• 제목/요약/키워드: Safety protection system

검색결과 1,053건 처리시간 0.025초

선박용 ICCP 제어 감시 시스템에 관한 연구 (A Study on the ICCP Control and Monitoring System for Ship)

  • 이지영;오진석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권4호
    • /
    • pp.667-674
    • /
    • 2004
  • This thesis is about the Impressed Current Cathodic Protection (ICCP) control and monitoring system. which brings protection against the corrosion of the ship's hull in the sea environments. The ICCP system is composed of a power supply. anode. reference electrode and controller. AC sources from the ship's generator are converted to DC sources in terms of power supply, and a protection current is sent to ship's hull though anode. The controller fully senses whether or not the detected potential is within a range of protection of ship's hull and then it is automatically controlled to increase or decrease the amount of protective current to be sent to the anode. The monitoring system with RS 232/485 communication is also studied in order to check the normal state of the system at a long period. because an operator does not always watch over this system and thus the system cannot operate well because of his or her negligent management. Since the vessel always navigates in the sea. an characteristics experiment of the ICCP system is conducted by introducing various corrosive environmental factors such as velocity, resistivity, dissolved oxygen, PH, temperature and contamination degree. These results must be referred to when the ICCP system is set up. In short. the ICCP is a multi-system for use on ships and on land structures because it includes a safety device. It is suggested that this system can accomodate a ship's automation and will be very useful.

A Study on Fire Spread between Office Room and Atrium in the Atrium Building

  • Lee, Su-Kyung;Kim, Jong-Hoon;Ko, Han-Mog
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.345-352
    • /
    • 1997
  • We could analyse the fire behavior using the developed software for fire safety assessment in a large space such as atrium. But Korean building law hasn't admitted the result of fire risk assessment in atrium. In the legislation fire resistant wall or shutter must be required between atrium and office rooms, That has obstructed development of building design and fire protection technique in Korea. From this point of view, we made scenarios of fire spread between atrium and office rooms, and then computed fire spread and fire phenomena using FASTLite and Breakl. In this study, we can decide that fire compartmentalization between atrium and office rooms doesn't require in Atrium building if the material and fire protection system were reliable. Consequently, Korean Fire Protection Regulations have to consider in direction of increasing freedom of building.

  • PDF

유연성 방호책을 이용한 철도변 낙석방호사례 (Flexible Barrier System for Rockfall Protection)

  • 최승일;유병옥;김경석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 사면안정학술발표회
    • /
    • pp.103-116
    • /
    • 2003
  • Rockfall Protection fence is one of the most common rockfall Protection methods in Korea. If rockfall protection fences are required along the road or railway, their location, height and capacity, in terms of the maximum kinetic energy that they can absorb, should be specified. Within this paper, the best practice of rockfall barrier is introduced. Modern rockfall simulations as a means to define risks, protection requirements, dynamic loading and height of potential structures and selection of appropriate placement is presented. Technical possibilities of rockfall barriers and their actual limits are presented. Safety concepts based on probabilistic approaches are proposed. Recent studies peformed in other countries show that Flexible Barriers are also a feasible system to stop and retain debris flows. Finally an outlook onto further development is given.

  • PDF

IEC 표준에 의한 고장전류 계산과 보호협조 (Fault Current Calculation and Coordination by IEC Standards)

  • 손석금
    • 조명전기설비학회논문지
    • /
    • 제28권12호
    • /
    • pp.6-12
    • /
    • 2014
  • The safety and reliability of the power system short-circuit current, the short-circuit current depends on the failure to obtain the objective is to quickly eliminate the breaking capacity of the circuit-breaker selection of the cable, the insulation of electrical equipment and protective relay an important factor in determining the level correction and protective relay selection scheme to be meaningful. Standards used in the domestic circuit breaker is applied to the production of IEC standard, but the American National Standards (ANSI / IEEE) by NEMA specification of the fault current calculations and the application of the asymmetric coefficient Korea. Therefore, in this paper, the IEC 60909 standard IEC breaker fault current calculation method and the method for selection of system configurations reviewed and protection system for reviewing the configuration of various protective relays appropriate correction and the correction value is main protection, back-up protection the equipment so that the period of protection relay coordination to minimize accidents and accident protection to minimize interruptions proposed for cooperation.

차량용 변속기의 조향안전화 제어장치의 개발 (Development of the Safety Steering System of Motor Vehicles Transmission)

  • 송창섭
    • 한국생산제조학회지
    • /
    • 제4권2호
    • /
    • pp.12-17
    • /
    • 1995
  • The operation of heavy tracked vehicle has the problems in the steering that made by misoperations. The protection device is applied to the vehicles. But that device is applied to the vehicles. But that device has the engine stop and over load condition problems. the steering safety system is developed on the basis of clutch slip that proved the durability in the dynamo test and field test. The steering safety system caused the performance improvement of vehicles when steering.

  • PDF

APPLICATION OF PERFORMANCED BASED DESIGN IN FIRE PROTECTION ENGINEERING

  • Cha, David S.
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.423-438
    • /
    • 1997
  • Today's building and fire prevention codes are mostly prescriptive. Prescriptive codes are based on major fires in earlier years that created a need for specific building provision. These codes provide a minimum level of safety. As the general and engineering uses of computers have increased over the years, so has use of computers in the fire protection engineering. This has allowed fire protection engineers to develop alternative approaches to solve today's fire protection problems or to evaluate the performance of a specific fire safety goal. A performance based approach to building and fire codes involves the following: 1) identifying specific goals, such as, safely getting out of the building in 10 minutes, 2) obtain conceptual approval from authorities, 3) define performance level, 4) develop design solutions and identify tools such as, fire tests, models, or methods, to demonstrate that a design will meet the fire protection objective 5) test solutions, 6) present test method and results to the authorities. Some people in the fire protection community consider this to be nothing more than an intellectual exercise, while the others view it as a way to reduce expenses on large project$^4$ Others in fire protection community view this as a way to refine the design process to design fire protection systems to better protect the fire hazards. This paper will focus on application of these tools, specifically computer fire models, to actual cases such as: design of a smoke control system heat transfer analysis and egress of building occupants during potential fires.

  • PDF

차세대 원자력 발전소에서의 발전소보호계통 Prototype 기능의 구현 (Prototype Development for KNGR Plant Protection Systems)

  • 박종범;김창호;조황
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 B
    • /
    • pp.807-809
    • /
    • 1998
  • Plant Protection Systems(PPS) are those systems that initiate safety actions to mitigate the consequences of design basis events by sending signals to Reactor Trip Switch Gear System(RTSS) and Engineered Safety Features-Component Control Systems(ESF-CCS). This paper illustrates distinctive features and improved design concepts of Korea Next Generation Reactor(KNGR) based on the experience obtained through prototyping of PPS.

  • PDF

Optimization of preventive maintenance of nuclear safety-class DCS based on reliability modeling

  • Peng, Hao;Wang, Yuanbing;Zhang, Xu;Hu, Qingren;Xu, Biao
    • Nuclear Engineering and Technology
    • /
    • 제54권10호
    • /
    • pp.3595-3603
    • /
    • 2022
  • Nuclear safety-class DCS is used for nuclear reactor protection function, which is one of the key facilities to ensure nuclear power plant safety, the maintenance for DCS to keep system in a high reliability is significant. In this paper, Nuclear safety-class DCS system developed by the Nuclear Power Institute of China is investigated, the model of reliability estimation considering nuclear power plant emergency trip control process is carried out using Markov transfer process. According to the System-Subgroup-Module hierarchical iteration calculation, the evolution curve of failure probability is established, and the preventive maintenance optimization strategy is constructed combining reliability numerical calculation and periodic overhaul interval of nuclear power plant, which could provide a quantitative basis for the maintenance decision of DCS system.

원전 안전통신망을 위한 TDMA 기반의 프로토콜 개발 (Development of TDMA-Based Protocol for Safety Networks in Nuclear Power Plants)

  • 김동훈;박성우;김정헌
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권7호
    • /
    • pp.303-312
    • /
    • 2006
  • This paper proposes the architecture and protocol of a data communication network for the safety system in nuclear power plants. First, we establish four design criteria with respect to determinability, reliability, separation and isolation, and verification/validation. Next we construct the architecture of the safety network for the following systems: PPS (Plant Protection System), ESF-CCS (Engineered Safety Features-Component Control System) and CPCS (Core Protection Calculator System). The safety network consists of 12 sub-networks and takes the form of a hierarchical star. Among 163 communication nodes are about 1600 origin-destination (OD) pairs created on their traffic demands. The OD pairs are allowed to exchange data only during the pre-assigned time slots. Finally, the communication protocol is designed in consideration of design factors for the safety network. The design factors include a network topology of star, fiber-optic transmission media, synchronous data transfer mode, point-to-point link configuration, and a periodic transmission schedule etc. The resulting protocol is the modification of IEEE 802.15.4 (LR-WPAN) MAC combined with IEEE 802.3 (Fast Ethernet) PHY. The MAC layer of IEEE 802.15.4 is simplified by eliminating some unnecessary (unctions. Most importantly, the optional TDMA-like scheme called the guaranteed time slot (GTS) is changed to be mandatory to guarantee the periodic data transfer. The proposed protocol is formally specified using the SDL. By performing simulations and validations using Telelogic Tau SDL Suite, we find that the proposed safety protocol fits well with the characteristics and the requirements of the safety system in nuclear power plants.

전기철도 AT급전방식 보호시스템 최적구성 방안 연구 (A Study on the Protection System for AT Feeding on the Electric Railway)

  • 창상훈;이형수;홍재승;김정훈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1999년도 추계학술대회 논문집
    • /
    • pp.344-351
    • /
    • 1999
  • The safe operation of electro railways is greatly dependant on its protective systems. The system so-called Fault Protection Wire(FW) is now widely adapted to protect in AT feeding systems. It is connected between the feeder and trolley circuit to return the fault current to autotransfonmers at substation. This paper computed the distribution of fault currents at FW in the system and also evaluated the safety from electric shock when ground fault or flashover occur in the feeding system. The results show FW is useful to protect power supply network from fault in electric railways

  • PDF