Evaluation of Disturbance of Clay Samples Due to Sampling Methods

시료의 채취 방식에 따른 교란도 평가

  • 윤여원 (인하대학교 사회기반시스템공학부) ;
  • 김영진 (한국건설기술연구원) ;
  • 최은호 (인하대학교 대학원)
  • Received : 2007.11.22
  • Accepted : 2007.12.17
  • Published : 2008.01.01

Abstract

In this study, evaluation of samples' reflection of in-situ condition was performed for those by 225 mm KICT large sampler and NX size piston sampler. Disturbance analysis was conducted for the clay sampled by two kinds of sampler throughout consolidation tests, uniaxial tests and triaxial test, under the same condition. From the analysis it can be seen that not only the initial void ratio and preconsolidation pressure from KICT large sampler but strength parameters from both uniaxial and triaxial compression tests are also about 10% higher than those of NX size piston sampler's.

본 연구는 직경 225mm의 KICT 대구경 샘플러와 NX size 피스톤 샘플러를 사용하여 채취한 점토시료의 강도정수를 비교하여 대구경 샘플러가 NX size 피스톤 샘플러에 비해 원지반 상태를 얼마나 잘 반영하는가를 평가하는데 그 목적이 있다. 이 연구를 위하여 두 가지 샘플러로 채취한 점토 시료를 동일 조건에서 표준압밀시험, 일축압축시험, 삼축압축시험을 수행하여 채취 시료의 교란도 분석을 하였다. 분석결과 초기간극비와 선행압밀응력 뿐만 아니라 시료의 일축 및 삼축압축 시험에 의한 강도정수도 KICT 대구경 샘플러에 의한 시료가 약 10% 이상 높게 나타났다.

Keywords

Acknowledgement

Supported by : 한국건설기술연구원