• Title/Summary/Keyword: Same reference point method

Search Result 60, Processing Time 0.023 seconds

Design of Parallel Decimal Floating-Point Arithmetic Unit for High-speed Operations (고속 연산을 위한 병렬 구조의 십진 부동소수점 연산 장치 설계)

  • Yun, Hyoung-Kie;Moon, Dai-Tchul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.12
    • /
    • pp.2921-2926
    • /
    • 2013
  • In this paper, a decimal floating-point arithmetic unit(DFP) was proposed and redesigned to support high speed arithmetic operation employed parallel processing technique. The basic architecture of the proposed DFP was based on the L.K.Wang's DFP and improved it enabling high speed operation by parallel processing for two operands with same size of exponent. The proposed DFP was synthesized as a target device of xc2vp30-7ff896 using Xilinx ISE and verified by simulation using Flowrian tool of System Centroid co. Compared to L.K.Wang's DFP and reference [6]'s method, the proposed DFP improved data processing speed about 8.4% and 3% respectively in case of same input data.

Diagnostic Potential of Strain Ratio Measurement and a 5 Point Scoring Method for Detection of Breast Cancer: Chinese Experience

  • Parajuly, Shyam Sundar;Lan, Peng Yu;Yun, Ma Bu;Gang, Yang Zhi;Hua, Zhuang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.4
    • /
    • pp.1447-1452
    • /
    • 2012
  • Aim: To evaluate the differential diagnostic potential of lesion stiffness assessed by the sonoelastographic strain index ratio (SR) and elastographic color scoring system (UE) for breast lesions. Materials and Methods: Three hundred and forty two breast masses (158 benign and 184 malignant) from 325 consecutive patients (mean age 44.2 years; range 16-81)who had been scheduled for a sonographically guided core biopsy were examined proposed by Itoh et al, with scoring 1-3=benign and 4-5=malignant. Strain and area ratios of each lesion were calculated within the same machine. Histological diagnosis was used as the reference standard. The area under the curve (AUC) and cut-off point were obtained by receiver operating curve and the cross table Fischer Test was carried out for assessing diagnostic value. Sensitivity, specificity, PPV, NPV, accuracy and false-discovery rates were compared. Results: The mean strain ratios for benign and malignant lesions were 1.87 and 7.9 respectively. (P<0.0001). When a cutoff point of 3.54 was used, SR had a sensitivity of 94.6%, a specificity 94.3%, a PPV of 95.1%, an NPV of 93.7% and an accuracy of 94.4%. The AUC values were 0.90 for the 5 point scoring system (UE) and 0.96 for the strain index ratio. The overall diagnostic performance was SR method was better (P<0.05). Conclusions: Strain ratio measurement could be another effective predictor in elastography imaging besides 5 the point scoring system for differential diagnosis of breast lesions.

A Study on Designing an Effective Support Point for After-Stern Tube Bearings Concerning Shaft Alignment (추진축계 정렬시 선미관 베어링 유효지지점 설정에 관한 연구)

  • Lee, Jae-ung;Kim, Yeonwon;Kim, Jung-Ryul
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.6
    • /
    • pp.803-809
    • /
    • 2018
  • Generally, the gap-and-sag method is used in the shipbuilding stage before coupling the shafts to check whether they are installed at the same position as designed and derived from shaft alignment calculation. The primary installed propeller shaft becomes a reference point, the position of the remaining shafts are sequentially determined through the gap-and-sag value derived from the deflection and deflection angle at each shaft flange by own weight. If the reference point varies against the design value, it would have a series of effects on the installation of the remaining shafts. Moreover, after coupling the shafts, even if the bearing reaction forces derived from measurement are satisfied by the allowable limit range, consequently it might have an adverse effect on the stability of the shafting system by not being able to estimate the relative slope angle between the propeller shaft and the after-stern tube bearing. In this paper, to deal with above-mentioned phenomenon, the theoretical calculations related to designing an effective support point of the aft stern tube bearing and analysis by measurement is conducted through a case of open-up inspections. Based on this, a shaft installation guideline is proposed to minimize the misalignment related to preventing wiping damage of the after-stern tube bearing.

Characteristics Analysis of RPV and AFD for Anti-Islanding in Active Method (단독운전방지를 위한 능동 방식 중 AFD 및 RPV에 대한 특성해석)

  • Choe, Gyu-Ha;D, Bayasgalan;Lee, Young-Jin;Han, Dong-Ha;Jeong, Byong-Hwan;Kim, Hong-Sung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.160-167
    • /
    • 2009
  • To detect islanding mode when the grid is being tripped is a major safety issue in the Utility Interactive Photo Voltaic (UIPV) system. In this paper, analytical design method is suggested for AFD & RPV method under IEEE 929-2000 recommended islanding test condition. We have discussed that there is a same point. we injected reactive component of the current by AFD & RPV methods, but the current reference generated is other waveform. Possible if amount of reactive components in this methods are same each method, there is happened same rates frequency variation. To verify the validity of the analytical comparison, this paper presents simulation and experimental results from single phase, 3[kW] inverter for the transformerless UIPV system.

A Study for the Appropriateness of the Different Reference Points in the Analysis of Working Posture

  • Kim, Day-Sung;Kim, Chol-Hong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.5
    • /
    • pp.637-644
    • /
    • 2011
  • Objective & Background: When applying various evaluation tools that analyze work posture risk through observation, accurate measurement of body flexion angle is very important. Method: This study investigated differences and appropriateness of 5 different existing reference points commonly used in the analysis of the work posture. Twenty five ergonomist and trained professionals were participated in this study. A Same flexion angle was utilized for the evaluation of risk assessment of musculoskeletal disorders using five different reference points to investigate the degree of difference between them. To investigate how different the observers' preferred flexion angle measuring methods were compared to the ISO 11226 Reference Posture, a virtual body model was constructed using the Poser 6.0 program. Six types of body flexion postures were constructed, and since neck flexion differs according to body angle, five types of neck flexion postures were constructed with the trunk bending $20^{\circ}$ forward, making up a total of 30 virtual flexion postures. Results: Results showed that the observers used personally preferred reference points instead of reference points recommend in the evaluation tools. Also the results revealed the their seems to be 6 types of flexion angle for the trunk and 11 types of measurement methods for the neck flexion angle in the form of personally preferred reference points. The results showed that a mean difference of $14^{\circ}$($4{\sim}23^{\circ}$) occurred in the trunk, and a mean difference of $20^{\circ}$($-8{\sim}51^{\circ}$) occurred in the neck. To increase accuracy when using the 5 evaluation tools in combination, the ISO 11226 standards, observers' preferred flexion posture standards, and common flexion posture standards of the evaluation tools were compared with the reference points of the 5 evaluation tools. Results showed considerable variance in angle difference for each evaluation tool. Conclusion: According to the results of this study, considering the angle difference between the flexion angle reference points of the evaluation tool and the reference points selected by the observers, it is concluded that instead of personally preferred reference points, the standardized reference points to enhance the accuracy and the objectivity. Application: The result of this study can be used as reference guide to develop the standardized reference point in the future.

Structural integrity assessment procedure of PCSG unit block using homogenization method

  • Gyogeun Youn;Wanjae Jang;Youngjae Jeon;Kang-Heon Lee;Gyu Mahn Lee;Jae-Seon Lee;Seongmin Chang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1365-1381
    • /
    • 2023
  • In this paper, a procedure for evaluating the structural integrity of the PCSG (Printed Circuit Steam Generator) unit block is presented with a simplified FE (finite element) analysis technique by applying the homogenization method. The homogenization method converts an inhomogeneous elastic body into a homogeneous elastic body with same mechanical behaviour. This method is effective when the inhomogeneous elastic body has repetitive microstructures, and thus the method was applied to the sheet assembly among the PCSG unit block components. From the method, the homogenized equivalent elastic constants of the sheet assembly were derived. The validity of the determined material properties was verified by comparing the mechanical behaviour with the reference model. Thermo-mechanical analysis was then performed to evaluate the structural integrity of the PCSG unit block, and it was found that the contact region between the steam header and the sheet assembly is a critical point where large bending stress occurs due to the temperature difference.

Image Segmentation based on Statistics of Sequential Frame Imagery of a Static Scene (정지장면의 연속 프레임 영상 간 통계에 기반한 영상분할)

  • Seo, Su-Young;Ko, In-Chul
    • Spatial Information Research
    • /
    • v.18 no.3
    • /
    • pp.73-83
    • /
    • 2010
  • This study presents a method to segment an image, employing the statistics observed at each pixel location across sequential frame images. In the acquisition and analysis of spatial information, utilization of digital image processing technique has very important implications. Various image segmentation techniques have been presented to distinguish the area of digital images. In this study, based on the analysis of the spectroscopic characteristics of sequential frame images that had been previously researched, an image segmentation method was proposed by using the randomness occurring among a sequence of frame images for a same scene. First of all, we computed the mean and standard deviation values at each pixel and found reliable pixels to determine seed points using their standard deviation value. For segmenting an image into individual regions, we conducted region growing based on a T-test between reference and candidate sample sets. A comparative analysis was conducted to assure the performance of the proposed method with reference to a previous method. From a set of experimental results, it is confirmed that the proposed method using a sequence of frame images segments a scene better than a method using a single frame image.

Development of Distortion Correction Technique in Tilted Image for River Surface Velocity Measurement (하천 표면영상유속 측정을 위한 경사영상 왜곡 보정 기술 개발)

  • Kim, Hee Joung;Lee, Jun Hyeong;Yoon, Byung Man;Kim, Seo Jun
    • Ecology and Resilient Infrastructure
    • /
    • v.8 no.2
    • /
    • pp.88-96
    • /
    • 2021
  • In surface image velocimetry, a wide area of a river is photographed at an angle to measure its velocity, inevitably causing image distortion. Although a distorted image can be corrected into an orthogonal image by using 2D projective coordinate transformation and considering reference points on the same plane as the water surface, this method is limited by the uncertainty of changes in the water level in the event of a flood. Therefore, in this study, we developed a tilt image correction technique that corrects distortions in oblique images without resetting the reference points while coping with changes in the water level using the geometric relationship between the coordinates of the reference points set at a high position the camera, and the vertical distance between the water surface and the camera. Furthermore, we developed a distortion correction method to verify the corrected image, wherein we conducted a full-scale river experiment to verify the reference point transformation equation and measure the surface velocity. Based on the verification results, the proposed tilt image correction method was found to be over 97% accurate, whereas the experiment result of the surface velocity differed by approximately 4% as compared to the results calculated using the proposed method, thereby indicating high accuracy. Application of the proposed method to an image-based fixed automatic discharge measurement system can improve the accuracy of discharge measurement in the event of a flood when the water level changes rapidly.

Evaluation of Marginal and Internal Gap of Temporary Prosthesis Fabricated by 3D Printing Method According to Rinsing Method and Rinsing Time (세척 방법 및 세척 시간에 따른 3D 프린팅 방식으로 제작된 임시 보철물의 변연 및 내면 적합도 평가)

  • Ji-Hyeon Bae;Jae-Won Choi
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.4_2
    • /
    • pp.561-570
    • /
    • 2023
  • This study was to evaluate the effect of different rinsing times and methods on the accuracy of temporary prostheses fabricated by 3D printing method. Sixty temporary prostheses were fabricated with LCD types of 3D printer(Halot-Sky, Creality, Shenzhen, China) and divided into six groups (n = 10) based on rinsing times and methods. All specimens were rinsed with 99% isopropanol alcohol for 5 and 10 min using three methods-hand washed, ultrasonic cleaning, and automated washing. All specimens were polymerized for 3 minutes under the same conditions. The marginal and internal gaps of specimens were examined using a replica technique. The light-body silicone thickness was measured at 6 reference points(Absolute marginal discrepancy, Marginal, Chamfer, Axial, Angle, and Occlusal gap). All measurements were performed by a stereomicroscope. Reference point images were taken at 100× magnification and then measured using an image analysis program. Statistical analysis was performed using Two-way ANOVA, One-way ANOVA, and the Kruskal-Wallis test (p = .05). The marginal and internal gaps were statistically different according to the rinsing methods and rinsing times(p < .001). In the rinsing time, the temporary prosthesis rinsed for 5 minutes group showed higher accuracy than 10 minutes group. In the rinsing method, the hand washing group showed higher accuracy than the automated washing group.

MMAD Computation for Fast Diamond-Search Algorithm (고속 다이아몬드 탐색 알고리즘을 위한 MMAD 연산법)

  • 서은주;김동우;한재혁;안재형
    • Journal of Korea Multimedia Society
    • /
    • v.4 no.5
    • /
    • pp.406-413
    • /
    • 2001
  • Ordinary high-speed block matching algorithms have a disadvantage that they need to get MAD (Mean Absolute Distance) as many as the number of search points due to comparing the MAD between the current frame's search block and the reference frame's search block. To solve such disadvantage of high-speed block matching algorithm, the proposed high-speed DS algorithm employs a MMAD calculation method using a specific characteristic that neighboring pixels have almost same values. In this thesis, we can get rid of unnecessary MAD calculation between the search point block by the new calculation method which uses the previously calculated MAD as the current search point and by breaking from the established MAD calculation method which calculates the MAD of a new search point by each search stage. Comparing with the established high-speed block matching algorithm, this new calculation's estimated movement error was shown as similar, and th total calculation amount decreased by $2FN^2Ep$.

  • PDF