined correlating the date listed in the ASHTAE tables for 40 refrigerants. The correlation equation is valid over the entire range where data point exist and gives better results than a conventional equation with the same number of adjustable coefficients. Number of terms in the equation is a variable so that great flexibility can be given to the representation of data.

  • PDF

Comparison of Correlations of Saturated Vapor Density for Some Refrigerants (냉매의 포화증기밀도 상관식 비교)

  • Park, Kyoung-Kuhn;Kang, Byung-Ha;Jang, Si-Youl
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.6
    • /
    • pp.457-463
    • /
    • 2007
  • Various correlations of saturated vapor density in a truncated power series form are tested and compared in this study. Saturated vapor density correlation can be expressed relating logarithmic reduced density to the reduced temperature. Five types of correlation has been investigated using saturated vapor density data for 22 pure substance refrigerants from ASHRAE (American Society of Heating, Reftigerating and Air-Conditioning Engineers, Inc.) property tables and NIST (National Institute of Standards and Technology) Chemistry Webbook. Correlations are fitted to the data points by least squares method. Data points are equally weighted. The best type of correlation among the five types is suggested. The results obtained indicate that the best correlations with 3, 4, and 5 terms yield average AAD's (Average Absolute Deviation) of 0.27%, 0.04%, and 0.02%, respectively, while widely used conventional correlations with 3, 4, and 5 terms yield those of 1.19%, 0.61%, and 0.17%. The suggested type of correlation could reduce the number of terms while improving performance.

Calculation of the Thermodynamic Properties of R-134a and A Preliminary Study of the Refrigeration Performance (R-134a의 열역학적 물성치 계산과 냉동 성능에 관한 연구)

  • Park, Y.M.;Lee, H.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.4
    • /
    • pp.286-296
    • /
    • 1991
  • The thermodynamic properties of R134a, the prospective R12 alternative, have been computerized using Martin-Hou equation of state and the coefficients given by Willson-Basu. Several experimental results in literatures for PVT data, saturated vapor pressure, saturated liquid density are compared with the calculated results to investigate the accuracy. The average deviation (max. deviation) is 0.13% (0.25%) for saturated liquid density, 0.25% (0.8%) for PVT data. Thermodynamic properties, enthalpy, entropy are compared with the NIST's. The maximum percent difference is 3% for saturated liquid enthalpy, 1.5% for saturated vapor enthalpy, 4% saturated liquid entropy, and 0.7% for saturated vapor entropy. Correction of W-B's coefficients and inclusion of the sixth term of M-H EOS for improvement of accuracy are recommended. R134a and R12 are compared with respect to refrigeration performance. COP's are different from each other within 3%. Refrigeration effect of R134a is superior to that of R12 but refrigeration capacity of R134a is inferior to that of R12 because the volumetric efficiency of the system using R134a is lower than that of the system using R12.

  • PDF

Measurements of Droplet Sizes and Velocities with Optimum Probability Density Function in a Transient Liquefied Butane Spray (액상부탄 간헐분무의 액적 크기 및 속도 측정과 최적 확률분포 연구)

  • Kim, J.H.;Kim, J.W.;Koo, J.Y.
    • Journal of ILASS-Korea
    • /
    • v.5 no.1
    • /
    • pp.30-40
    • /
    • 2000
  • The characteristics of liquefied butane spray are expected to be different from conventional diesel fuel spray, because a kind of flash boiling spray is expected when the back pressure is below the saturated vapor pressure of the butane(0.23MPa at 298K). The ambient pressure was held at a pressure above(0.37MPa) and below(0.15MPa) the fuel vapor pressure. The axial velocities, radial velocities, and size distributions in butane sprays were measured with PDPA(Phase Doppler Particle Analyzer) system. The PDPA measurement showed a smaller SMD at the 0.15MPa chamber pressure, compared to the 0.37MPa case. Log-hyperbolic density function for the droplets size distribution can be fitted to the experimental results of a liquefied butane spray.

  • PDF

Effeet of Al2O3, MgO and SiO2 on Sintering and Hydration Behaviors of CaO Ceramics

  • Kim, Do-Kyung;Cho, Churl-Hee;Goo, Bong-Jin;Lee, Kee-Sung
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.6
    • /
    • pp.528-534
    • /
    • 2002
  • CaO ceramics were prepared by conventional sintering process and their hydration behaviors were evaluated by measuring weight increment on saturated water vapor pressure at ambient temperature. CaCO$_3$ and limestone were used as CaO source materials and $Al_2$O$_3$, MgO and SiO$_2$ were added as sintering agents. $Al_2$O$_3$ was a liquid phase sintering agent to increase densification and grain growth rates, whereas MgO and SiO$_2$, densification and grain growth inhibitors. Regardless of composition, all of the prepared CaO ceramics showed the improved hydration resistance as bulk density increased. Especially, when bulk density was more than 3.0 g/㎤, there was no weight increment after 120 h of hydration. Therefore, to decrease contact area between CaO and water vapor by increasing bulk density with the $Al_2$O$_3$ sintering additive was effective for the improvement of CaO hydration resistance.

Metal-Organic Chemical Vapor Deposition of $Pb(Zr_xTi_{1-x})O_3$ Thin Films for High-Density Ferroelectric Random Access Memory Application

  • Lee, June-Key;Ku, June-Mo;Cho, Chung-Rae;Lee, Yong-Kyun;Sangmin Shin;Park, Youngsoo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.2 no.3
    • /
    • pp.205-212
    • /
    • 2002
  • The growth characteristics of metal-organic chemical vapor deposition (MOCVD) $Pb(Zr_xTi_{1-x})O_3 (PZT) thin films were investigated for the application of high-density ferroelectric random access memories (FRAM) devices beyond 64Mbit density. The supply control of Pb precursor plays the most critical role in order to achieve a reliable process for PZT thin film deposition. We have monitored the changes in the microstructure and electrical properties of films on increasing the Pb precursor supply into the reaction chamber. Under optimized conditions, $Ir/IrO_2/PZT(100nm)/Ir capacitor shows well-saturated hysteresis loops with a remanent polarization (Pr) of $~28{\mu}C/textrm{cm}^2$ and coercive voltage of 0.8V at 2.5V. Other issues such as step coverage, compositional uniformity and low temperature deposition was discussed in viewpoint of actual device application.

Synthesis of Au Nanowires Using S-L-S Mechanism (S-L-S 성장기구를 이용한 양질의 골드 나노선 합성)

  • No, Im-Jun;Kim, Sung-Hyun;Shin, Paik-Kyun;Cho, Jin-Woo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.11
    • /
    • pp.922-925
    • /
    • 2012
  • Single crystalline Au nanowires were successfully synthesized in a tube-type furnace. The Au nanowires were grown by vapor phase synthesis technique using solid-liquid-solid (SLS) mechanism on substrates of corning glass and Si wafer. Prior to Au nanowire synthesis, Au thin film served as both catalyst and source for Au nanowire was prepared by sputtering process. Average length of the grown Au nanowires was approximately 1 ${\mu}m$ on both the corning glass and Si wafer substrates, while the diameter and the density of which were dependent on the thickness of the Au thin film. To induce a super-saturated states for the Au particle catalyst and Au molecules during the Au nanowire synthesis, thickness of the Au catalyst thin film was fixed to 10 nm or 20 nm. Additionally, synthesis of the Au nanowires was carried out without introducing carrier gas in the tube furnace, and synthesis temperature was varied to investigate the temperature effect on the resulting Au nanowire characteristics.

An Analysis of Water Vapor Pressure to Simulate the Relative Humidity in Rural and Mountainous Regions (고해상도 상대습도 모의를 위한 농산촌 지역의 수증기압 분석)

  • Kim, Soo-ock;Hwang, Kyu-Hong;Hong, Ki-Young;Seo, Hee-Chul;Bang, Ha-Neul
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.22 no.4
    • /
    • pp.299-311
    • /
    • 2020
  • This paper analyzes the distribution of water vapor pressure and relative humidity in complex terrains by collecting weather observation data at 6 locations in the valley in Jungdae-ri, Ganjeon-myeon, Gurye-gun, Jeolla South Province and 14 locations in Akyang-myeon, Hadong-gun, Gyeongsang South Province, which form a single drainage basin in rural and mountainous regions. Previously estimated water vapor pressure used in the early warning system for agrometeorological hazard and actual water vapor pressure arrived at using the temperature and humidity that were measured at the highest density (1.5 m above ground) at every hour in the valley of Jungdae-ri between 19 December 2014 and 23 November 2015 and in the valley of Akyang between 15 August 2012 and 18 August 2013 were compared. The altitude-specific gradient of the observed water vapor pressure varied with different hours of the day and the difference in water vapor pressure between high and low altitudes increased in the night. The hourly variations in the water vapor pressure in the weather stations of the valley of Akyang with various topographic and ground conditions were caused by factors other than altitude. From the observed data of the study area, a coefficient that adj usts the variation in the water vapor pressure according to the specific difference in altitude and estimates it closer to the actual measured level was derived. Relative humidity was simulated as water vapor pressure estimated against the saturated water vapor pressure, thus, confirming that errors were further reduced using the derived coefficient than with the previous method that was used in the early warning system.

Performance Evaluation of Wall Blower Nozzle using Erosion Analysis (침식 해석을 이용한 월 블로워 노즐의 성능 예측)

  • Paek, Jae Ho;Jang, llkwang;Jang, Yong Hoon
    • Tribology and Lubricants
    • /
    • v.34 no.5
    • /
    • pp.175-182
    • /
    • 2018
  • Accumulation of coal ash at the boiler wall reduces combustion and fuel efficiency. The design of a wall blower is important to effectively remove coal ash. We present numerical results for the removal of coal ash from boiler walls of domestic coal-fired power plants, associated with the computational fluid dynamics for the flow from spray nozzle to boiler wall. The numerical model simulates an erosion process in which the multiphase fluid comprising saturated vapor and fluid water is sprayed from the nozzle, and the water particles impact the boiler wall. We adopt the Finnie erosion model for water particles. We obtain the erosion rate density as a function of nozzle angle and its injection angle. As excessive coal ash removal usually induces damage to the boiler wall, the removal operation typically focuses on a large area with uniform depth rather than the maximum removal of coal ash at a specific location. In order to estimate the removal performance of the wall blower nozzle considering several functionality and reliability factors, we evaluate the optimal injection and nozzle angles with respect to the biggest cumulative and highest erosion rates, as well as the widest range and lowest standard deviation of the erosion rate distribution.

Effects of Light, Temperature, Water Changes on Physiological Responses of Kalopanax pictus Leaves(II) - Characteristics of Stomatal Transpiration, Water Efficiency, Vapor Pressure Deficit of Leaves by the Light Intensity - (광, 온도, 수분 변화에 따른 음나무 엽의 생리반응(II) - 광도변화에 따른 기공증산, 수분이용효율, 수증기압결핍 -)

  • Han, Sang-Sup;Jeon, Doo-Sik;Sim, Joo-Suk
    • Journal of Forest and Environmental Science
    • /
    • v.21 no.1
    • /
    • pp.92-97
    • /
    • 2005
  • This research was carried out to elucidate the characteristics of stomatal transpiration, water efficiency, vapor pressure deficit of leaves by the light intensity Kalopanax pictus leaves. The results obtained are summarized as follows: 1. In the upper leaves of Kalopanax pictus seedlings, the stomatal transpiration rate increased continuously with increasing light intensity, but in the middle and lower leaves. it was saturated at $100{\mu}mol\;m^{-2}S^{-1}$. At the light saturated point. the stomatal transpiration rate was in the following order: the upper ($1.29mmol\;H_2O\;m^{-2}S^{-1}$) middle ($0.56mmol\;H_2O\;m^{-2}S^{-1}$) lower leaves ($0.31mmol\;H_2O\;m^{-2}S^{-1}$). 2. In the upper leaves, water use efficiency rapidly increased to $600{\mu}mol\;m^{-2}S^{-1}$, and then decreased. In the middle and lower leaves, it increased to $400{\mu}mmol\;m^{-2}S^{-1}$, and then showed a constant values. 3. The vapor pressure deficit (VPD) in according to leaf positions was linearly decreased with increasing photosynthetic photon flux density (PPFD).

  • PDF