A Study on Calculation of Recycling Standard Cost for Efficient Operation of EPR (효율적인 EPR 운영을 위한 재활용 기준비용 산정에 관한 연구)

  • Lee, Hee-Nahm;Choi, Yoon-Jeong
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.1
    • /
    • pp.121-126
    • /
    • 2011
  • The provisions regarding the standard cost for recycling stated under the Extended Producer Responsibility (EPR) since 2002, include different and complicated obligatory steps to be taken on a variety of subject items regarding the collection, the transportation and the treatment, making the corporations face in their calculating and executing the standard cost. This study presents more objective calculation scope and standard for the purpose of efficient operation of the standard cost for recycling, in consideration of the general industry perception toward cost issue as well as domestic/overseas case studies regarding the standard cost for recycling. Besides, the study presents the checking items and the calculation contents per step to calculate the standard cost for recycling. Therefore, it is expected not only to be used as the objective standard to calculate the standard cost for recycling, but also to contribute to increasing the work efficiency in the following ongoing re-calculation process and to maintaining the consistent operation of the institution.

Proposed Revision of Standard on Articles for Forklift Trucks in Manufacturing Industries (제조업에서 지게차에 대한 안전보건 기준에 관한 규칙 개정 방안)

  • Shin, Woonchul;Rhee, Hongsuk;Park, Jai Hak
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.4
    • /
    • pp.33-37
    • /
    • 2013
  • A forklift truck, commonly used for transporting heavy materials in manufacturing industries, etc., is a useful machine. However accidents occur frequently during the operation of the machine. In order to prevent accidents it is necessary to examine the current safety regulations on a forklift truck. Because the regulations have not revised for a long time, they do not reflect the rapidly changing environment of industries. Proposed revision of standard on articles for forklift trucks was presented after analysing the causes of occurred injuries, comparing domestic standards with international standards and examining the survey results. We analyzed the safety regulation articles and the injuries according to the type of work conducted with forklift. The major differences in safety regulations between Korea and the major foreign countries were investigated. The opinions of field workers on the safety regulations were surveyed using e-mail or interview. As a result, it was found that preventing workers from contacting with the forklift is very important. To prevent accident due to movement of a stopped forklift, actions are necessary to prevent slip of a forklift. Also supervision is required to make workers fasten safety belt and to prohibit workers from using a forklift for undesignated purpose.

Survey on work platforms of the Mobile Scaffolding (이동식비계 작업발판의 사용 실태조사)

  • Choi, Seung-Ju;Choi, Don-Heung;Shin, Woon-Chul
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.2
    • /
    • pp.79-84
    • /
    • 2013
  • According to the statistics of occupational accidents in 2009, the scaffolds and work platforms were main objects causing fall accidents in construction sites. But many workers install and use the work platforms on the mobile scaffolding without considering about safety standards. We had conducted a nationwide survey about how workers obey safety standards for the work platforms of the mobile scaffolding. As the result of a survey, no one follow a gap standard between materials of work platforms and installation of toe board. And it is a low proportion that comply with the install of safety guard rails and the use of stoppers. This is lack of consciousness for the safety certification and regulations. For safe use a mobile scaffolding, It is needed to educate a manager on the safety standards and to develop a product to install and dismantle easily.

A Study on the Effects of S-100 Standard on VTS (S-100 표준이 VTS에 미치는 영향 연구)

  • Oh, Se-Woong;Shim, Woo-Seong;Suh, Sang-Hyun;Kim, Sun-Young
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2012.06a
    • /
    • pp.507-509
    • /
    • 2012
  • IHO has established S-100 Standard profiled from ISO 19100 GIS standards for standardization and improvement of hydrographic data and are developing S-10X Standards. IMO is implementing the e-Navigation strategy for maritime safety and marine environment protection and has established the CMDS as information standard framework which will be developed from the S-100 standard. The development domain of e-Navigation can be divided into onboard, communication network, onshore and VTS is a core actor in onshore system. In this study, we analyzed the effects of S-100 standard development on VTS through e-Navigation strategy of IMO and suggested the cooperation between hydrographic fields and VTS fields under e-Navigation strategy.

  • PDF

Development of a Standard Checklist for Protection to Electrical Accidents of Laboratory (연구실 전기사고방지를 위한 표준체크리스트개발)

  • Lee, Dong-Yoon
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.3
    • /
    • pp.108-115
    • /
    • 2011
  • This paper informs the standard guideline of electrical inspection for the University laboratories and R&D institutes. A routine electrical inspection is there to prevent an electric shock and electrical fire accident in the Lab. The main issue of this paper is to check the problem of a routine electrical inspection and this paper provides a detailed guideline of a checklist for the Lab which do not have detailed instruction. It mentions the standard model of an effective routine inspection to upgrade the weak electrical environment in the Lab. One of the main purposes of this paper is to develop a routine checklist to control the electrical environment in the Lab. The evaluation checklist we develop will then be applied to every Lab. Introducing an electrical safety checklist builds a clear standard guideline for a real safety check. This will be used as a regular routine check-up for every Lab. The goal of this paper is to enforce safety from electrical accidents in the lab and it will provide safety guidelines for every Lab.

A Study on Work Safety and Standard Contract for Popular Culture Production Staff (대중문화예술제작물스태프의 작업 안전과 표준계약에 관한 소고)

  • Kim, Si Yeol;Lee, Kyung Ho
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.10
    • /
    • pp.630-640
    • /
    • 2019
  • A series of recent events have laid the groundwork for discussions on the safety issues regarding production staff in the popular culture industry. In Korea, the standard contract has been pursued as a means of dealing with issues involving popular culture production staff. However, the existing standard contract failed to incorporate the characteristics and requirements in today's market, which greatly restricted its efficacy in real-world cases. Therefore, this study seeks to significantly improve the provisions in the standard contract that govern obligations between contractual parties, and the work safety of the production staff. To this end, considering the main causes of safety accidents and actual contracts, this study groups contractual provisions into several categories: the removal of adverse factors affecting optimal competency, factors causing individual staff's negligence, and external factors causing negligence. Then, this study proposes specific provisions to be included in each category.

Affecting Factors on Performance of Standard Precaution for Healthcare associated Infection Control and Prevention in Nursing Students: focused on Patient Safety Attitude, Empowerment, Awareness (간호대학생의 의료관련감염 관리를 위한 표준주의지침 수행도 영향요인 : 환자안전에 대한 태도, 임파워먼트, 인지도를 중심으로)

  • Park, Min Kyoung;Ahn, Mi Na
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.4
    • /
    • pp.265-275
    • /
    • 2019
  • The purpose of this study was to investigate the relationship between attitude toward patient safety, empowerment and awareness, performance of standard precaution for healthcare associated infection control and prevention and to identify the influencing factors of the performance in nursing students. The participants were 185 nursing students on one college in J city, Data collection was conducted from september 10 to 21, 2018. The collected data were analyzed with independent t-test, ANOVA, Pearson's correlation coefficient and stepwise multiple regression using SPSS Statistics 22.0 program. As a result of multiple regression analysis showed that the factors influencing the performance of the standard precaution were awareness, empowerment, participation in the patient safety campaign and the performance was explained by 51.0%. Therefore, In order to improve the performance of standard precaution for nursing students, various convergent education programs should be applied to raise awareness and improve empowerment, and it is necessary to seek ways for nursing students to participate actively in patient safety campaigns.

Establishment of a Standard Procedure for Safety Inspections of Bridges Using Drones (드론 활용 교량 안전점검을 위한 표준절차 정립)

  • Lee, Suk Bae;Lee, Kihong;Choi, Hyun Min;Lim, Chi Sung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.2
    • /
    • pp.281-290
    • /
    • 2022
  • In Korea, the number of national facilities for which a safety inspection is mandatory is increasing, and a safer safety inspection method is needed. This study aimed to increase the efficiency of the bridge safety inspection by enabling rapid exterior inspection while securing the safety of inspectors by using drones to perform the safety inspections of bridges, which had mainly relied on visual inspections. For the research, the Youngjong Grand Bridge in Incheon was selected as a test bed and was divided into four parts: the warren truss, suspension bridge main cable, main tower, and pier. It was possible to establish a five-step standard procedure for drone safety inspections. The step-by-step contents of the standard procedure obtained as a result of this research are: Step 1, facility information collection and analysis, Step 2, analysis of vulnerable parts and drone flight planning, Step 3, drone photography and data processing, Step 4, condition evaluation by external inspection, Step 5, building of external inspection diagram and database. Therefore, if the safety inspections of civil engineering facilities including bridges are performed according to this standard procedure, it is expected that these inspection can be carried out more systematically and efficiently.

A new method to calculate a standard set of finite cloud dose correction factors for the level 3 probabilistic safety assessment of nuclear power plants

  • Gee Man Lee;Woo Sik Jung
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1225-1233
    • /
    • 2024
  • Level 3 probabilistic safety assessment (PSA) is performed to calculate radionuclide concentrations and exposure dose resulting from nuclear power plant accidents. To calculate the external exposure dose from the released radioactive materials, the radionuclide concentrations are multiplied by two factors of dose coefficient and a finite cloud dose correction factor (FCDCF), and the obtained values are summed. This indicates that a standard set of FCDCFs is required for external exposure dose calculations. To calculate a standard set of FCDCFs, the effective distance from the release point to the receptor along the wind direction should be predetermined. The TID-24190 document published in 1968 provides equations to calculate FCDCFs and the resultant standard set of FCDCFs. However, it does not provide any explanation on the effective distance required to calculate the standard set of FCDCFs. In 2021, Sandia National Laboratories (SNLs) proposed a method to predetermine finite effective distances depending on the atmospheric stability classes A to F, which results in six standard sets of FCDCFs. Meanwhile, independently of the SNLs, the authors of this paper discovered that an infinite effective distance assumption is a very reasonable approach to calculate one standard set of FCDCFs, and they implemented it into the multi-unit radiological consequence calculator (MURCC) code, which is a post-processor of the level 3 PSA codes. This paper calculates and compares short- and long-range FCDCFs calculated using the TID-24190, SNLs method, and MURCC method, and explains the strength of the MURCC method over the SNLs method. Although six standard sets of FCDCFs are required by the SNLs method, one standard sets of FCDCFs are sufficient by the MURCC method. Additionally, the use of the MURCC method and its resultant FCDCFs for level 3 PSA was strongly recommended.

Stability Evaluation of National Reference Standards for Blood Products in Korea

  • Park, Tae Jun;Choi, Chan Woong;Oh, Ho Kyung;Kim, Jae Ok;Kim, Byung Kuk;Kang, Hyun Kyung;Kwon, Eun Jeong;Gweon, Eun Jeong;Park, Sang Jin;Kang, Ho Il;Jung, Ki Kyung;Park, Sang Mi;Kim, Ji Hye;Han, Ki Won;Jeong, Ja Young
    • Toxicological Research
    • /
    • v.33 no.3
    • /
    • pp.225-231
    • /
    • 2017
  • National reference standards (NRSs) for biologics are established through potency estimation by a multi-center joint study of standard materials used in the approval process for national lot release and quality control of vaccines, blood products, and other biologics. In this study, a stability evaluation was conducted to determine whether the potency of NRSs for six blood products was being maintained at a consistent level in Korea. The present study conducted real-time stability tests via in-vivo/in-vitro bioassay on NRSs for blood coagulation factor VIII concentrate (2nd standard), antithrombin concentrate, prekallikrein activator, anti-hepatitis B immunoglobulin, blood coagulation factor IX concentrate, and anti-tetanus human immunoglobulin, as well as a trend analysis using cumulative annual results. The real-time stability test results showed that the mean potency of six NRSs was all within the control limit. In the trend analysis, the potency of NRS for blood coagulation factor VIII concentrate (2nd standard) showed a decreasing trend, while the potency of all other products had been stably maintained. The present study confirmed that the mean potency of NRSs for six blood products had been stably maintained in Korea. The findings of the present study establish a foundation that can ensure the quality of NRSs for biologics in Korea, and it is expected to make a major contribution to the supply of high-quality biologics.