• Title/Summary/Keyword: Salinity Measurement

Search Result 70, Processing Time 0.02 seconds

Salinity Determination Using Temperature Compensated On-Line Refractometer (온도보상형 온라인 굴절계를 이용한 해수의 염도 측정)

  • 최한욱;김영한
    • Journal of Korean Port Research
    • /
    • v.15 no.1
    • /
    • pp.99-105
    • /
    • 2001
  • An on-line refractrometer made of easily obtainable materials is built to determine the salinity and temperature of sea water, and its performance is examined by applying the refractometer to known salt solution. Since refractive index and temperature are measured simultaneously, it is possible to compensate the effect of temperature for accurate measurement. The outcome of salinity measurement for the different concentrations of salt solution indicates that the device is suitable for the salinity measurement by yielding stable and reproducible reading.

  • PDF

Salinity Determination for Sea Water Using Immersion-Type On-Line Refractometer (침적식 온라인 굴절계를 이용한 해수의 염도 측정)

  • Kim, Byoung-Chul;Kim, Young-Han;Chan, Sang-Mok
    • Journal of Navigation and Port Research
    • /
    • v.26 no.5
    • /
    • pp.571-575
    • /
    • 2002
  • An immersion-type on-line refractometer useful for the in-situ measurement of salinity and temperature of sea water is developed, and its performance is examined by applying the refractometer to known salt solution having salt concentration between 2 and 4 % similar to practical sea water salinity. Since refractive index and temperature are measured simultaneously, it is possible to compensate the effect of temperature for fast and direct measurement. The outcome of salinity measurement for the different concentrations of salt solution indicates that the device is suitable for the salinity measurement by yielding stable and reproducible reading.

Salinity and water level measuring device using fixed type buoyancy (고정식 부력을 이용한 염도 및 수위 측정 방식에 대한 연구)

  • Yang, Seung-Young;Byun, Kyung-Seok
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.1
    • /
    • pp.1-6
    • /
    • 2020
  • To make an automated system for a salt field, it is necessary to measure the salinity and water level of the evaporation site. In this paper, a method to simultaneously measure the salinity and water level by measuring the buoyancy forces of two fixed buoyancy bodies is proposed. The proposed measurement method measures the buoyancy of the main part and reference part when the measuring device is immersed in the salty water, and simultaneously measures the salinity and water level through the sum and difference of the two buoyancy forces. Since there is no mechanical movement in the measurement of buoyancy, measurement errors and maintenance needs can be reduced in the mudy environment of salt field. By applying the proposed method, we developed a system that can simultaneously measure salinity and water level remotely at the evaporation site of a salt field. Through a measurement experiment using a reference salty water having various levels of salinity, the results of a salinity error of 0% and a water level error of 2mm were obtained, and the effectiveness of the proposed salinity and water level measuring device was verified. When an automated system is constructed using the developed salinity and water level measuring device, labor reduction, work environment improvement, and productivity improvement are expected.

A Consideration on the Effect of the Fine Content and Salinity of Soils on the TDR Measurement (토양의 세립분 함량과 염분농도가 TDR 측정값에 미치는 영향 고찰)

  • Yu, Chan;Lee, Geun-Hu
    • KCID journal
    • /
    • v.13 no.2
    • /
    • pp.246-253
    • /
    • 2006
  • Experimental laboratory tests were carried out to assess the effect of fine content and salinity of soils on the measurement of TDR(Time Domain Reflectometry). In the test, using soil columm which was made by PVC pipe with the dimension of 25cm height and 20cm diameter, the salinity variation of soil was controlled by the solution which was dissolved NaCl to destilled water in the range of 0-40g.$L^-1$. The fine content of soil was controlled by kaolinite which was mixed with Jumunjin sand in the range of 0-50% to the total dry weight. The water contents of soil tested were measured with the conventional oven dry method beside TDR and compared the these values to figure out the extent of effect. As the results of tests, it was appeared that the water content measurement by TDR can be affected by the salinity level, fine contents, and the degree of saturation of the soil.

  • PDF

Comparison of Salinity and Sodium Content by the Salinity Measurement Frequency of Soups of Childcare Centers Enrolled in the Center for Children's Food Service Management in Daegu (대구지역 어린이급식관리지원센터 등록 어린이급식소의 염도 측정 빈도에 따른 국의 염도 및 나트륨 함량 비교)

  • Lee, Na-Yeong;Lee, Yeon-Kyung
    • Korean Journal of Community Nutrition
    • /
    • v.25 no.1
    • /
    • pp.13-20
    • /
    • 2020
  • Objectives: This study examined the salinity of soups provided at childcare centers by measuring the salinity for three years and providing basic data for sodium reduction. Methods: The soup salinity was measured using a Bluetooth salinity meter from January 2015 to December 2017 at 80 childcare foodservice establishments enrolled in the Suseong Center for Children's Foodservice Management in Daegu. Results: An analysis of the soup salinity each year showed that the salinity decreased significantly from 0.48% in 2015 to 0.41% in 2017, particularly in clear soups and soybean soups compared to other soups (P < 0.05). The salinity and sodium content in seafood soups (0.45% and 179.1 mg/100 g, respectively) were highest, followed by soybean soups (0.44%, 175.2 mg/100 g), with perilla seed soups containing the lowest (0.42%, 167.2 mg/100 g) (P < 0.05). The salinity was significantly higher in institutional foodservice establishments than small foodservice establishments (P < 0.001). The salinity and sodium content were the highest in foodservice establishments with a small number of measurements, and the salinity was the lowest in foodservice establishments with salinity measurements performed an average of 151 times each year (three times a week) or more (P < 0.05). The soup salinity was low in the order of winter, spring, summer, and autumn, and the salinity decreased significantly year by year in all seasons. (P < 0.05). Conclusions: The soup salinity was significantly lower in foodservice establishments where the salinity was measured more than three times a week, indicating that continuous salinity management is effective.

Analyses of Salinity Unit in the Secondary School Science Textbook and Suggestion for Its Correction (중등 과학교과서에서 사용된 염분 단위 분석 및 단위 개정을 위한 제안)

  • Park, Kyung-Ae;Choi, Ji-Young
    • Journal of the Korean earth science society
    • /
    • v.30 no.4
    • /
    • pp.513-526
    • /
    • 2009
  • It has long been that the unit of oceanic salinity changed from permil (%o) to other unit. However, the middle-and high- school textbooks of science and earth science have still used %o as salinity unit that was defined a long time ago. The objectives of this study are to briefly discuss about the historical development of change in salinity unit and measurement techniques, to present differences between the salinity units of psu (practical salinity unit) and %o, and to address the need and validity for the correction of salinity unit in the textbooks. Twenty-seven kinds of textbooks based on the 7th National Curriculum were analyzed to investigate the expression of salinity unit and the definition of salinity. The results were compared with the usage of salinity units in the articles published in Journal of Korean Society of Oceanography from 1967 to 2008. The percentages by the use of %o were 96.3% in the text and 83.8% in the graphs or tables of the textbooks. By contrast, the scientific papers began to use psu from 1994 and then %o has seldom been used since 2004.

Characteristics on the distribution of salinity of airborne sea salt by height (높이에 따른 비래염분량의 감소 특성)

  • Lee Jong Suk;Choi Won Sung;Kim Do Gyeum;Moon Han Young
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.261-264
    • /
    • 2005
  • For concrete structures immersed in seawater, the concentration of chloride used to estimate the chloride diffusion coefficient can be defined as the seawater chloride concentration. However, for seashore concrete structures which are not coming into direct contact with seawater, establishing the interface concentration of chloride becomes delicate. In addition, concrete structures are greatly affected by salt attack primarily due to airborne sea salt like it can be seen through the corrosion of rebar. This study intends to investigate characteristics on the salinity of airborne sea salt by height. Salinity measurement devices were installed at height of 2, 10 and 19m on the seashore water tower located in the area of Samchuk in the Eastern coast. Analysis results of the decrease of salinity with respect to the height above the ground at a distance of 30m from the seashore showed that the reduction reached about 40$\%$ at a height of 10m and 60$\%$ at 20m.

  • PDF

Short-term behavioral responses and tolerance limits of red seabream Pagrus major fingerlings following sudden low salinity exposure (급격한 저염분 노출에 따른 참돔 Pagrus major 치어의 단기 행동반응 및 내성 한계에 관한 연구)

  • Sung Jin Yoon
    • Korean Journal of Environmental Biology
    • /
    • v.39 no.4
    • /
    • pp.495-506
    • /
    • 2021
  • In this study, using a continuous behavior measurement technique, the short-term behavioral responses and tolerance limits of red seabream Pagrus major fingerlings to sudden exposure to low salinity in a controlled environment were observed. The activity of the fingerlings suddenly exposed to 21.4, 17.3, and 9.8 psu increased temporarily at the initial exposure to show irregular swimming behavior, but then recovered a stable activity pattern through rapid salinity adaptation. However, the organisms suddenly exposed to 7.3 and 4.3 psu could not withstand the salinity stress, and their swimming behavior was severely disturbed and all individuals died within 48 hours. The findings suggest that red seabream underwent a temporary salinity stress process at the beginning of the exposure to concentrations of 10.0 psu or higher. At these concentrations, osmotic control was possible within at least 11 hours, so stable metabolic activity was also possible. However, organisms suddenly exposed to concentrations below 5.0 psu exceeded the tolerance to low salinity and the sublethal limit. In red seabream exposed to this concentration range, severe behavioral and metabolic disturbances were observed, and death was observed due to osmotic control failure. In conclusion, a salinity range of 5.0 to 10.0 psu can be predicted to correspond to a concentration range in which the osmotic control ability of the red seabream fingerlings is lost, and sub-lethal reactions occur.

An Experiment for determining Electrical Conductivity in Modelholes using Continuous Measurement System (공내수 전기전도도의 자동측정시스템 구축을 위한 실험)

  • 김영화;박정빈;임헌태
    • The Journal of Engineering Geology
    • /
    • v.13 no.3
    • /
    • pp.281-292
    • /
    • 2003
  • We setup a continuous measurement system for electrical conductivity of fluid in a model borehole and verified the basic environments in electrical conductivity measurement for estimating hydraulic constants. The experiment was made by monitoring the conductivity change within the hole using NaCI solution of different salinities and incoming formation fluid using distilled water. The experiment was made under the state of constant flow rate by maintaining balance between inflow and outflow. Conductivity variation features were observed by controlling salinity contrasts and temperature differences between fluid within the hole and incoming formation fluid. flow rate and the location of inlet and outlet. The results of the experiment show well the role of each affecting factor on the conductivity distribution. and suggest appropriate environments for conductivity measurements. It is considered that the basis of the conductivity measurement for henceforward laboratory model and/or in-situ borehole experiment has been prepared.