• 제목/요약/키워드: Sample matrix

검색결과 697건 처리시간 0.027초

구배행렬법에 의한 복소 유전율 및 투자율의 결정 (Determination of Complex Permittivity and Permeability by a Gradient Matrix Method)

  • 전중창;박위상
    • 전자공학회논문지A
    • /
    • 제29A권11호
    • /
    • pp.14-18
    • /
    • 1992
  • A gradient matrix method in conjunction with the transmission-reflection method to determine the complex permittivity and permeability of a microwave material is presented. This method does not incur the phase ambiguity due to an improper sample length, and is applicable to the measurement of low-loss materials of a half wavelength. A gradient matrix for a coaxial cable sample is derived, and the results are illustrated.

  • PDF

나노물질을 이용한 질량분석 기술 개발동향 (Mass spectrometry based on nanomaterials)

  • 박종민;노주윤;김문주;변재철
    • 세라미스트
    • /
    • 제21권3호
    • /
    • pp.249-269
    • /
    • 2018
  • In conventional MALDI-TOF mass spectrometry, analyte molecules are known to be ionized by mixing with organic matrix molecules. As the organic matrix molecules are made into small fragments, they generate unreproducible mass peaks such that MALDI-TOF mass spectrometry is nearly impossible in the low mass-to-charge (m/z) range (< 1000). Additionally, the dried sample mixed with matrix were made as inhomogeneous crystal on metal plate. When the laser radiation was made on the sample crystal, the amount of generated sample ion was observed to be quite different according to the radiation point. Therefore, the quantitative analysis was very difficult even for the sample spots at the same concentration for the conventional MALDI-TOF mass spectrometry. In this work, we present laser desorption/ionization (LDI) mass spectrometry based on solid-matrices for the quantitative analysis of small molecules in the low m/z range by using MALDI-TOF mass spectrometry: (1) Carbon based nanostructures; (2) Semiconductor based nanomaterials; (3) Metal based nanostructures.

Numerical and statistical analysis of permeability of concrete as a random heterogeneous composite

  • Zhou, Chunsheng;Li, Kefei
    • Computers and Concrete
    • /
    • 제7권5호
    • /
    • pp.469-482
    • /
    • 2010
  • This paper investigates the concrete permeability through a numerical and statistical approach. Concrete is considered as a random heterogeneous composite of three phases: aggregates, interfacial transition zones (ITZ) and matrix. The paper begins with some classical bound and estimate theories applied to concrete permeability and the influence of ITZ on these bound and estimate values is discussed. Numerical samples for permeability analysis are established through random aggregate structure (RAS) scheme, each numerical sample containing randomly distributed aggregates coated with ITZ and dispersed in a homogeneous matrix. The volumetric fraction of aggregates is fixed and the size distribution of aggregates observes Fuller's curve. Then finite element method is used to solve the steady permeation problem on 2D numerical samples and the overall permeability is deduced from flux-pressure relation. The impact of ITZ on overall permeability is analyzed in terms of ITZ width and contrast ratio between ITZ and matrix permeabilities. Hereafter, 3680 samples are generated for 23 sample sizes and 4 contrast ratios, and statistical analysis is performed on the permeability dispersion in terms of sample size and ITZ characteristics. By sample theory, the size of representative volume element (RVE) for permeability is then quantified considering sample realization number and expected error. Concluding remarks are provided for the impact of ITZ on concrete permeability and its statistical characteristics.

Determination of Boron Steel by Isotope-Dilution Inductively Coupled Plasma Mass Spectrometry after Matrix Separation

  • Park, Chang-J.
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권11호
    • /
    • pp.1541-1544
    • /
    • 2002
  • The concentration of B in steels is important due to its influence on mechanical properties of steel such as hardenability, hot workability, and creep resistance. An analytical method has been developed to determine B in steel samples by high-resolution inductively coupled plasma mass spectrometry (HR-ICP-MS). National Institute of Standard and Technology Standard Reference Material (NIST SRM) 348a was analyzed to validate the analytical method. The steel sample was digested in a centrifuge bottle with addition of aqua regia and $^{10}B$ spike isotope. Sample pH was then adjusted to higher than 10 to precipitate most matrix elements such as Fe, Cr, and Ni. After centrifugation, the supernatant solution was passed through a cation exchange column to enhance the matrix separation efficiency. B recovery efficiency was about 37%, while matrix removal efficiency was higher than 99.9% for major matrix elements. The isotope dilution method was used for quantification and the determined B concentration was in good agreement with the certified value.

불활성기체용해-열전도도검출법에 의한 수소분석시 티타늄 및 지르코늄-2.5니오븀 시료의 매질효과 (Matrix effect of Ti and Zr-2.5Nb sample for hydrogen analysis by Inert Gas Fusion-Thermal Conductivity Detection(IGF-TCD) Method)

  • 박순달;최계천;김정석;조기수;김종구;김원호
    • 분석과학
    • /
    • 제16권4호
    • /
    • pp.261-268
    • /
    • 2003
  • 불활성기체용해-열전도도검출법에 의한 수소분석시 매질효과를 조사하기 위해 티타늄 및 지르코늄-2.5니오븀 매질의 수소 표준물질 및 수소기체 주입에 의한 교정계수를 측정하였다. 또한 주석 조연제를 사용하지 않고 티타늄 및 지르코늄-2.5니오븀 매질 수소 표준물질의 수소 추출효율을 조사하였다. 수소기체 주입에 의한 수소분석기의 보정에 대해 지르코늄-2.5니오븀 매질 수소표준물질의 그것은 2~3% 높았으며, 티타늄 매질의 수소 표준물질은 약 14% 높은 값을 주었다. 교정계수 측정결과에 의하면 티타늄 매질 시료의 수소추출 효율이 지르코늄-2.5니오븀 매질 시료에 비해 약 12% 낮을 것으로 예상된다. 주석을 사용하지 않았을 때 티타늄 및 지르코늄-2.5니오븀매질 수소 표준물질의 수소 회수율은 약 70% 이었으며, 티타늄의 수소 회수율이 지르코늄-2.5니오븀 보다 낮았다.

Efficiency of Gas-Phase Ion Formation in Matrix-Assisted Laser Desorption Ionization with 2,5-Dihydroxybenzoic Acid as Matrix

  • Park, Kyung Man;Ahn, Sung Hee;Bae, Yong Jin;Kim, Myung Soo
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권3호
    • /
    • pp.907-911
    • /
    • 2013
  • Numbers of matrix- and analyte-derived ions and their sum in matrix-assisted laser desorption ionization (MALDI) of a peptide were measured using 2,5-dihydroxybenzoic acid (DHB) as matrix. As for MALDI with ${\alpha}$-cyano-4-hydroxy cinnamic acid as matrix, the sum was independent of the peptide concentration in the solid sample, or was the same as that of pure DHB. This suggested that the matrix ion was the primary ion and that the peptide ion was generated by matrix-to-peptide proton transfer. Experimental ionization efficiencies of $10^{-5}-10^{-4}$ for peptides and $10^{-8}-10^{-7}$ for matrices are far smaller than $10^{-3}-10^{-1}$ for peptides and $10^{-5}-10^{-3}$ for matrices speculated by Hillenkamp and Karas. Number of gas-phase ions generated by MALDI was unaffected by laser wavelength or pulse energy. This suggests that the main role of photo-absorption in MALDI is not in generating ions via a multi-photon process but in ablating materials in a solid sample to the gas phase.

MUSIC을 근간으로 하는 고해상도 DOA 방법의 성능분석에 관한 연구 (A Study on Performance Analysis of High Resolution DOA Method based on MUSIC)

  • 이일근;최인경;김영집;강철신
    • 한국통신학회논문지
    • /
    • 제19권2호
    • /
    • pp.345-353
    • /
    • 1994
  • 본 논문에서는 Sample Array Covariance Matrix의 대각선요소들의 평균치를 취하여 이를 대각선 요소값들로 대치하여 도래방향각 예측을 수행하는 소위 'Averaged MUSIC' 방법이 낮은 신호대잡음비, 신호원들이 근접해 있는 경우, Sensor의 수가 제한되어 있는 경우등에서 MUSIC에 비하여 훨씬 고해상도의 DOA 예측을 수행함을 보였다. 이를 위해서 통계적인 방법을 사용하여서 한 두가지 경우에 나오는 특별한 결과를 배제하고 가능한한 정확한 결과 비교를 위해 노력하였다.

  • PDF

Estimators Shrinking towards Projection Vector for Multivariate Normal Mean Vector under the Norm with a Known Interval

  • Baek, Hoh Yoo
    • 통합자연과학논문집
    • /
    • 제11권3호
    • /
    • pp.154-160
    • /
    • 2018
  • Consider the problem of estimating a $p{\times}1$ mean vector ${\theta}(p-r{\geq}3)$, r = rank(K) with a projection matrix K under the quadratic loss, based on a sample $Y_1$, $Y_2$, ${\cdots}$, $Y_n$. In this paper a James-Stein type estimator with shrinkage form is given when it's variance distribution is specified and when the norm ${\parallel}{\theta}-K{\theta}{\parallel}$ is constrain, where K is an idempotent and symmetric matrix and rank(K) = r. It is characterized a minimal complete class of James-Stein type estimators in this case. And the subclass of James-Stein type estimators that dominate the sample mean is derived.

치과 임플란트용 bioactive 세라믹 복합재료의 제조와 미세조직 (Microstructure and Processing of Bioactive Ceramic Composites as Dental Implants)

  • 김부섭
    • 대한치과기공학회지
    • /
    • 제25권1호
    • /
    • pp.21-28
    • /
    • 2003
  • The purpose of this study was to process bio-active glass ceramic composite, reinforced with sapphire fibers, by hot press. Also to study the interface of the matrix and the sapphire fiber, and the mechanical properties. Glass raw materials melted in Pt crucible at 1300$^{\circ}C$ during 3.5 hours. The melt was crushed in ball mill and then crushed material, ground and sieved to $<40{\beta}{\mu}m$. Sapphire fibers cut (30mm) and aligned. Powder and fibers hot pressed. The micrographs show good bonding between the matrix and the fiber and no porosity in the glass matrix. This means ideal fracture phenomena. Glass is fractured before the fiber. This is indication of good fracture strength. EDXS showing aluminum rich phase and crystalline phase. Bright field image of the matrix showing crystalline phase. Also diffraction pattern of TEM showing the crystalline phase and more than one phase. Strength of the samples was determined by 3 point bend testing. Strength of the 10vol% sample was approximately 69MPa, while strength of the control sample is 35MPa. Conclusions through this study as follow: 1. Micrographs show no porosity in the glass matrix and the interface. 2. The interface between the fiber and the glass matrix show no gaps. 3. Fracture of the glass indicates characteristic fiber-matrix separation. 4. Presence of crystalline phase at high processing temperature. 5. Sapphire is compatible with bioactive glass.

  • PDF

Empirical Analysis on Rao-Scott First Order Adjustment for Two Population Homogeneity test Based on Stratified Three-Stage Cluster Sampling with PPS

  • Heo, Sunyeong
    • 통합자연과학논문집
    • /
    • 제7권3호
    • /
    • pp.208-213
    • /
    • 2014
  • National-wide and/or large scale sample surveys generally use complex sample design. Traditional Pearson chi-square test is not appropriate for the categorical complex sample data. Rao-Scott suggested an adjustment method for Pearson chi-square test, which uses the average of eigenvalues of design matrix of cell probabilities. This study is to compare the efficiency of Rao-Scott first order adjusted test to Wald test for homogeneity between two populations using 2009 Gyeongnam regional education offices's customer satisfaction survey (2009 GREOCSS) data. The 2009 GREOCSS data were collected based on stratified three-stage cluster sampling with probability proportional to size. The empirical results show that the Rao-Scott adjusted test statistic using only the variances of cell probabilities is very close to the Wald test statistic, which uses the covariance matrix of cell probabilities, under the 2009 GREOCSS data based. However it is necessary to be cautious to use the Rao-Scott first order adjusted test statistic in the place of Wald test because its efficiency is decreasing as the relative variance of eigenvalues of the design matrix of cell probabilities is increasing, specially more when the number of degrees of freedom is small.