• 제목/요약/키워드: Sampler

검색결과 878건 처리시간 0.025초

확산형포집기(3M OVM #3500)와 활성탄관의 유기용제 포집농도 비교 및 확산형포집기의 현장 적용 가능성 (Comparison between the Charcoal Tube Sampling Method and the Diffusive Sampler, and the Applicability of Diffusive Sampler in the Field)

  • 장성호;김형아
    • 한국산업보건학회지
    • /
    • 제15권3호
    • /
    • pp.261-269
    • /
    • 2005
  • To investigate the field applicability of a diffusive sampler (3M OVM #3500, passive sampling method) authors conducted a simultaneous measurement of personal organic solvents exposure in the air of the workplaces by charcoal tube with low volume sampler (active sampling method) and diffusive sampler. Samples were collected and analyzed by NIOSH method ($NMAM^{(R)}$) from thirty-eight workers in 12 factories who work in 6 different processes. Geometric mean (GM) and geometric standard deviation (GSD) were used to describe the result. To compare the results of the two methods, paired t-test was used. According to the manual of the exposure assessment of the mixed organic solvents (Ministry of Labor, Korea), Em was calculated. Simple linear regression was used to evaluate the relationship between the two methods. Results were as follows; 1. Eight different solvents (ethyl acetate, n-hexane, toluene, xylene, acetone, isopropyl alcohol, methyl ethyl ketone (MEK), and methyl isobutyl ketone) were detected simultaneously in the two methods and the concentrations of the personal exposure were lower than 0.5 TLV level. The concentration of the charcoal tube method was higher than that of a diffusive sampler in n-hexane and MEK (p<0.05). 2. Em of the charcoal tube method was higher than that of diffusive sampler method but not significantly different and was lower than the OEL (Occupational Exposure Limit) in all 6 processes. 3. There was a significant correlation between the two methods in low concentrations of the 8 organic solvents (p<0.05). In conclusion, there was no difference in charcoal tube method and diffusive sampler method in low concentrations of some organic solvents, diffusive sampler can be applied to assess the personal monitoring in low level exposure.

익산지역에서 자동 및 수동채취방식에 따른 강수의 화학적 특성 비교 (Comparison of Chemical Characteristics in Wet and Bulk Precipitation Collected in the Iksan Area)

  • 강공언
    • 한국대기환경학회지
    • /
    • 제20권3호
    • /
    • pp.381-396
    • /
    • 2004
  • In order to understand the precipitation acidity and chemical composition of ion species in Iksan area as well as to know the difference of chemical characteristics in precipitation samples from the viewpoint of precipitation sampling method, precipitation samples were collected by wet-only automatic precipitation sampler and bulk manual precipitation sampler in Iksan, from March 2003 to August 2003. The mean pH of precipitation was 5.0. There was a little significant difference in the mean value of pH between automatic and manual sampler. However, pH values of some precipitation samples were lower in automatic sampler than in manual sampler, especially in case of precipitation samples with small rainfall for March 2003. The mean concentrations of each ions in precipitation were generally a little higher in precipitation samples collected by the manual sampler than in those collected by the automatic sampler because of accumulation of dry deposition on the surface of glass funnel installed at the manual sampler during the sampling period or no rainfall. Dominant species determining the acidity of precipitation, were N $H_4$$^{[-10]}$ and nss-C $a^{2+}$ for cations and nss-S $O_4$$^{2-}$ and N $O_3$$^{[-10]}$ for anions. The mean concentration of N $H_4$$^{+}$ and nss-C $a^{2+}$ were 31 $\mu$eq/L and 9 $\mu$eq/L for the automatic sampler and 40 ueq/L and 16 ueq/L for the manual sampler, respectively. In addition, nss-S $O_4$$^{2-}$ and N $O_3$$^{[-10]}$ were 27 $\mu$eq/L and 13 $\mu$eq/L for the automatic sampler and 32 $\mu$eq/L and 17 $\mu$eq/L for the manual sampler, respectively. Although the concentrations of the acidifying ions of nss-S $O_4$$^{2-}$ and N $O_3$$^{[-10]}$ were about 3 times higher than those for foreign pristine sites, precipitation acidity were estimated to be natural due to the neutralization reaction of the alkaline species of N $H_4$$^{+}$ and nss-C $a^{2+}$ with its higher concentrations. Considering the ratios of nss-S $O_4$$^{2-}$/N $O_4$$^{[-10]}$ nss-S $O_4$$^{2-}$, it was found that ammonium sulphate was dominant in Iksan precipitation. The major non-sea salt ions were maximum concentrations for March, but decreased with increasing of precipitation amount.on amount.

A Comparison of Nicotine Diffusive Sampler and XAD-4 Tube for Determination of Nicotine in ETS

  • Kim, Hyo-Cherl;Paik, Nam-Won;Kim, Kyoung-Ran;Kim, Kyoung-Su;Lee, Kyoung-Suk;Cho, Kyung-Ah
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2005년도 국제학술대회
    • /
    • pp.371-372
    • /
    • 2005
  • Active sampler has been widely used to measure nicotine concentration in air. The experiments were conducted to compare the active sampler method with diffusive sampler in exposure chamber and smoking areas, respectively. The result of these tests that indicated that passive sampler can be used instead of active sampler in ETS, because coefficient of determination was 0.9292 between active and passive sampling in smoking area

  • PDF

Evaluation of an Ammonia Passive Sampler Using Chamber System

  • Yim, Bong-Been;Kim, Sun-Tae
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제22권E1호
    • /
    • pp.1-8
    • /
    • 2006
  • The purpose of this study was to evaluate the efficiency of a passive sampler in measuring atmospheric ammonia concentrations using chamber system. The ability of the passive sampler to quantitatively determine atmospheric ammonia gas was almost identical to that of the reference method (indophenol method). There was no significant difference between concentrations measured by the two methods. The detection and quantification limits of the ammonia passive sampler were 16.9 ppb and 25.3 ppb, respectively, for a 24-h sampling period. The average coefficient of variation between replicated samplers was $6.7{\pm}4.2%$. The concentrations measured by the two methods (passive sampler and indophenol method) were no significant difference with good a correlation (correlation coefficient=0.964).

A Low-Cost Open-Source Air Sampler for the Sorbent Tube Sampling for TD-GC/MS Analysis

  • Jang, Hwa-yong;Oh, Han Bin
    • Mass Spectrometry Letters
    • /
    • 제11권4호
    • /
    • pp.95-102
    • /
    • 2020
  • In this study, we provide full descriptions of how to make a low-cost and completely open-source laboratory-made air sampler that will be used for sample adsorption for thermal desorption-gas chromatography mass spectrometry (TD-GC/MS) analysis. It is well known that harmful gases cause bad effects on human bodies, so it is necessary to identify the types and amounts of gases in industrial sites. One of the most commonly used methods for gas sampling is to utilize a sorbent tube using an air sampler. Commercially available air samplers are expensive, typically priced between $1,000 and $2,000, and their design often cannot be modified to fit the experiment. To address these shortcomings, we have developed a do-it-yourself (DIY) air sampler that is not only cheap enough, but also completely open-source. Furthermore, the performance of the fabricated air sampler was validated in conjunction with TD-GC/MS for the analysis of volatile compounds.

테들러 백 샘플러의 대체 소재로서 폴리에스터 알루미늄 백에 대한 예비연구: 환원황화합물을 중심으로 (A Preliminary Study on Polyester Aluminum Bag as the Possible Substitute for Tedlar Bag Sampler in RSC Analysis)

  • 김기현;조상희
    • 한국대기환경학회지
    • /
    • 제27권4호
    • /
    • pp.454-459
    • /
    • 2011
  • In this study, the recovery rate of Tedlar bag (T) sampler was investigated in comparison to polyester aluminum bag (P) sampler. To derive the comparative data sets for the relative performance between different samplers, a series of calibration experiments were performed by using 1 ppb standard of four offensive reduced sulfur compounds (RSC) odorants ($H_2S$, $CH_3SH$, DMS, and DMDS) along with $SO_2$ and $CS_2$. All the analysis was made by gas chromatography/pulsed flame photometric detector (GC/PFPD) combined with air server/thermal desorber (AS/TD). The measurement data were obtained by loading gaseous standards (1 ppb) at 3 injection volumes (250, 500 and 1,000 mL) at three intervals (0, 24 and 72 hrs). The recovery rates (RR) of P sampler were computed against the slope values of T sampler. According to our analysis, P sampler exhibits slightly enhanced loss relative to T, especially with light RSCs ($H_2S$ and $CH_3SH$). At day 0, RR for the two were 88 and 85%, respectively. Such reduction proceeded rather rapidly in the case of $H_2S$ through time. However, P sampler was more stable to store $SO_2$ unlike others. Despite slightly reduced recovery, P sampler appears as a good replacement of T sampler.

시료의 채취 방식에 따른 교란도 평가 (Evaluation of Disturbance of Clay Samples Due to Sampling Methods)

  • 윤여원;김영진;최은호
    • 한국지반환경공학회 논문집
    • /
    • 제9권1호
    • /
    • pp.27-31
    • /
    • 2008
  • 본 연구는 직경 225mm의 KICT 대구경 샘플러와 NX size 피스톤 샘플러를 사용하여 채취한 점토시료의 강도정수를 비교하여 대구경 샘플러가 NX size 피스톤 샘플러에 비해 원지반 상태를 얼마나 잘 반영하는가를 평가하는데 그 목적이 있다. 이 연구를 위하여 두 가지 샘플러로 채취한 점토 시료를 동일 조건에서 표준압밀시험, 일축압축시험, 삼축압축시험을 수행하여 채취 시료의 교란도 분석을 하였다. 분석결과 초기간극비와 선행압밀응력 뿐만 아니라 시료의 일축 및 삼축압축 시험에 의한 강도정수도 KICT 대구경 샘플러에 의한 시료가 약 10% 이상 높게 나타났다.

  • PDF

Development of a PM Sampler for Collecting Fine Particles via Condensation Magnification

  • Kim, D.S.;Kang, C.H.;Hong, S.B.;Lee, K.W.;Lee, J.H.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제24권E1호
    • /
    • pp.24-31
    • /
    • 2008
  • In this study, a new PM (particulate matter) sampler was developed and fabricated to collect fine particles in the atmosphere, and laboratory and field tests were carried out to evaluate the performance of the sampler. The PM sampler, which was based on impingers, employed an aerosol condensation system as a PM magnifier to improve its collection efficiencies. Sodium chloride, ammonium sulfate and ammonium nitrate aerosols were used as test particles, because these components are rich in ambient aerosols. As a result, it was found that the collection efficiency of the novel PM sampler was very high. Thus, it is believed that the PM sampler is an effective device for sampling fine particles. In addition, it was demonstrated that this work could contribute to the collection or removal of fine particles and be applied to the semicontinuous sampling of ambient aerosols for chemical composition analysis.

MTDFREML 방법과 Gibbs Sampling 방법에 의한 한우의 육질형질 유전모수 추정 (Estimation of Genetic Parameter for Carcass Traits According to MTDFREML and Gibbs Sampling in Hanwoo(Korean Cattle))

  • 김내수;이중재;주종철
    • Journal of Animal Science and Technology
    • /
    • 제48권3호
    • /
    • pp.337-344
    • /
    • 2006
  • 본 연구는 Gibbs sampler와 MTDFREML 방법에 의해서 한우 도체형질의 유전력 및 유전(공)분산을 단형질 및 다형질 개체모형을 가지고 추정하고 비교 하였다. 배장근단면적(longissimus dorsi area), 등지방 두께(backfat thickness), 상강도(marbling score)의 유전 모수를 추정하였으며, 분석에 이용된 자료는 총 1,941두 이고, 혈연계수를 구하기 위한 혈통 자료는 23,058두를 이용하였다. 도체형질에 대한 유전력 추정 시 단형질과 다형질 개체모형에 의한 편차는 크게 나타나지 않았다. 단형질 개체모형에서 Gibbs sampler 방법을 이용한 추정에서는 LDA, BF 및 MS에서 각각 0.52, 0.59 및 0.42로서 고도의 유전력을 보였다. MTDFREML 방법을 통한 추정 시에는 LDA 0.41, BF 0.52로서 고도의 유전력을 보였으며, MS는 0.32로서 중도의 유전력을 보였다. 분석 방법에 의한 유전력 추정은 Gibbs sampler에 의한 방법이 MTDFREML에 의한 방법에 비해서 0.1정도 높게 추정되었다. MTDFREML 방법과 Gibbs Sampler 방법에 의한 도체 형질간의 유전상관은 LDA와 BF, MS 간에는 모두 부의 상관을 보였고, BF과 MS에서는 정의 상관을 보였다. MTDFREML과 Gibbs Sampler에서 이들의 분석 방법 간에 육종가 추정치에 대한 상관계수는 LDA와 BF에서는 0.989 이상의 높은 추정치를 보였으나, MS에 대해서는 이보다 다소 낮은 0.985를 나타내었다. 그리하여, 상강도(marbling score)와 같은 범주형 자료에 대한 유전분석은 기존의 선형의 정규분포를 가정한 REML방법에 의한 것 보다 범주형 모형을 설정하여 Gibbs sampling algorithm을 응용한 분석방법이 더 적합할 것으로 사료된다.

Gent sampler와 High-volume air sampler의 분진 농도 비교연구 (Comparison of PM 10 concentration between Gent Sampler and High-volume air sampler)

  • 임종명;이현석;장미숙;이진홍
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2003년도 춘계학술대회 논문집
    • /
    • pp.275-276
    • /
    • 2003
  • 산업의 발달에 따른 환경 오염물질의 증가와 오염물질의 종류가 다양화됨에 따라 대기 중의 유해원소 및 미량원소에 의한 환경오염과 그로 인한 인체건강에 대한 영향은 인간생활에 심각한 문제가 되므로 대기 중의 농도를 정확히 측정하는 것은 매우 중요한 일이다. 특히 미세 입자는 오염된 도심지역 분진수의 90∼99%에 이르는 높은 비율을 보이고 있고, 폐 깊숙이 침투하여 폐암을 비롯한 폐질환을 일으킬 수 있다. (중략)

  • PDF