• Title/Summary/Keyword: Sampling Range

Search Result 925, Processing Time 0.024 seconds

A Re-configurable 0.8V 10b 60MS/s 19.2mW 0.13um CMOS ADC Operating down to 0.5V (0.5V까지 재구성 가능한 0.8V 10비트 60MS/s 19.2mW 0.13um CMOS A/D 변환기)

  • Lee, Se-Won;Yoo, Si-Wook;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.3
    • /
    • pp.60-68
    • /
    • 2008
  • This work describes a re-configurable 10MS/s to 100MS/s, low-power 10b two-step pipeline ADC operating at a power supply from 0.5V to 1.2V. MOS transistors with a low-threshold voltage are employed partially in the input sampling switches and differential pair of the SHA and MDAC for a proper signal swing margin at a 0.5V supply. The integrated adjustable current reference optimizes the static and dynamic performance of amplifiers at 10b accuracy with a wide range of supply voltages. A signal-isolated layout improves the capacitor mismatch of the MDAC while a switched-bias power-reduction technique reduces the power dissipation of comparators in the flash ADCs. The prototype ADC in a 0.13um CMOS process demonstrates the measured DNL and INL within 0.35LSB and 0.49LSB. The ADC with an active die area of $0.98mm^2$ shows a maximum SNDR and SFDR of 56.0dB and 69.6dB, respectively, and a power consumption of 19.2mW at a nominal condition of 0.8V and 60MS/s.

The development of a bluetooth based portable wireless EEG measurement device (블루투스 기반 휴대용 무선 EEG 측정시스템의 개발)

  • Lee, Dong-Hoon;Lee, Chung-Heon
    • Journal of IKEEE
    • /
    • v.14 no.2
    • /
    • pp.16-23
    • /
    • 2010
  • Since the interest of a brain science research is increased recently, various devices using brain waves have been developed in the field of brain training game, education application and brain computer interface. In this paper, we have developed a portable EEG measurement and a bluetooth based wireless transmission device measuring brain waves from the frontal lob simply and conveniently. The low brain signals about 10~100${\mu}V$ was amplified into several volts and low pass, high pass and notch filter were designed for eliminating unwanted noise and 60Hz power noise. Also, PIC24F192 microcontroller has been used to convert analog brain signal into digital signal and transmit the signal into personal computer wirelessly. The sampling rate of 1KHz and bluetooth based wireless transmission with 38,400bps were used. The LabVIEW programing was used to receive and monitor the brain signals. The power spectrum of commercial biopac MP100 and that of a developed EEG system was compared for performance verification after the simulation signals of sine waves of $1{\mu}V$, 0~200Hz was inputed and processed by FFT transformation. As a result of comparison, the developed system showed good performance because frequency response of a developed system was similar to that of a commercial biopac MP100 inside the range of 30Hz specially.

Bioequivalence of Efexor® XR capsule to Venfaxine® OR tablet (Venlafaxine 75 mg) (이팩사® XR서방캅셀(벤라팍신, 75 mg)에 대한 벤팍신®OR서방정의 생물학적동등성)

  • Aryal, Dipendra Kumar;Oh, Soo-Yeon;Cho, Jong-Tae;Kim, Hyung-Gun;Kim, Yoon-Gyoon
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.6
    • /
    • pp.397-402
    • /
    • 2007
  • To evaluate the bioequivalence of two venlafaxine formulations, a standard 2-way randomized cross-over study was conducted in twenty-four healthy male Korean volunteers. A single oral dose of 75 mg of test formulation Venfaxine $OR^{(R)}$ (tablet) or reference formulation Efexor $XR^{(R)}$ (capsule) was administered with one-week washout period. Plasma concentrations of venlafaxine were assayed for over a period of 72 hours with a well validated method using liquid chromatography coupled to tandem mass spectrometry (LC-MS-MS). The $mean{\pm}S.D$. of maximum concentration $(C_{max})$ and elimination half-life $(t_{1/2})$ were $64.7{\pm}28.5$ ng/mL, $9.2{\pm}3.0$ h, and $67.2{\pm}30.2$ ng/mL, $9.9{\pm}3.5$ h for test and reference formulations, respectively. Time to reach maximum concentration $(T_{max})$ expressed in median value (range), for the test and the reference, were 10 h (6-14) and 8h (4-12), respectively. Similarly, area under the plasma concentration-time curve, from time zero to last sampling time $(AUC_t)$ and from time zero to time infinity $(AUC_{inf})$, for test and reference formulations were $1185{\pm}755$, $1326{\pm}896$ and $1124{\pm}737$, $1185{\pm}755$ $ng{\cdot}h/mL$, respectively. The parametric 90% confidence intervals on the mean of the differences between the two formulations (test-reference) of the log transformed values of $AUC_t$, and $C_{max}$ were 0.9630 to 1.1383 and 0.8650 to 1.0446, respectively. The overall results indicate that the two formulations are bioequivalent and can be prescribe interchangeably.

Mobility of pesticides in different soil textures and gravel contents under soil column (토양 column을 이용한 토성 및 자갈함량별 농약 이동특성)

  • Lee, Sang-Min;Kim, Seong-Soo;Park, Dong-Sik;Hur, Jang-Hyun
    • The Korean Journal of Pesticide Science
    • /
    • v.9 no.4
    • /
    • pp.330-337
    • /
    • 2005
  • This study was investigated to elucidate the pesticide mobility in three different soil textures(Heongseong sandy loam; Chuncheon, loam; Taeback, silty clay loam) and four different gravel contents(0, 20, 40, 60%) of Taebaek soil using soil column. Carbofuran, which ranks the highest water solubility among 7 pesticides(carbendazim, carbofuran, chlorpyrifos, cypermethrin, dimethomorph, diniconazole and endosulfan) was defected over 87% in leachate samples within all soil types from early sampling time. Amount of 5 residual pesticides excluding carbendazim and carbofuran were ordered silty clay loam > loam > sandy loam, indicating pesticide residues are related to percentage of clay contents in soils. Comparing the amount of residual pesticides in soil column(upper, middle and lower layer), 6 pesticides apart from carbofuran were found in the range of $50{\sim}92%$ on the upper layer of silty clay loam and loam. Mobility of pesticides either in soil or leachate samples is dependant on water solubility of pesticide and clay content of soil. The results obtained from four different gravel contents of Tacback soil were similar to the results of three different soil textures. Also it was found that more the gravel contents, faster the flow velocity of leachate water. These results possibly provide an idea to select proper pesticides and to reduce soil and water contamination at alpine and sloped-land.

Cost Comparison of PWR and PHWR Nuclear Power Plants in Korea

  • Kim, Chang-Hyo;Chung, Chang-Hyun;So, Dong-Sub
    • Nuclear Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.263-274
    • /
    • 1979
  • A statistical approach is used to investigate the relative economic advantages of pressurized water reactor (PWR) and pressurized heavy water reactor (PHWR-CANDU) nuclear power plants for hypothetical 900Mwe systems with the throwaway fuel cycle to be built in the Republic of Korea. Power cost is decomposed into the cost components related to the plant capital, operation and maintenance, working capital requirements and fuel cycle operation. The calculation of construction cost is performed with the modified version of computer code ORCOST, and the modified POWERCO-50 is used to evaluate the cost components. Most of economic parameters are treated as statistical variables, each being given with a certain range. Through a random sampling procedures. the probability histograms on unit plant construction costs and power generating costs are obtained. The power cost probability histograms of the PWR and the PHWR plants overlap considerably, and the power costs of two systems appear to be almost same with the PHWR power cost being 0.4mil1/kwh lower compared with 39.4 mills/kwh for the PWR plant (July 1986 US-dollars). When a construction period of PHWR plant is longer by one year than that of PWR plant, there is no difference in the unit power cost of two plants. This comparison leads to no definite conclusion on the cost advantage of the PWR plant versus the PHWR plant. We conclude that the selection issue of nuclear power plants in Korea still remains an open question and that future effort to solve this question should be made toward economic quantification of those factors such as technology transfer and localization.

  • PDF

Exposure Characteristics of Construction Painters to Organic Solvents

  • Park, Hyunhee;Park, Hae Dong;Jang, Jae-Kil
    • Safety and Health at Work
    • /
    • v.7 no.1
    • /
    • pp.63-71
    • /
    • 2016
  • Background: Construction painters have not been studied well in terms of their hazards exposure. The objective of this study was to evaluate the exposure levels of total volatile organic compounds (TVOCs) for painters in the construction industry. Methods: Activity-specific personal air samplings were carried out in three waterproofing activities [polyurethane (PU), asphalt, and cement mortar] and three painting activities (epoxy, oil based, and water based) by using organic-vapor-monitor passive-sampling devices. Gas chromatograph with flame ionization detector could be used for identifying and quantifying individual organic chemicals. The levels of TVOCs, by summing up 15 targeted substances, were expressed in exposure-index (EI) values. Results: As arithmetic means in the order of concentration levels, the EIs of TVOCs in waterproofing works were 10.77, 2.42, 1.78, 1.68, 0.47, 0.07, and none detected (ND) for indoor PU-primer task, outdoor PU-primer task, outdoor PU-resin task, indoor PU-resin task, asphalt-primer task, asphalt-adhesive task, and cement-mortar task, respectively. The highest EI for painting works was 5.61 for indoor epoxyprimer task, followed by indoor epoxy-resin task (2.03), outdoor oil-based-spray-paint task (1.65), outdoor water-based-paint task (0.66), and indoor oil-based-paint task (0.15). Assuming that the operations were carried out continuously for 8 hours without breaks and by using the arithmetic means of EIs for each of the 12 tasks in this study, 58.3% (7 out of 12) exceeded the exposure limit of 100% (EI > 1.0), while 8.3% (1 out of 12) was in 50e100% of exposure limit (0.5 > EI > 1.0), and 4 tasks out of 12 were located in less than 50% of the limit range (EI < 0.5). Conclusion: From this study, we recognized that construction painters are exposed to various solvents, including carcinogens and reproductive toxins, and the levels of TVOC concentration in many of the painting tasks exceeded the exposure limits. Construction workers need to be protected from chemical agents during their painting works by using personal protective devices and/or work practice measures. Additional studies should focus on the exposure assessment of other hazards for construction workers, in order to identify high-risk tasks and to improve hazardous work environments.

Effect of Lugol's Iodine Preservation on Cyanobacterial Biovolume and Estimate of Live Cell Biovolume Using Shrinkage Ratio (Lugol's Iodine Solution 첨가 후 보존 기간별 남조류 세포부피 변화 및 수축비를 이용한 생세포 부피 산정)

  • Park, Hae-Kyung;Lee, Hyeon-Je;Lee, Hae-Jin;Shin, Ra-Young
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.4
    • /
    • pp.375-381
    • /
    • 2018
  • The monitoring of phytoplankton biomass and community structure is essential as a first step to control the harmful cyanobacterial blooms in freshwater systems, such as seen in rivers and lakes, due to the process of eutrophication and climate change. In order to quantify the biomass of phytoplankton with a wide range in size and shape, the measurement of cell biovolume along with cell density is required for a comprehensive review on this issue. However, most routine monitoring programs preserve the gathered phytoplankton samples before analysis using chemical additives, because of the constraint of time and the number of samples. The purpose of this study was to investigate the cell biovolume change characteristics of six cyanobacterial species, which are common bloom-causing cyanobacteria in the Nakdong River, after the preservation with Lugol's iodine solution. All species showed a statistically significant difference after the addition of Lugol's iodine solution compared to the live cell biovolume, and the cell biovolume decreased to the level of 34.0 ~ 56.3 % at maximum in each species after the preservation. The nonlinear regression models for determining the shrinkage ratio by a preservation period were derived by using the cell biovolume measured until 180 days preservation of each target species, and the equation to convert the cell biovolume measured after preservation for a certain period to the cell biovolume of viable cell was derived using that formula. The conversion equation derived from this study can be used to estimate the actual cell biovolume in the natural environment at the time of sampling, by using the measured biovolume after the preservation in the phytoplankton monitoring. Moreover this is expected to contribute to the final interpretation of the water quality and aquatic ecosystem impacts due to the cyanobacterial blooms.

Discontinuity Analysis Method using Reverse Engineering (역분석공학기법을 이용한 불연속면 분석 프로그램 개발)

  • Park, Eui-Seob;Jung, Yong-Bok;Ryu, Chang-Ha;SunWoo, Choon;Choi, Yong-Kun;Heo, Sung;Cheon, Dae-Sung
    • Tunnel and Underground Space
    • /
    • v.17 no.3 s.68
    • /
    • pp.165-174
    • /
    • 2007
  • The technique, which reproduces the figures of objects from measured data of the objects using 3-D laser scanner, is called reverse engineering. Recently, research studies into applications of reverse engineering to rock engineering are increasing in number, in the discontinuity surveys for rock slopes out of man's reach, or rapid discontinuity surveys for wide range areas. For analysis of discontinuity using reverse engineering, a program for processing point clouds data from the 3-D laser scanner, for sampling from these point clouds data, and finally analyzing the discontinuity is needed. However, existing programs rarely have sufficient functions to properly analyze the discontinuities. In this study, a program was developed, which can automatically sample discontinuities from the point clouds data which measured in a rock slope using a 3-D laser scanner, and which can also undertake statistical analysis of the discontinuities. This developed program was verified by the application of discontinuity surveys in a rock slope and a tunnel. By undertaking the discontinuity survey using a 3-D laser scanner and the developed program, the feasibility and rapidity of such surveys is expected to improve in areas out of man's reach in geotechnical surveys. Taking into consideration the fact that the international level of related techniques is at a rudimentary stage, the possibility of prior occupation of a broad market is also expected.

Evaluation of Effective Dose and Exposure Levels of Radon in Office and Plant Buildings (일부 제조업 사업장의 사무 및 공장동에서의 라돈농도 수준 및 유효선량 평가)

  • Chung, Eun Kyo;Kim, Ki Woong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.1
    • /
    • pp.38-45
    • /
    • 2017
  • Objectives: Radon may be second only to smoking as a cause of lung cancer. Radon is a colorless, tasteless radioactive gas that is formed via the radioactive decay of radium. Therefore, radon levels can build up based on the amount of radium contained in construction materials such as phospho-gypsum board or when ventilation rates are low. This study provides our findings from evaluation of radon gas at facilities and offices in an industrial complex. Methods: We evaluated the office rooms and processes of 12 manufacturing factories from May 14, 2014 to September 23, 2014. Short-term data were measured by using real-time monitoring detectors(Model 1030, Sun Nuclear Co., USA) indoors in the office buildings. The radon measurements were recorded at 30-minute intervals over approximately 48 hours. The limit of detection of this instrument is $3.7Bq/m^3$. Also, long-term data were measured by using ${\alpha}-track$ radon detectors(${\alpha}-track$, Rn-tech Co., Korea) in the office and factory buildings. Our detectors were exposed for over 90 days, resulting in a minimum detectable concentration of $7.4Bq/m^3$. Detectors were placed 150-220 cm above the floor. Results: Radon concentrations averaged $20.6{\pm}17.0Bq/m^3$($3.7-115.8Bq/m^3$) in the overall area. The monthly mean concentration of radon by building materials were in the order of gypsum>concrete>cement. Radon concentrations were measured using ${\alpha}-track$ in parallel with direct-reading radon detectors and the two metric methods for radon monitoring were compared. A t-test for the two sampling methods showed that there is no difference between the average radon concentrations(p<0.05). Most of the office buildings did not have central air-conditioning, but several rooms had window- or ceiling-mounted units. Employees could also open windows. The first, second and third floors were used mainly for office work. Conclusions: Radon levels measured during this assessment in the office rooms of buildings and processes in factories were well below the ICRP reference level of $1,000Bq/m^3$ for workplaces and also below the lower USEPA residential guideline of $148Bq/m^3$. The range of indoor annual effective dose due to radon exposure for workers working in the office and factory buildings was 0.01 to 1.45 mSv/yr. Construction materials such as phospho-gypsum board, concrete and cement were the main emission sources for workers' exposure.

Development of the PC Based Color Fish Finder (퍼스널 컴퓨터를 이용한 칼라 어군탐지기의 개발에 관한 연구)

  • 신현옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.31 no.3
    • /
    • pp.247-255
    • /
    • 1995
  • This paper describes a personal computer(PC) based color fish finder to improve some problem of the commercial one. The commercial fish finder has no function of the echo data logging and replaying. The authors developed two types of the PC based color fish finder. One is a master type composed of a PC, a digital input-output board, and analog to digital converting (A/D) board and an ultrasonic transceiver unit, the other is a slave type composed of a PC and an A/D board. To test the performances of the master type experiments were carried out in air and in a water tank. It is found that the designed master type fish finder displays very well an eight-colored echogram by one dot resolution to the left side of the PC monitor. Also, the depth of echo signal was corresponds very well to the range from the transducer to a target. The sampling interval of echo signal is about 0.1m and the time of A/D conversion is 30 $\mu$sec. On the other hand, to test the performances of the slave type a raw data of echo signals from a data logger was supplied directly or via RF transceivers to the slave type one. From this experiment, it is confirmed the slave type is useful to replay the echo signal from the data logger or a telesounder.

  • PDF