• 제목/요약/키워드: Saturated Surface Dry

검색결과 41건 처리시간 0.025초

함수비를 고려한 모래의 상대밀도 추정을 위한 Fall Cone 관입량의 적용 (Application of Penetration in Fall Cone Test to Estimate Relative Density with Variation of Water Content for Sand)

  • 최우석;손영환;박재성;노수각;봉태호
    • 한국농공학회논문집
    • /
    • 제54권5호
    • /
    • pp.69-77
    • /
    • 2012
  • Relative density, used to express dynamics condition of sand quantitatively, is measured by RI Test, Standard Penetration Test and Cone Penetration Test. Each measurement method has demerits, which is complicated or needs a specific analysis instrument and an analysis of expert. Also the ground is in wet condition commonly because of an unsaturated zone between a saturated zone and a surface, so the behaviour of the ground has different engineering properties unlike the dry ground and it diminishes accuracy of measuring relative density. In this study, the correlation between relative density and penetration of fall cone test in dry condition and wet condition with variation of water content was analyzed and a simple measuring method for relative density was suggested. As a result, there were difference of penetration between dry sands and wet sands, the correlation between relative density and penetration showed linear expression and relative density could be measured by the linear relation.

Theoretical Approach to Calculate Surface Chloride Content $C_s$ of Submerged Concrete under Sea Water Laden Environment

  • 윤인석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.197-200
    • /
    • 2006
  • The ingress of chloride ions plays a crucial role for service life design of reinforced concrete structures. In view of durability design of concrete structures under marine environment, one of the most essential parameters is the surface chloride content of concrete. However, on the basis of the results of in-situ investigation, this value has been determining in the numerous studies on the durability design of concrete structures. Hence, it is necessary to confirm the range of the surface chloride content in order to establish a unified durability design system of concrete. This study suggests a rational and practical way to calculate the maximum surface chloride content of submerged concrete under marine environment. This approach starts with the calculation of the amount of chloride ingredients in normal sea water. The capillary pore structure is modeled by numerical simulation model HYMOSTRUC and it is assumed to be completely saturated by the salt ingredients of sea water. In order to validate this approach, the total chloride content of the mortar and concrete slim disc specimen was measured after the immersion into the artificial sea water solution. Additionally, the theoretical, the experimental and in-situ investigation results of other researchers are compiled and analyzed. Based on this approach, it will follow to calculate the maximum surface chloride content of concrete at tidal zone, where the environment can be considered as a condition of dry-wetting cycles.

  • PDF

식품보장과 수분활성에 관한 연구 1. 조절기류에 의한 건조말쥐치육의 등온흡습곡선의 측정 (Studies on Food Preservation by Controlling Water Activity 1. Measurement of Sorption Isotherm of Dried Filefish Muscle by Equilibration in Dynamic Stream of Conditioned Air)

  • 한봉호;최수일
    • 한국수산과학회지
    • /
    • 제14권4호
    • /
    • pp.189-193
    • /
    • 1981
  • 등온흡습곡선측정시의 건제품이 주어진 대상습도에서 평형에 이르는 시간을 단축시키기 위하여 조절기류를 이용하는 장치를 만들고, 이를 이용하여 $25^{\circ}C$에서 말쥐치 건제품의 등온흡습곡선을 측정하였다. 1. 조절기류를 이용함으로써 주어진 수분활성에서보다 높은 수분활성에 이르는 시간을 평균 45 시간으로 단축시킬 수 있었다. 2. 단분자의 수분함양은 고형물 1kg당 0.092kg이었으며, 건조말쥐치의 제품에 대하여 $8.42\%$였다. Symbols used in the text A : surface, $m^2$ $a_w$: water activity $A_s$ : specific surface, $m^2/kg$ dry matter C : constant related to the heat of adsorption $K_g$ : gas film coefficient of mass transfer, $kg water/hr{\cdot}Pa{\cdot}m^2$ n : number of molecular layers $n_s$ : moisture content, kg water /kg dry matter $n_{sa}$ : mean moisture content, kg water/kg dry matter $n_{se}$ : equilibrium moisture content, kg water/kg dry matter $n_{sm}$ : moisture content for monolayer, kg water/kg dry matter $P_g$ : saturated vapor pressure at wet-bulb temperature, Pa $P_a$ : partial vapor pressure of water in air, Pa $R_d$ : resistance factor against diffusion, $m^2{\cdot}hr/kg$ dry matter $R_s$ : resistance factor against drying, $m^2{\cdot}hr/kg$ dry matter R.H. : relative humidity, $\%$ $\varphi$ : R.H./100

  • PDF

소루쟁이뿌리를 이용한 면직물 천연염색 (Natural Dyeing of Cotton Fabrics with Rumex crispus L. Root)

  • 한미란;이정숙
    • 한국의류학회지
    • /
    • 제33권2호
    • /
    • pp.222-229
    • /
    • 2009
  • The natural dyeing of cotton fabrics with Rumex crispus L. root extract was investigated. The dyeability of Rumex crispus L. root extract was evaluated with conditions of concentration, temperature, time, repeat-numbers, pH, mordants variables, methods of mordanting, color fastness and antibacterial activity, etc. The maximum V-visible spectrum possessed absorption band of Rumex crispus L. extract appeared at 274nm and 336nm. The amount of dyes extracted was increased with extracting concentration, temperature and time. The K/S value increased with increasing dyeing concentration and repeat-numbers. The K/S value increased with increasing dyeing temperature and time, the exhaustion was saturated in $90^{\circ}C\;and\;80min$, respectively. Surface colors of fabrics dyed with pH 3, 7, 11 extract were RP-R-YR-Y range. The light fastness and washing fastness showed good results in Fe-mordanted. The dry leaning fastness appeared more than 4 grade. Rubbing fastness was better in dry methods han that in wet methods. In the result of antibacterial activity, the decrease rate was 9.9% to Staphylococcus aureus with the dyed fabric of cotton.

촉매/$SnO_2$ 가스 센서의 반응 구조에 관한 연구 (A study on the gas reaction mechanism in catalyst/$SnO_2$ gas sensor)

  • 이재홍;김창교;김진걸;조남인;김덕준
    • 한국결정성장학회지
    • /
    • 제7권2호
    • /
    • pp.276-283
    • /
    • 1997
  • 함침법을 이용하여 Pt/$SnO_2$ pellet형 가스 센서를 제조하였다. 제조한 미세 분말에 대하여 전자회절 분석, 투과전자현미경, 주사선전자현미경 등의 분석으로 결정 구조 및 방향성, 결정 크기, 촉매와 담체와의 미세구조 등이 분석되었다. 투과전자현미경 사진으로부터 $400^{\circ}C$에서 하소했을 때 $PtCl_x$에서 Cl의 양이 줄어들고 Pt가 담체인 $SnO_2$속으로 이동되고 있는 것을 보여주었다. 이것이 가스 감지도를 향상시키는 것으로 나타났다. Pt/SnO$_2$시편이 있는 반응기에 $N_2$가스 중에 0.5% $H_2$ 가스를 30 sccm으로 계속 흘려주었을 때 $SnO_2$의 전기 저항은 포화가 이루어 졌으나 $SnO_2$상에 수소 가스의 흡착은 계속되었다. 이는 표면 상태(surface state)가 포화된다는 것을 의미한다. 14 ppm $H_2$가스에 대하여 $300^{\circ}C$에서 81%%의 가스 감지도를 보여주었다.

  • PDF

염화물 환경에서 스테인리스강 용접부의 공식저항성 향상을 위한 마찰교반공정 적용효과에 관한 연구 (A study on the Application Effect of Friction Stir Processing for Enhanced Pitting Corrosion Resistance of Stainless Steel Welds in Chloride Environment)

  • 하종문;심덕남;김승현
    • 한국압력기기공학회 논문집
    • /
    • 제19권2호
    • /
    • pp.84-92
    • /
    • 2023
  • As temporary storage facilities for spent nuclear fuels in domestic nuclear power plants are expected to be saturated, external intermediate storage facilities would be required in the future. Spent nuclear fuels are stored in metal canisters and then placed in a dry environment within concrete or metal casing for operation. In the United States, the dry storage method for spent nuclear fuels has been operated for an extended period. Based on the corrosion experiences of dry storage canisters in chloride environments, numerous studies have been conducted to reduce corrosion in welds. With the construction of intermediate storage facilities in Korea for spent nuclear fuels expected near coastal areas adjacent to nuclear power plants, there is a need for research on the corrosion occurrence of welds and mitigation methods for canisters in chloride environments. In this paper, we measured and compared the residual stresses in the Heat-Affected Zones (HAZ) after electron beam welding (EBW) and gas tungsten arc welding (GTAW) processes for candidate materials such as 304L, 316L, and duplex stainless steel(DSS). We investigated the possibility of microstructure control through the application of surface modification processes using friction stir processing (FSP). Corrosion tests on each welded specimen revealed a higher corrosion rate in EBW welds compared to GTAW. Furthermore, it was confirmed that corrosion resistance improved due to phase refinement and redistribution of precipitates when FSP was applied.

GaAs를 이용한 MIS형 다이오드의 제작 및 전기적 특성 (Fabrication of MIS Type GaAs Diode and Its Electrical Characteristics)

  • 鄭期太;鄭鎬宣
    • 대한전자공학회논문지
    • /
    • 제23권1호
    • /
    • pp.50-57
    • /
    • 1986
  • The fabricatoin sequence of GaAs MIS type diode and its electrical characteristics are presented. Used wafers were undoped GaAS wafer adn Te-doped GaAs wafer. Au and AuGe/Ni was used as schottky contact metal and ohmic contact metal respectively. Oxide layer on GaAs surface was formed by water vapor saturated oxide growth technique and dry oxidation technique. In Te-doped GaAs wafer, cutin voltage of MIS type diode was enhanced about 3V comparing with non-oxide layer diode. From light I-V characteristics fill factor of MIS type Te-doped GaAs diode was about 64%, Voc(open circuit voltage) was 0.67V.

  • PDF

포화(飽和)세멘트 수용액(水溶液)에 의한 추출단당류(抽出單糖類)가 목질(木質)세멘트 복합체(複合體)의 경화(硬化)에 미치는 영향(影響) (Effect of Monosaccharides Extracted by Saturated Portland Cement Solution on the Setting of the Lignocellulosic-Cement Composited)

  • 최돈하;신동소;안원영
    • Journal of the Korean Wood Science and Technology
    • /
    • 제12권3호
    • /
    • pp.25-34
    • /
    • 1984
  • This experiment was carried out to investigate the effects of monosaccharides extracted by saturated portland cement solution on the cement setting in comparision with the inhibitory index (I) of each lignocellulosic-cement system. The wood species which have been widely reforested in Korea, Populus alba-grandulosa, Larix leptolepis, Abies holophylla, Pinus koraiensis, Pinus rigida, Pinus densiflora and agricultural wastes of rice husk and rice stalk were used at this study. The wood meal, 0.50g on dry weight basis, through 0.83 mm(20 mesh) and retained on 0.35mm (40 mesh) screen was extracted by 25 ml saturated portland cement solution and the pH of saturated portland cement solution Was 12.7. To eliminate cation exsisting in the extracted solution, the cation exchange column was used (Fig. 4). Afterwards the extracted monosaccharides were reduced into alditols with sodium borohydride and analyzed by the gas-liquid chromatography for xylan, mannan, arabinan, galactan, gluean. The heat of cement hydration for lignocellulosic-cement system was measured in Dewar flask (Fig. 2). And then the inhibitory indices were calculated from maximum hydration temperature, time and maximum slops of hydration curve of ligno cellulosic-cement systems. The results obtained were as follows; (1) The inhibitory index of pines-Pinus rigida (I=29.33) and Pinus densiflora (I=35.76), were lower than that of poplar-Populus alba-glandulosa (I=41.48), and the index of Larix ieptoiepis (I=73.00) was the highest among eight lignocellulosic-cement systems, and accordingly both Pinus rigida and Pinus des(flora were seemed to be good wood species for wood-cement composite manufacture. (2) In case of Pinus rigida, the inhibitory index was 29.33 and the ratio of the hexoses to the pemoses was 6.04 and in case of Larix leptolepis, the index and the ratio were 73.00 and 35.19, respectively. Therefore the inhibitory index increased with increasing the ratios of the hexoses to the pentoses. (3) The richer amount of xylose and mannose in species caused decreasing the slops of the hydration curve of the lignocellulosic-cement system, prohahly due to the chemical adsorption of the acetyl groups in the hemicellulose on the surface of cement grains. (4) The amoun of xylose and mannose were significant to the inhibitory index of each lignocellulosic-cement system but any specific relation between the amount of glucose and inhibitory index was not found.

  • PDF

저변형률시험법에 의한 섬유강화 복합재료의 응력부식균열에 관한 연구 (A Study on Stress Corrosion Cracking of Fiber Reinforced Composite by Slow Strain Rate Test)

  • 임재규;최태수
    • 대한기계학회논문집A
    • /
    • 제20권11호
    • /
    • pp.3433-3440
    • /
    • 1996
  • This paper was investigation of the stres corrosion cracking(SCC) mechanism and the properties of corrosion fracture surface of glass fiber reinforced plastics(GFRP) produced by hand lay up(HLU) method in synthetic sea water. Test material is GFRP, that was used vinylester type epoxy acrylate resin and an unsaturated polyester as the matrix and the chopped strand mat(CSM) type E-glss fiber as the reinforcement. The slow strain rate test(SSRT) was performed on dry, wet and saturated wet specimens in sea water. Here the pH concentration of synthetic sea water was 8.2 and the strain rate is 1 x $10^{-6}$($sec^{-1}$) and test temperature ranges varied from $-60^{\circ}C$ to $80^{\circ}C$. It could be confirmed the fact that wet specimens tested at a particular test temperature ranges were appeared the eviences of SCC such as con-planar, mirror and hackle zone. Moreover, SCC of GFRP in sea water was characterised by falt fracture surfaces with only small amounts of fiber pull-out, in partial.

열전달 및 물질전달을 이용한 공극 발열도로에서의 융설 해석에 대한 이론적 연구 (Theoretical Study on Snow Melting Process on Porous Pavement System by using Heat and Mass Transfer)

  • 윤태영
    • 한국도로학회논문집
    • /
    • 제17권5호
    • /
    • pp.1-10
    • /
    • 2015
  • PURPOSES : A finite difference model considering snow melting process on porous asphalt pavement was derived on the basis of heat transfer and mass transfer theories. The derived model can be applied to predict the region where black-ice develops, as well as to predict temperature profile of pavement systems where a de-icing system is installed. In addition, the model can be used to determined the minimum energy required to melt the ice formed on the pavement. METHODS : The snow on the porous asphalt pavement, whose porosity must be considered in thermal analysis, is divided into several layers such as dry snow layer, saturated snow layer, water+pavement surface, pavement surface, and sublayer. The mass balance and heat balance equations are derived to describe conductive, convective, radiative, and latent transfer of heat and mass in each layer. The finite differential method is used to implement the derived equations, boundary conditions, and the testing method to determine the thermal properties are suggested for each layer. RESULTS: The finite differential equations that describe the icing and deicing on pavements are derived, and we have presented them in our work. The framework to develop a temperature-forecasting model is successfully created. CONCLUSIONS : We conclude by successfully creating framework for the finite difference model based on the heat and mass transfer theories. To complete implementation, laboratory tests required to be performed.