• Title/Summary/Keyword: Safety of passenger

Search Result 714, Processing Time 0.027 seconds

Full-scale Fire Suppression Test for Application of Water Mist System in Road Tunnel (미분무수 소화시스템의 도로터널 적용을 위한 실물 화재 실험)

  • Han, Yong-Shik;Choi, Byung-Il;Kim, Myung-Bae;Lee, Yu-Whan;So, Soo-Hyun
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.51-56
    • /
    • 2011
  • The full-scale experiments are carried out to investigate the fire suppression characteristics of water-based fire fighting systems in a road tunnel. Applied systems are the low-pressure water spray system at 3.5 bar and the high-pressure water mist system at 60 bar. The water flow rate of the high-pressure system is one sixth only of the water spray system. A passenger car and a heptane fuel pan with area of $1.4m^2$ are used as fire sources. A blower system is installed at the tunnel exit to realize the longitudinal ventilation conditions (0.9~3.8 m/s) in the tunnel. Temperatures from the fire source to the down-stream direction are measured by K-type thermocouple trees. The experimental results show that the cooling effect of the high pressure water mist system in the test conditions were equivalent to that of the low pressure water spray system for B-class fire.

Case Study of the Longest Roadway Tunnel in Korea, Baehuryeong Tunnel (국내 최장대 양방향 도로터널 설계사례-배후령터널)

  • Lee Seon-Bok;Je Hae-Chan
    • Tunnel and Underground Space
    • /
    • v.15 no.6 s.59
    • /
    • pp.432-440
    • /
    • 2005
  • Baehuryeong tunnel connects Chuncheon with Hwacheon in Kangwon, Korea, This tunnel is a single tunnel with 5,057 m long and two bidirectional lanes which will be extended into low lanes in the future. The estimated construction period of Baehuryeong tunnel is approximately 55 months. This tunnel will become the longest bidirectional roadway tunnel in Korea. Compared to a twin tunnel, a bidirectional single tunnel has two major disadvantages with regard to the ventilation system and ease of escape during fire. For these reasons, a service tunnel and the transverse ventilation system are planned first time in Korea. In case of fire, the tunnel ventilation design aims to maintain a smoke free layer for passenger evacuation. The geology of Baehuryeong tunnel site is mainly composed of gneiss and granite. Baehuryeong fault is a mainly large scale fault which stands vertical and parallels with tunnel direction. The influenced zone of this fault is within 70 m. Baehuryeong tunnel was designed that it was separated with the distance of more than 100 m from Baehuryeong fault for its safety.

A Study for determining the braked weight of Iran DMU using UIC 544-1 (UIC 544-1을 이용한 이란동차 Braked Weight 산출에 관한 연구)

  • Yun, Gi-Seok;Jeon, Woon-Ho
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1624-1633
    • /
    • 2009
  • Brake system in railway train operates to reduce the speed of the train or to stop the train via changing the kinematic energy into heat energy for emission and so brake system makes an important rule to transport passenger and cargo for safety operation. Recently operators have a matter of grave concern for the verification of performance in brake system. To verify the exact performance of brake system, most of brake test has been carried out on real operating track condition. Therefore we will determine the braked weight of indirect brake system applied in Iran DMU(Diesel Multiple Unit) in accordance with mc leaflet 544-1, which is to enable Iran DMU to achieve the required braking distances in defined situation.

  • PDF

The Effects of Airport Passengers, CCTV, Signal Device & Electric Alarms on Export to Korea (공항 환승여객과 CCTV, 전기진단 및 의료기기, 전기경보 및 신호장치의 수출이 한국 수출에 미치는 영향 분석)

  • Jang, Ye-Jin;Choi, Jeong-Il
    • Convergence Security Journal
    • /
    • v.20 no.4
    • /
    • pp.217-225
    • /
    • 2020
  • In recent years, the "social distance" has drastically reduced overseas travelers. On the other hand, for personal safety and security, it is expected that interest and demand for CCTV, electric alarm and signaling devices, electric diagnostics and medical devices will increase significantly. The purpose of this paper is to find out the effect of airport transfer passengers and exports of CCTV, electrical diagnostics and medical devices, electrical alarms and signaling devices on exports to Korea, and the synchronism of each variable. To this end, this study used a total of 231 monthly data from January 2000 to April 2020 in the National Statistics Service. As a result of empirical analysis, CCTV and electrical diagnostics and medical devices showed relatively high synchronization with respect to exports to Korea. Electric alarms & signaling devices and transit passengers also showed a certain level of synchronization with exports, but were relatively weak.

Experimental Analysis of the Impact on the Aggressive Following Vehicle by Passenger Vehicle Tinting (승용차 틴팅이 조급한 성향의 후미차량에 미치는 영향에 대한 실험적 분석)

  • Kang, Jong Ho;Lee, Chungwon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.3D
    • /
    • pp.363-371
    • /
    • 2009
  • The purpose of this study is to verify the safety issue of the tinted vehicle based on the field study as well as the issue of the capacity reduction from the tinted vehicle. Through this study, an innovative experimental method to verify the issues was developed using RTK GPS receivers, and a data collection was conducted using the developed experimental method. Using the collected data, the effects of the ahead vehicle with the windows tinted on the traffic condition such as headways and acceleration noise were analyzed to test that the ahead vehicle with windows tinted too darkly affects the increasing vehicle maneuver as following the degree of tinting. This study was conducted as a frontier study and more studies, for example, full scale analyses considering various road and vehicle conditions need to be conducted in the future.

A Study on a Elevator Emergency Call Device System and Performance Evaluation based on ICT for Efficient Handling in Emergency Situation (위급상황 시 효율적인 대처를 위한 ICT 기반의 엘리베이터 비상통화장치 시스템 및 성능 비교 연구)

  • Jung, Se-Hoon;Park, Sung-Kyun;Park, Hong-Jun;So, Won-Ho;Park, Dong-Kook;Sim, Chun-Bo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.4
    • /
    • pp.449-459
    • /
    • 2015
  • A lot of people were trapped in elevators without power supply when BLACK-OUT situation occurred in 2011. The telephone network of control room connected to the elevators had problem operating poorly. In this paper we propose an ICT based elevator emergency call device prototype system and evaluate the performance of the system. The proposed system quickly responds in emergency situation to guarantee passenger safety. For the goal, firstly the system tries to connect to a control room. If it fails the system attempts to call numbers for emergency contact and a rescue team sequentially. The system is designed to quickly support emergency contact as well. Finally, the information of elevator failure is rapidly transferred to the failure process device by the proposed system.

Designing FMH Impact-Absorbing Structure by Using Subcomponent Collapse Simulation (단품 압궤 시뮬레이션을 이용한 FMH 충격흡수부재의 설계방법에 관한 연구)

  • Kim, Ji-Hun;Jun, In-Ki;Choi, Jae-Min;Kim, Sung-Hun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.8
    • /
    • pp.1113-1118
    • /
    • 2010
  • It is requested that the interior compartment of a passenger vehicle must be satisfied with the FMVSS201U regulation, FMH impact test. It is needed the design methodology to find the appropriate structure about the FMH impact. When designing the impact-absorbing structure for the FMH impact test, it is to be noted that the impact absorber must have different performance considering the stiffness of the vehicle as the impact position and approach angle of FMH. In this study, an efficient design methodology was developed by using subcomponent collapse simulation instead of conducting full-vehicle simulation, thereby reducing the time and resources spent. Further, this unit-model simulation helps optimize the impact absorbing structure.

The Study of fire Driven flow and Smoke Exhaust Efficiency for PSD Installation Subway Station (PSD 설치역사의 화재유동 및 배연 효율 연구)

  • Jang, Yong-Jun;Lee, Chang-Hyun;Kim, Hag-Beom;Kim, Jin-Ho
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1054-1061
    • /
    • 2009
  • This research was performed with emphasis on fire driven flow behavior and smoke exhaust efficiency which depend on the presence of PSD which are being installed domestically and overseas. For simulation, Jung-ang-ro station of Dae-gu subway station was chosen as model, and fire driven flow analysis was performed by using FDS as flow analysis code. Since many calculation time are required for calculation due to increase in the number of grid as the entire station is modeled, simulation was conducted in parallel processing technique. The fire driven flow analysis was analyzed case by case with composing fire scenario to compare fire driven flow and smoke exhaust efficiency changes depending on the presence of PSD. For fire scale, fire strength of 10MW was studied by referring to NFPA-l30. The calculation results were analyzed with focus on passenger safety by referring to NFPA-130.

  • PDF

Analysis & investigation of EMI dispersion for protection aviation frequency (항공주파수 보호를 위한 전자파방해(EMI)분포조사 및 분석)

  • Park, Duck-Je
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.5
    • /
    • pp.714-721
    • /
    • 2011
  • In this paper, developing management programs for EMI tracking can navigate the site quickly and solve EMI tracking cause and location to use materials such as analysis of air accidents, EMI site location data of 1000 RF companys, radio wave spectrum analysis and audio data. these data are databased and used comparable data. Also, EMI has been prevented by establishing continuous monitoring system through a 24-hour surveillance. Therefore we were able to provide high quality air waves in order to prevent aircraft accidents. In addition, radar control staff of Korea Airports Corporation against passenger aircraft that will prevent the worst aircraft accident have been established based to continue periodic aviation frequency protection and Portable Electronic Devices(PED) on board aircraft to prevent the culture of safety campaign.

A Study on the Design of Onboard Speed Profile of the ETCS-L2 System (ETCS-L2 차상 속도 프로파일 설계에 대한 연구)

  • Lee, Jong-Seong;Jeon, Jae-Hun;Jung, Gyung-Jang;Kang, Deok-Won
    • Journal of the Korean Society for Railway
    • /
    • v.17 no.5
    • /
    • pp.349-354
    • /
    • 2014
  • Other foreign countries already apply ETCS LEVEL 2 in signaling systems. It provides added functions to control a train using wireless communication compared with ETCS LEVEL 1. Nowadays, the ETCS LEVEL 2 system is being applied on revenue services more and more frequently. Therefore, it is necessary to develop ETCS LEVEL 2 to apply in this country. The advanced technology of the ETCS LEVEL 2 system provides continuous control for train protection, and ATP function, by comparing discontinuous controls on ETCS LEVEL 1. ETCS LEVEL 2 is a better system model for improving passenger safety. This paper describes the design of an onboard speed profile for the ETCS LEVEL 2 system and it forecasts the future of ETCS.