• Title/Summary/Keyword: Safety monitoring

Search Result 2,899, Processing Time 0.029 seconds

A novel monitoring system for fatigue crack length of compact tensile specimen in liquid lead-bismuth eutectic

  • Baoquan Xue;Jibo Tan;Xinqiang Wu;Ziyu Zhang;Xiang Wang
    • Nuclear Engineering and Technology
    • /
    • v.56 no.5
    • /
    • pp.1887-1894
    • /
    • 2024
  • Fatigue strength of the structural materials of lead-cooled fast reactors (LFRs) and accelerator-driven systems (ADS) may be degraded in liquid metal (Lead or lead-bismuth eutectic (LBE)) environments. The fatigue crack growth (FCG) data of structural materials in liquid LBE are necessary for damage tolerance design, safety assessment and life management of key equipment. A novel monitoring system for fatigue crack length was designed on the compliance method and the monitor technology of crack opening displacement (COD) of CT specimens by the linear variable differential transformers (LVDT) system. It can be used to predict the crack length by monitoring the COD of CT specimens in harsh high-temperature liquid LBE using a LVDT system. The prediction accuracy of this system was verified by FCG experiments in room temperature air and liquid LBE at 150, 250 and 350 ℃. The first results obtained in the FCG test for T91 steel in liquid LBE at 350 ℃ are presented.

Assessment of correlation between markers of ambient monitoring and biological monitoring of dimethylformamide for workers in synthetic leather manufacturing factories in Korea (국내 합성피혁제조업 근로자에 대한 디메틸포름아미드의 공기중 농도와 생물학적 노출지표간의 상관성 평가)

  • Hwang, Yang In;Lee, Mi-Young;Chung, Yun Kyung;Kim, Eun A
    • Analytical Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.315-325
    • /
    • 2013
  • The possibility of acute hepatotoxicity caused by dimethylformamide (DMF) requires regular monitoring of the workers who are using DMF to prevent the occupational disease. The authors performed ambient and biological monitoring of workers involved in synthetic leather manufacturing processes using DMF to assess the correlation between the markers of ambient and biological monitoring of DMF. The authors monitored 142 workers occupationally exposed to DMF from 19 workshops in the synthetic leather and ink manufacturing industries located in northern region of Gyeonggi-do. The subjects answered questionnaire on work procedure and use of personal protective equipment to be classified by exposure type. DMF in air samples collected using personal air samplers, diffusive and active sampler, was analysed using gas chromatograph-flame ionization detector (GC-FID) with DB-FFAP column (length 30 m, i.d. 0.25 mm, film thickness 0.25 ${\mu}m$). Urinary N-methylformamide (NMF) was analysed using gas chromatograph-mass selective detector (GC-MSD) at selected ion monitoring (SIM) mode with DB-624 column (length 60 m, i.d. 0.25 mm, film thickness 1.40 ${\mu}m$). Geometric mean (GM) and geometric standard deviation (GSD) of the ambient DMF was $6.85{\pm}3.43$ ppm, and GM and GSD of urinary NMF was $42.3{\pm}2.7$ mg/L. The ratio of subjects with DMF level over 10 ppm was 44%, and those with urinary NMF over 15 mg/L was 87%. NMF in urine adjusted by DMF in air was $4.61{\pm}2.57$ mg/L/ppm and $9.50{\pm}2.41$ mg/L/ppm, respectively, with or without respirator. There was seasonal differences of NMF in urine adjusted by DMF in air, $7.63{\pm}2.74$ mg/L/ppm in summer and $4.53{\pm}2.29$ mg/L/ppm in winter. The urinary NMF concentration which corresponds to 10 ppm of ambient DMF was 52.7 mg/L (r=0.650, n=128). Considering the difference of the route of exposure which resulted from the compliance of wearing personal protective equipment, the estimated contribution of respiratory and dermal exposure route for DMF was 48.5% vs. 51.5%.

A Study on the Improvement of Subcontractors' Safety Management System in Construction Industries (건설업 협력회사 안전수준 향상 방안에 관한 연구)

  • Lee, Jae Yun;Oh, Tae Keun
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.78-84
    • /
    • 2017
  • Subcontractors have an increased risk of accidents compared to large contractors. Subcontractors' safety management system is in close association with workers in construction sites. Contractors should strengthen subcontractors' roll and responsibility and provide continual support to prevent an accident. And also these supporting system should be provided to subcontractors' headquarters as well as construction site. Contractors' priority management for subcontractors safety should be transferred from the post management for disciplinary action to the preventive management to improve subcontractors participation and safety performance. Subcontractors can not establish the safety management system with just a one time supporting only. Contractors support and monitoring should be provided to subcontractors regularly and continuously to establish their self safety management system. The subcontractors safety management system improvement program(SSMSIP) suggested in this study will be a effective supporting system for subcontractors to establish and improve their safety management system. If we carry out the objective and quantitative evaluations and supporting system such as SSMSIP and provide the consequential incentive program to subcontractors, it can contribute to the accident reduction.

The Feasibility Study on a High-Temperature Application of the Magnetostrictive Transducer Employing a Thin Fe-Co Alloy Patch

  • Heo, Tae-Hoon;Park, Jae-Ha;Ahn, Bong-Young;Cho, Seung-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.3
    • /
    • pp.278-286
    • /
    • 2011
  • The on-line monitoring for the wall thinning in secondary system has been considered one of main issues for the safety of nuclear power plants. To establish the on-line monitoring technique for the pipe wall thinning, the development of the ultrasonic transducer working in high-temperature is very important. In this investigation, the magnetostrictive transducer is concerned for high temperature condition up to $300^{\circ}C$. The magnetostrictive transducer has many advantages such as high working temperature, durability, cost-effectiveness, and shear waves, most of all. A thin Fe-Co alloy patch whose Curie temperature is over $900^{\circ}C$ was employed as a ferromagnetic material for magnetostriction. Wave transduction experiments in various temperature were carried out and the effect of bias magnets was considered together with the dry coupling performance of the transducer. From experimental results, consequently, it was found that the magnetostrictive transducer works stable even in high temperature up to $300^{\circ}C$ and can be a promising method for the on-line monitoring of the wall thinning in nuclear power plants.

Implementation of USN based Personal Safety Belt Monitoring System (USN 기반 개인 안전벨트 모니터링 시스템의 구현)

  • Jeong, Seon-Jae;Yim, Jae-Hong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.3
    • /
    • pp.724-730
    • /
    • 2015
  • The safety-related accident in which the field operators of all sorts of industrial sites don't fasten the seat belt properly and which it generates is the tendency that it increases constantly every year. By sounding the announcement sound in case the operator did not fasten the seat belt and the person seat belt monitoring system proposed in this paper progressed the work the operator fastened the seat belt properly. In addition, at the same time with that, since the administrator monitored the seat belt wearing or no of the operators on a real time basis the safety-related accident which did not wear the safety equipment properly and which it generates was prevented.

Safety assessment of generation III nuclear power plant buildings subjected to commercial aircraft crash part III: Engine missile impacting SC plate

  • Xu, Z.Y.;Wu, H.;Liu, X.;Qu, Y.G.;Li, Z.C.;Fang, Q.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.2
    • /
    • pp.417-428
    • /
    • 2020
  • Investigations of the commercial aircraft impact effect on nuclear island infrastructures have been drawing extensive attention, and this paper aims to perform the safety assessment of Generation III nuclear power plant (NPP) buildings subjected to typical commercial aircrafts crash. At present Part III, the local damage of the rigid components of aircraft, e.g., engine and landing gear, impacting the steel concrete (SC) structures of NPP containment is mainly discussed. Two typical SC target panels with the thicknesses of 40 mm and 100 mm, as well as the steel cylindrical projectile with a mass of 2.15 kg and a diameter of 80 mm are fabricated. By using a large-caliber air gas gun, both the projectile penetration and perforation test are conducted, in which the striking velocities were ranged from 96 m/s to 157 m/s. The bulging velocity and the maximal deflection of rear steel plate, as well as penetration depth of projectile are derived, and the local deformation and failure modes of SC panels are assessed experimentally. Then, the commercial finite element program LS-DYNA is utilized to perform the numerical simulations, by comparisons with the experimental and simulated projectile impact process and SC panel damage, the numerical algorithm, constitutive models and the corresponding parameters are verified. The present work can provide helpful references for the evaluation of the local impact resistance of NPP buildings against the aircraft engine.

Study of Hydrogen Bus Operational Safety Monitoring Method through Driving Data Analysis (주행 데이터 분석을 통한 수소버스 운행안전 모니터링 기법 연구)

  • Hyunmi Lee;Insik Lee;Yongju Yi;Jeong-Ah Jang;Siwoo Kim;Sojung Sim
    • Journal of Auto-vehicle Safety Association
    • /
    • v.15 no.4
    • /
    • pp.58-64
    • /
    • 2023
  • The adoption of hydrogen-powered Elec is expanding globally. Hydrogen is recognized as a potentially hazardous energy source, and safety assessment is crucial for the development of plans to supply hydrogen-powered electric buses. Hydrogen gas leakage can have a significant impact during bus operations, and continuous hydrogen leakage in hydrogen-powered vehicles can result in fatal accidents. In this study, information about hydrogen leakage is collected through sensors installed within the vehicles and is measured when the sensor detects a leak. The study also proposes the use of Pseudo Fuel Leakage (PFL, %) as an additional indicator for evaluating and monitoring hydrogen safety and leakage.

Medical Information Event Monitoring System based on Sense and Respond (Sense and Respond 기반의 의료정보 이벤트 모니터링 시스템)

  • Kang, Un-Gu;Lee, Young-Ho;Kim, Si-Ra;Yoon, Young-Mi
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.8
    • /
    • pp.138-146
    • /
    • 2009
  • Recently big-sized hospitals showed their interest in medical information event monitoring system based on Sense and Respond in order to give patients in emergency a safer medical treatment. In this paper we implemented medical information event monitoring system based on Sense and Respond which stand on event and monitoring process. This system consists of event definition, event extraction, event delivery, and monitoring. It ensures real-time response by grasping and delivering medical information in real-time, and well-balanced understanding of information for hospital management by real-time tracking. Also early confrontation case by case by, event delivery make the safety of patients be secured, the efficiency of hospital can be maximized by early grasping the problems in hospital management problems.

Site Monitoring and investigation plan for LILW disposal (방사성폐기물 처분장 부지감시 계획)

  • Baek, Seung-Jong
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.4
    • /
    • pp.369-385
    • /
    • 2008
  • The purpose of site monitoring and investigation is to offer the basic data for performance assessment and design of low- and intermediate-level radioactive waste(LILW) disposal facility by monitoring variations of main site properties continually in the stage of pre-operation, operation and post-closure. Main contents of site monitoring are as follows. In the stage of pre-operation, suitability evaluation for disposal facility and monitoring for constructing and operating disposal facility are performed. In the operation period, monitoring is performed including surroundings to research the influence to environment with operating disposal facility and operate safely and efficiently. In the post-closure period, monitoring about major site properties is performed to prevent the effect of radioactive waste from disposal facility and to secure long-term safety.

  • PDF

Trends and Implications for Driver Status Monitoring in Autonomous Vehicles (자율주행차량 운전자 모니터링에 대한 동향 및 시사점)

  • M. Chang;D.W. Kang;E.H. Jang;W.J. Kim;D.S. Yoon;J.D. Choi
    • Electronics and Telecommunications Trends
    • /
    • v.38 no.6
    • /
    • pp.31-40
    • /
    • 2023
  • Given recent accidents involving autonomous vehicles, driver monitoring technology related to the transition of control in autonomous vehicles is gaining prominence. Driver status monitoring systems recognize the driver's level of alertness and identify possible impairments in the driving ability owing to conditions including drowsiness and distraction. In autonomous vehicles, predictive factors for the transition to manual driving should also be included. During traditional human driving, monitoring the driver's status is relatively straightforward owing to the consistency of crucial cues, such as the driver's location, head orientation, gaze direction, and hand placement. However, monitoring becomes more challenging during autonomous driving because of the absence of direct manual control and the driver's engagement in other activities, which may obscure the accurate assessment of the driver's readiness to intervene. Hence, safety-ensuring technology must be balanced with user experience in autonomous driving. We explore relevant global and domestic regulations, the new car assessment program, and related standards to extract requirements for driver status monitoring. This kind of monitoring can both enhance the autonomous driving performance and contribute to the overall safety of autonomous vehicles on the road.