• Title/Summary/Keyword: Sample thickness

Search Result 809, Processing Time 0.044 seconds

Studies on Nanostructured Amorphous Carbon by X-ray Diffraction and Small Angle X-ray Scattering

  • Dasgupta, K.;Krishna, P.S.R.;Chitra, R.;Sathiyamoorth, D.
    • Carbon letters
    • /
    • v.4 no.1
    • /
    • pp.10-13
    • /
    • 2003
  • The structural studies of amorphous isotropic carbon prepared from pyrolysis of phenol formaldehyde resin have been carried out using X-ray diffraction. X-ray diffraction from as prepared sample at $1000^{\circ}C$ and a sample treated at $1900^{\circ}C$ revealed that both are amorphous even though there are small differences in short range order. It is found that both are graphite like carbon (GLC) with predominantly $sp^2$ hybridization. Small angle X-ray scattering results show that as prepared sample mainly consists of thin two dimensional platelets of graphitic carbon whereas they grow in thickness to become three dimensional materials of nano dimensions.

  • PDF

A Novel Method for Material Rendering and Real Measurement of Thickness Using Ultrasound (초음파를 이용한 실측 두께 측정과 재질 렌더링)

  • Choi, Taeyoung;Chin, Seongah
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.6
    • /
    • pp.190-197
    • /
    • 2014
  • In this paper, we present a method for optical parameter-based material rendering with measuring the thickness of a material using ultrasonic waves. Thickness is an important element in determining the reflectance and transmittance of a material along with its optical characteristics and plays a crucial role in more realistic object rendering. In studies conducted thus far, thickness has been measured and used for rendering. The proposed method is a novel method attempted for the first time ever to render a material considering the thickness of a material whose thickness cannot be measured by visual assessment, using ultrasonic waves. It was implemented by measuring the sound velocity of the reference sample and applying the results to the thickness measurement of other objects that have the same characteristics. The characteristics of the objects measured are reflected in the quality of the final rendering, thus verifying the importance of thickness in rendering.

Correlation analysis of central corneal thickness, anterior chamber volume, and anterior chamber depth of 20 to 24 Years old population in Korea (한국인 20세부터 24세까지의 중심 각막 두께, 앞방 부피, 앞방 깊이에 대한 상관관계 분석)

  • Sang Yeul Park;Douk Hoon Kim
    • Journal of Korean Clinical Health Science
    • /
    • v.12 no.1
    • /
    • pp.1654-1659
    • /
    • 2024
  • Purpose: The aim of this study was to determine Correlation analysis of central corneal thickness, anterior chamber volume, and anterior chamber depth in Koreans aged 20 to 24 years using the Pentacam tool. Methods: The subjects of this study were 53 Korean adults with healthy eyes. The central corneal thickness(CCT), anterior chamber volume(ACV), and anterior chamber depth(ACD) was measured with Pentacam device. Data was analyzed by means of the Pearson's correlation cofficient. P-values<0.001 were considered statistically significant. Results: Mean age of subjects was 22.0±2.01 years. The mean +/- central corneal thickness of the right eye and left eye were 546.66±32.221mmg and 545.70±32.759mm, respectively. Also The mean central cornea thickness was 546.19 um in the whole sample. The mean anterior chamber volume the right eye and left eye was 181.66±33.738 mm3 and 180.12±30.84 mm3, respectively. The mean anterior chamber depth was 3.158±0.257 mm and 3.122±0.233 mm in right eye and left eye, respectively. There was a statistically significant difference between anterior camber volume and anterior chamber depth(p<0.001, Pearson's correlation). However there was no statistically significant difference between central cornea thickness and anterior chamber volume. Also there was no statistically significant difference between central cornea thickness and anterior chamber depth. Conclusion: The results of this study could be used as a clinical reference data for diagnosis and treatment of cornea in Korean adolescents.

CHARACTERIZATION AND CLASSIFICATION BY NEAR INFRARED SPECTROSCOPY OF WAXES USED IN DAIRY TECHNOLOGY

  • Barzaghi, Stefania;Giardina, Claudia;Cattaneo, Tiziana M.P.;Giangiacomo, Roberto
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1252-1252
    • /
    • 2001
  • The aim of this study was to evaluate the possibility to characterize and classify waxes applied on some type of cheeses to obtain good stability during handling and transportation. Generally, waxes are obtained from the petrochemical industry, nowadays there is the possibility to also use biodegradable waxes produced from microorganisms. Preliminary studies were carried out to optimize sample presentation in NIR analysis, such as melting conditions (influence of temperature) and coat thickness of wax. 12 waxes (biodegradable or not) were analysed by using an InfraAlyzer 500 (Bran+Luebbe). The sample size was performed cutting pieces of 1.5 cm (height) x 1.5 cm (width) x 1.5 mm (thickness), previously melted at 9$0^{\circ}C$. NIR spectra were collected at room temperature, and data were processed by Sesame Software (Bran+Luebbe) to evaluate qualitative differences among samples by cluster analysis. Waxes were gathered on the basis of their origin (petrochemical or microbial). To better understand the significance of the NIRS bands discriminating among waxes, a two-dimensional correlation with FT-IR spectra, collected by a FT-IR/ATR 420 (JASCO) instrument, was made using 2DCORR program (Galactic Industries). On the basis of its classification power, NIRS appears to be a promising tool when used in routine analysis for a qualitative control of raw materials.

  • PDF

Development of Core Material with High Magnetic Induction and Low Iron Loss for Middle-Frequency Applications (고자속밀도와 저손실 특성을 갖는 중주파수대 철심재료 개발 및 응용)

  • Cho, Seong-Soo;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.190-195
    • /
    • 2009
  • Thin-gauged 3% silicon steel sheets having a highly grain-oriented texture have been developed as a core material for applications of middle-frequency (400 Hz ${\sim}$ 10 kHz) devices. The newly developed sheets with a tension coating showed an excellent reduction in iron loss at 400 Hz (iron loss at 1.0 T and 400 Hz = 4.677 W/kg, iron loss at 1.5 T and 400 Hz = 9.742 W/kg) due to high magnetic induction, $B_{10}$(measured induction at 1000 A/m), of over 1.9 T. In cases of frequencies below 400 Hz, magnetic induction, $B_{10}$, of the sample plays a major role to reduce its iron loss as excitation induction increases, whereas, in case of frequency of 1 kHz, thickness dependence becomes dominant due to a lower iron loss at relatively thinner sample. The sheets with a high magnetic induction, therefore, are favorable for high excitation induction (over 1.0 T) and low excitation frequency (below 400 Hz) applications, whereas the sheets that can reduce eddy current loss by reducing thickness or domain wall width are advantageous for low excitation induction (below 1.0 T) and high excitation frequency (around 1 kHz) applications.

Magnetic Interaction Effect on Activation Volume and Area of CoPt Magnetic Films (자성막 CoPt의 자기상호작용이 활성화 부피와 면적에 미치는 영향)

  • Kim, Hyeon Soo;Jeong, Soon Young;Suh, Su Jeong
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.6
    • /
    • pp.188-192
    • /
    • 2013
  • The magnetic interaction effect on the magnetic activation volume and area of electrodeposited CoPt magnetic films was investigated. The dipolar interaction was predominant interaction mechanism for all samples. And the interaction strength was increased with decreasing current density and increased with increasing sample thickness. Although the activation volumes of the samples fabricated at low current density were larger than those of the high current density samples, the sample thickness seemed to have little influence on the variation of activation volume. But it was found that the activation area was apparently affected by the magnetic interaction strength as well as the current density.

Ion Beam Assisted Deposition System의 제작 및 자동화

  • 손영호
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1998.02a
    • /
    • pp.27-27
    • /
    • 1998
  • 진공기술의 응용과 진공환경의 이용은 더 이상 논하지 않더라도 산업 전반에 그 충요성이 점점 더 커가고 있다. 이러한 여건에도 불구하고 진공율 이용하는 system 개밟의 국산화는 수 입하는 system으$\mid$ 수에 비하여 절대적으로 부족하며, 또한 개발하는 system의 자동화는 거의 이 루어지지 않고 있으며, 자동화된 진공판련 system은 거의 대부분 수입에 의흔하고 있다. 실험 실 규모에서부터 System올 하나하나 개밭하고, 이톨 자동화하는 노력과 일이 진행됨다면 산업 응용에 있어서도 자연스럽게 자동화된 system으$\mid$ 개발이 이루어 질 것이다 .. system 자동화는 상 품수명의 단축과 이에 따른 다품종 소량을 요구하는 시장수요에 대응하고, 인력절감과 고풀짙 화로 생산성 향상의 요구에 대응하기 위하여 필요하다. 본 연 구에 서 는 e-beam evaporator로 evaporation하면 서 ion beam으로 assist하여 thin film율 제 작하는 IBAD vacuum system율 싫 계 및 제 작하고[1,2], PLC[3,떼톨 이 용하여 system 자동화톨 하였다 .. thin film 제작 process는 먼저 기본 진공상태로 만뚫고 난 뒤, e-beam evaporator로 e evaporation하면서 ion beam source로 assist하여 substrate 011 thin film율 제조한다 226;. thin film올 제 조하면서 thickness monitor로 sample의 thickness rate톨 control 하고, sample의 균얼성과 밀착 성을 고려하여 substrate톨 rotation 및 heating 할 수 있도록 싫계, 제작하였다. 양질의 박막올 제조하기 위해서 진공환경이 좋은 상태로 제공되어야 한다. 이톨 위하여 oil free operation 0 I 가 능한 dry pump와 turbo molecular pump로 고진공 배기 하였다. 진공도의 흑점은 thermal effect 툴 고려하여 cold cathode ion gauge률 사용하였고, intro chamber와 main chamber 사이에는 g gate valve톨 설치하여 벌도로 운용되도록 하였다. 이러한 process를 박막의 두께, 진공도, 시 간, 온도, 공정 동의 조건올 기훈으로 자동화한 것이다. 또한 정전과 단수에 대한 interlock 기능 도 고려하였다.하였다.

  • PDF

Microstructure and Mechanical Properties of a Copper Alloy Sheet Processed by a Differential Speed Rolling (이속압연에 의해 가공된 동합금 판재의 조직 및 기계적 특성)

  • Lee, Seong-Hee
    • Korean Journal of Materials Research
    • /
    • v.22 no.11
    • /
    • pp.581-586
    • /
    • 2012
  • The microstructure and mechanical properties of a copper alloy sheet processed by differential speed rolling (DSR) were investigated in detail. A copper alloy with thickness of 3 mm was rolled to a 50% reduction at ambient temperature without lubrication and with a differential speed ratio of 2.0:1. For comparison, conventional rolling (CR), in which the rolling speeds of the upper and lower rolls is 2.0 m/min, was also performed under the same rolling conditions. The shear strain of the sample processed by CR showed positive values at the positions of the upper roll side and negative values at the positions of the lower roll side. On the other hand, the sample processed by the DSR showed zero or positive shear strain values at all positions. However, the microstructure and mechanical properties of the as-rolled copper alloys did not show such significant differences between the CR and the DSR. The samples rolled by the CR and the DSR exhibited a typical deformation structure. In addition, the DSR processed samples showed a typical rolling texture in which {112}<111>, {011}<211> and {123}<634> components were developed at all positions. Therefore, it is concluded that the DSR was very effective for the introduction of a uniform microstructure throughout the thickness of the copper alloy.

Light-emitting property of the EL device with the thickness ratio of the HTL.ETL (HTL/ETL 두께 비율에 따른 EL 소자의 발광 특성)

  • 손철호;여철호;박정일;장선주;박종화;이영종;정홍배
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.170-173
    • /
    • 2000
  • In this study, we have investigated the light-emitting property of the EL device with the thickness ratio of the HTL/ETL, which was 500$\AA$:500$\AA$, 400$\AA$:600$\AA$, 600$\AA$:400$\AA$. The ALq$_3$ was used for the ETL. We have studied the relation of voltage, contrase, efficiency for current density. Emission was observed above 10mA/$\textrm{cm}^2$ and luminance was measured to be 1030cd/$m^2$ at a current density of 100mA/$\textrm{cm}^2$ in 500$\AA$/500$\AA$ sample. A luminance of over 2500cd/$m^2$ was also observed after the final fabrication process in 500$\AA$/500$\AA$ sample

  • PDF

Study on the Water-Vapor Permeation through the Al Layer on Polymer Substrate (폴리머 기판에 형성한 알루미늄 보호막의 수분침투 특성 연구)

  • Choi, Young-Jun;Ha, Sang-Hoon;Park, Ki-Jung;Choe, Youngsun;Cho, Young-Rae
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.12
    • /
    • pp.873-880
    • /
    • 2009
  • Water-vapor permeation through metallic barriers deposited on polymer substrates has been an important technological issue because the performance of the barrier is critical to the reliability of flexible organic devices. For the development of long-lifetime flexible organic devices, two different sets of samples were designed and demonstrated from the viewpoint of the water-vapor transmission rate (WVTR). Aluminum (Al) and polyethylene terephthalate (PET) were chosen for the barrier layer and the polymer substrate, respectively. Two stacking structures, a single-layer (Al/PET) structure and a double-layer (Al/PET/Al) structure, were used for the WVTR measurement. For the single-layer structure, the WVTR decreases as the thickness of the barrier layer increases. Compared to the single-layer sample, the double-layer sample showed superior WVTR performance (by nearly three times) when the total thickness of the Al barrier was greater than 100 nm.