• Title/Summary/Keyword: Safety Structure

Search Result 4,496, Processing Time 0.034 seconds

Plans for systematizing Railway Safety Regulations using a New Model for Railway Safety System Architecture (철도안전시스템 아키텍처 모델링을 통한 안전규제 체계화 방안 연구)

  • Park Young-Su;Cho Yeon-Ok;Hong Seon-Ho
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.7-14
    • /
    • 2005
  • A Structure of a system is usually described as same as an architecture, but they are basically different. The architecture has a broader meaning than a system structure. In other words, an architecture can include many of system structures. So, to define the architecture, we need to consider how functions of a system are consisted and integrated. The architecture defined is applicable to railway safety management systems, and it can be made as a new model for railway safety systems, which is useful to systematize railway safety regulations. To establish the architecture as applicable to railway safety regulations, it is required to compare between regulation relations by analyzing roles before/after executing railway safety regulations. Therefore, in this research, we reviewed and classified different types of regulation conditions and safety requirements for railway systems and a variety of conditions before/after railway safety regulations changes are compared by defining system architectures subject to National railway safety.

  • PDF

A Study on Estimation of Structure Damage caused by VCE (VCE에 의한 건물피해예측에 관한 연구)

  • Leem, Sa-Hwan;Lee, Jong-Rark;Huh, Yong-Jeong
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.5
    • /
    • pp.65-70
    • /
    • 2007
  • This paper is estimation of structure damage caused by VCE(Vapor Cloud Explosion) in enclosure. As we estimate the influence of damage which occur at gas facility in factory. We can utilize the elementary data of safety distance. In this study, the influence of over-pressure caused by VCE in enclosure was calculated by using the Hopkinson's scaling law and the accident damage was estimated by applying the influence on the adjacent structure into the probit model. As a result of the damage estimation conducted by using the probit model, both the damage possibility of explosion overpressure to structures of 20 meters away and to glass bursting of 80 meters away was nearly zero in open space explosion.

Structural Design of CN fan Lift of 5 tonne Fans for Air Conditioner (5톤 송풍기용 FAN 인양기 구조설계)

  • Lee, Hyoungwook;Lee, Gwanghee
    • Journal of Institute of Convergence Technology
    • /
    • v.9 no.1
    • /
    • pp.25-30
    • /
    • 2019
  • Normal cranes cannot be used to move the fan inside the high-rise factories. Due to the size of the fan and safety accidents, there is a need for a structure capable of lifting and transporting. In this study, the safety of the structure was evaluated by considering the center of gravity of the fan and the effect of the fan being tilted up. An analysis of the buckling was performed by hand calculation. Nonlinear analysis was performed using ABAQUS to evaluate the safety of the structure. The safety factor for buckling is above 4.0 and the safety factor for stress is calculated to be 1.31 under the worst load distribution conditions.

Building Information Modeling for Temporary Structure Planning and Safety Analysis (BIM을 활용한 가설물 계획 및 안전 관리)

  • Kim, Kyungki;Cho, Yong Kwon;Park, Man-Woo
    • Journal of KIBIM
    • /
    • v.6 no.2
    • /
    • pp.12-18
    • /
    • 2016
  • The entire construction safety is significantly influenced by proper uses of temporary structures. However, in current practices, temporary structures are used without sufficient planning and analysis on their impact on safety. Consequently, problems in worker safety and loss of productivity are frequently caused related to temporary structures. This paper introduces an approach that uses Building Information Modeling (BIM) to automatically create temporary structures as part of construction plans and identifies potential safety hazards related to the temporary structures. In this study, the type of temporary structure is limited to scaffolding. Automation algorithms were developed and applied to (1) analyze daily construction site conditions (2) create required scaffolding objects, and (3) identify potential safety hazards related to scaffolding. A case study using a real-world construction project demonstrated that scaffolding objects were properly created based on user-input and potential safety hazards were successfully identified without human intervention.

Characteristic Analysis of Induction Phenomena in the Nearby Mesh Structure Conductive Part of Large Capacity Wireless Power Transmission System (대용량 무선전력전송 환경 인근 메쉬구조 도전부 유도현상 특성 분석)

  • Chae, Dong-Ju;Yi, Geon-Ho;Lim, Hyun-Sung;Cho, Sung-Koo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.1
    • /
    • pp.207-214
    • /
    • 2019
  • A large-capacity wireless power system is a technology that transmits electric power of kW or more in a noncontact type. Electric cars, electric buses, and electric railways. In order to increase the power transmission efficiency, a resonance method using a frequency of kHz is applied and the efficiency is 80 ~ 90%. In this case, the loss is 10 ~ 20% other than efficiency, and corresponds to several hundreds of W to several kW in kW class wireless power transmission. 35 kW wireless feed system environment, and induced current in the nearby conductive part was measured. As a result of analysis, it was confirmed that induction phenomenon is higher as the loop configuration of the conductive part per area is dense. The increase of the induced current in the mesh loop is characterized by the density of the nearby conductive part having a permeability per unit area. The concentration of the magnetic field by the permeability is increased and the induction phenomenon causing the induction current is increased. It was confirmed that induction phenomenon increases by about 2.7 times when 9 times dense structure is formed.

Crystal Structure of the Regulatory Domain of MexT, a Transcriptional Activator of the MexEF-OprN Efflux Pump in Pseudomonas aeruginosa

  • Kim, Suhyeon;Kim, Songhee H.;Ahn, Jinsook;Jo, Inseong;Lee, Zee-Won;Choi, Sang Ho;Ha, Nam-Chul
    • Molecules and Cells
    • /
    • v.42 no.12
    • /
    • pp.850-857
    • /
    • 2019
  • The Gram-negative opportunistic pathogen, Pseudomonas aeruginosa, has multiple multidrug efflux pumps. MexT, a LysR-type transcriptional regulator, functions as a transcriptional activator of the MexEF-OprN efflux system. MexT consists of an N-terminal DNA-binding domain and a C-terminal regulatory domain (RD). Little is known regarding MexT ligands and its mechanism of activation. We elucidated the crystal structure of the MexT RD at 2.0 Å resolution. The structure comprised two protomer chains in a dimeric arrangement. MexT possessed an arginine-rich region and a hydrophobic patch lined by a variable loop, both of which are putative ligand-binding sites. The three-dimensional structure of MexT provided clues to the interacting ligand structure. A DNase I footprinting assay of full-length MexT identified two MexT-binding sequence in the mexEF-oprN promoter. Our findings enhance the understanding of the regulation of MexT-dependent activation of efflux pumps.

A Study on the Analysis of Aviation Safety Data Structure and Standard Classification (항공안전데이터 구조 분석 및 표준 분류체계에 관한 연구)

  • Kim, Jun Hwan;Lim, Jae Jin;Lee, Jang Ryong
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.28 no.4
    • /
    • pp.89-101
    • /
    • 2020
  • In order to enhance the safety of the international aviation industry, the International Civil Aviation Organization has recommended establishing an operational foundation for systematic and integrated collection, storage, analysis and sharing of aviation safety data. Accordingly, the Korea aviation industry also needs to comprehensively manage the safety data which generated and collected by various stakeholders related to aviation safety, and through this, it is necessary to previously identify and remove hazards that may cause accident. For more effective data management and utilization, a standard structure should be established to enable integrated management and sharing of safety data. Therefore, this study aims to propose the framework about how to manage and integrate the aviation safety data for big data-based aviation safety management and shared platform.

A Systematic Method for Independent Safety Assessment of Railway System by Applying NOR-STA Tool (NOR-STA 도구를 활용한 체계적 철도시스템 독립안전성 평가 방안)

  • Jung Kyou Um;Peom Park;Young Min Kim
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.19 no.1
    • /
    • pp.29-38
    • /
    • 2023
  • Independent Safety Assessment (ISA) is a third-party assessment that is to confirm that the system satisfies the safety requirements in the defined operational context. The process of this assessment often brings about many complex arguments that should be supported by evidence and justification. The communication between arguments and evidence is of the most importance in the context of safety case. This study illustrates how NOR-STA can be used for ISA process, showing the effective structure of safety compliance. The study outlines the steps to breaks down the top goal into many elements such as arguments, sub-goals, justification, context and assumptions. It concludes that the evidence-based safety conformance process utilizing NOR-STA provides a more effective and systematic representation of the independent safety assessment process in conformance cases.

Programming for the Structural Analysis of Form Structure (건축 거푸집 설계 응력산정 프로그램 개발에 관한 기초적 연구)

  • 손기상
    • Journal of the Korean Society of Safety
    • /
    • v.8 no.1
    • /
    • pp.21-28
    • /
    • 1993
  • Occupational Safety & Health Code requires to calculate Design Load and stress for the approval within thirty working days prior to initiating each construction site work This study is to develop an easy and useful program that each safety manager. Controller or engineers are able to make output for the above mentioned form structure analyses without knowledge or engineering background of it. Therefore. three, randomly selected. different major student and engineers verified if they could make output. really without the engineering background. And then some deficiencies are corrected after finding those from the program operation.

  • PDF

Review of Safety for CAM System in Mold Structure Manching (금형 구조부 가공을 위한 CAM 시스템 안정성 조사)

  • Kim, Hyung-Man;Kim, Jong-Gurl
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2006.11a
    • /
    • pp.239-254
    • /
    • 2006
  • In mold structure machining, tool interference is a phenomenon which results from a collision between a blade of tool and a workpiece. Also tool collision is a phenomenon which results from a collision of holder with the object to be machined. These phenomena not only cause damages to mold and tool but also increase machining time and cost. To detect a collision of a tool to mold structure, first of all, the mold structure and a tool must be defined with famous geometric models such CSG, B-rep, and Voxel. A tool is defined as a combination of the blade, the shank, and the holder. This thesis reviews various collision detection algorithms using z-map and computer 3D graphic collision detection algorithms for the tool in machining a mold structure.

  • PDF