• 제목/요약/키워드: Safety Step

검색결과 1,069건 처리시간 0.027초

차세대전동차 안전스텝 개발에 관한 연구 (A Study on Safety Step for Advanced Electric Multiple Unit)

  • 정의진;김길동;이기열;임봉채;박상규;이원대
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.475-480
    • /
    • 2010
  • The safety step has been developed to ensure the passengers' safety including the disabled and the weak by eliminating gap between vehicle and platform. The type of safety step is divided according to the position that the safety step is installed. The type of safety step attached platform is the rubber type that is previously attached to a platform. The installed rubber can reduces the gap between vehicle and platform by a fixed distance. If the safety step is installed on the vehicle, it is possible to respond to the various platform typed such as straight or curved form. It is also flexible to the height of riding depends on number of passenger and platform conditions and does not require crew's additional operation. We have been developed vehicle attached safety step for advanced electric multiple unit. We hope to increase the use of safety step for the disabled and the weak to expand the convenience use of railway transportation system.

  • PDF

학교안전관리사 자격의 검정기준 및 검정과목 개발 연구 (A Study on the Development of Criteria and Subjects for The School Safety Manager Qualifications)

  • 황영아
    • 한국안전학회지
    • /
    • 제32권1호
    • /
    • pp.98-107
    • /
    • 2017
  • This study is aimed to design for qualification structure and develop the subjects for examination of the school safety manager qualifications. For the study purpose, job analysis and meetings with experts were performed for extract contents such as task range, criteria of examination, subjects of examination and examination methods, etc. The first step, duties and tasks of the school safety manager were figured out through revised job analysis data of the school safety manager developed before. On the second step, job model was established and developed job specification including importance, difficulty and frequency of each task. On the third step, task specification was developed, and Knowledge-Skill Matrix was the most important thing on examination were completed. The fourth step was the selection of examination subject using task-subject matrix and 6 subjects such as The Principles of Safety, Understanding of the School Safety Manual, Law Related on the School Safety, Introduction to Education, Understanding and Dealing with Type of the School Safety, Establishment of the School Safety Plan were derived from previous procedure. The fifth step was development of guidelines for design examination of each subject. The last step was development for skills education program.

Study of Touch and Step Voltages with Grounding Grid Using Electrolytic Tank and Analysis Program

  • Gil, Hyoung-Jun;Kim, Hyang-Kon;Kill, Gyung-Suk
    • International Journal of Safety
    • /
    • 제9권2호
    • /
    • pp.1-5
    • /
    • 2010
  • In order to analyze the potential rise of ground surface of grounding grid installed in buildings, the grounding simulator has been designed and fabricated as substantial and economical measures. This paper describes the study of touch and step voltages with grounding grid where earth leakage current is injected. To assess risk voltage of grounding grid, the grounding simulator and CDEGS program were used to obtain measured data and theoretical results of this study. The grounding simulator was composed of an electrolytic tank, AC power supply, a movable potentiometer, and test grounding electrodes. The potential rise was measured by grounding simulator, and the touch and step voltages were computed by CDEGS program. As a consequence, the touch voltage and step voltage above the grounding grid were very low, but were significantly increased near the edge of grounding grid.

건설공사 발주 공공기관의 안전점검 체계구축에 관한 연구 (Establishment of a Safety Inspection System for Public Institutions Ordered Construction Projects)

  • 박응호;이수동;정기효
    • 대한안전경영과학회지
    • /
    • 제25권3호
    • /
    • pp.55-62
    • /
    • 2023
  • Public institutions have a responsibility to ensure the safety of their employees and the public. One way to do this is to implement a systematic safety inspection system based on risk assessments and continuous improvements. This study developed a systematic safety inspection system for public institutions that are ordered construction projects. The proposed system in this study consists of a three-step process: (1) developing safety grade evaluation tables, (2) preparing and conducting safety inspections, and (3) evaluating and improving safety management grades. The first step is to develop safety grade evaluation tables by analysis and diagnosis of the construction site's work type, disaster statistics, and related laws. The second step is to conduct safety inspections using the developed evaluation tables. The third step is to determine the safety management grade based on the results of the safety inspection, and to improve risk factors found during the safety evaluation. The proposed system was implemented in highway construction projects carried out by public institutions. The results showed that the proposed system has two major effects: (1) reducing accident-related deaths and injuries, (2) improving safety management levels by continuous evaluation and improvement. The proposed system can be utilized in construction projects ordered by public institutions to improve the level of occupational safety and health.

A Methodology for Establishment of Safety Culture in Industry through Global Company Practices

  • Kim, Beom Soo;Lee, Yujeong;Chang, Seong Rok
    • 대한인간공학회지
    • /
    • 제35권2호
    • /
    • pp.85-95
    • /
    • 2016
  • Objective:The purpose of this study is to suggest the methodology for establishment of safety culture in industry. Background: There have been studies indicating positive relation between safety culture and safety performance. But the areas of those efforts have been mainly focused on elements or factors consisting of safety culture. So it is expected that studies on methodologies for developing process of the culture could contribute for the industry to understand and apply it accordingly in order to improve their practices. Method: In this study, the scope was considered just for industry, even though there are many fields of culture. As the first step, the limitations of regulatory control and efforts by industry were reviewed, and the trends of researches were presented. In the second step, the global company practices were provided with detailed activities. Results: This paper showed the limitations of present state in government strategies and industry for safety culture improvement. Also the restricted areas in researches were shown. As one of the solutions to resolve those things, such global company practices as perception to safety journey, the steps of culture development, total safety philosophy, structure and elements of safety process, standards and procedures, training, and up to keys to success were suggested. Conclusion: Through this study, the development of the structure of safety process which consists of many purposeful activities has been derived to be very important. Because it will be the seeds of safety culture expressing their thinking process and behaviors. Also it is required to approach success step by step according to the achievement of each step. Application: This study can be used to develop the methodology and safety process in industry with different viewpoints for safety culture establishment.

승강장 안전발판 시스템의 내구성 평가 (Durability Evaluation of Platform Safety Step System)

  • 박민흥;곽희만;김민호
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제16권2호
    • /
    • pp.125-133
    • /
    • 2016
  • Purpose: The purpose of this study is to evaluate durability of platform safety step system in railway. Method: We performed finite element analysis & durability analysis of platform safety step system with VPD (Virtual Product Development) techniques and examined the durability standard & qualification life through the rig test during no failure test time in reliability qualification test. We continued to test 1 million cycles in KRS (Korea Railway Standard) for system's robust design performance. Result: FEM analysis results are 14.9MPa & 14.7MPa of pin-joint, pivot and durability analysis result is above 1 million cycles. we calculated theoretically no failure test time 855,000 cycles and through the 1 million cycles durability rig test in KRS standard we confirmed product quality. Conclusion: This platform safety step system was designed very safe in terms of a mechanical strength & durability.

AHP 및 Fuzzy를 이용한 제품기획단계에서의 안전성 평가 (A Safety Evaluation Method for a Product Design Planning Stage: Application of AHP and Fuzzy)

  • 박지영;조암
    • 대한인간공학회지
    • /
    • 제27권2호
    • /
    • pp.15-24
    • /
    • 2008
  • As users increasingly recognize the importance of safety and the Product Liability comes into effect, a company should take responsibility of protecting the users who use its product. In order to produce a safe product and satisfy the needs of users, it is critical for develope opriately and understand the characteristics of the product accurately. Furthermore, a safe product can be realized by considering a safety level of the product in a whole product development process. However, in general, product development projects hardly evaluate the safety of a product in the product planning step. In addition, most of safety evaluation methods which are applied in the product planning step have a tendency to be qualitative because a detailed product design step. Therefore, this research aims at enhancing the performance of the safety evaluation process by applying quantitative methods such as 'AHP' and 'Fuzzy'. AHP can help analysts derive the weight of safety factors. Fuzzy is applied to evaluate the degree of safety of product elements in this paper. The proposed method will be able to improve the safety level of a product by using the quantitative methods in the product planning step.

접지시스템의 접촉전압 및 보폭전압 측정오차 감소 기법에 관한 연구 (Study on Measurement Error Reduction Technique when Measuring Touch and Step Voltage of Grounding System)

  • 김동우;임용배;이상익;최명일;문현욱
    • 전기학회논문지
    • /
    • 제64권1호
    • /
    • pp.188-195
    • /
    • 2015
  • This paper presents measurement error reduction technique of touch and step voltage of grounding system based on numerical analysis. When measuring touch and step voltage of grounding system, auxiliary current probes should be located at suitable places. However, the auxiliary probes can not be located at suitable places in such cases as there are buildings and pavements. Therefore, in this paper, we provided measurement error reduction technique of touch and step voltage of grounding system according to the positions of auxiliary probes and angle between auxiliary probes. Also, measurement error analyses of touch and step voltage of grounding system have been conducted using more than one current probe. Based on these analyses, recommended positions of auxiliary probes within allowable measurement errors were presented.

의료용 Cyclotron의 방사선안전관리 행위 예측모형 (A Prediction Model for the Radiation Safety Management Behavior of Medical Cyclotrons)

  • 정지혜;한은옥;김쌍태
    • Journal of Radiation Protection and Research
    • /
    • 제33권2호
    • /
    • pp.77-86
    • /
    • 2008
  • 방사성동위원소(RadioIsotope) 생산시설인 Cyclotron의 방사선안전관리는 방사선작업종사자뿐만 아니라 일반 이용자들의 방사선에 의한 건강장해를 예방하기 위해 중요한 부분이므로 방사선안전관리 행위에 영향을 미치는 예측모형을 도출하여 방사선안전관리 행위수준을 높이는데 필요한 근거자료를 제공하고자 하였다. 문헌고찰, 현장관찰, 전문가 포커스 토의를 통하여 도출되고 내용타당도가 확보된 설문지를 사용하여 국내 Cyclotron이 설치된 24개 허가기관의 방사선안전관리자를 대상으로 2008년 1월 2일부터 30일간 조사하여 다음과 같은 결과를 도출하였다. 방사선안전관리에 관한 경로는 1단계 생산준비, 2단계 RI생산, 3단계 합성, 4단계 분배, 5단계 품질관리, 6단계 운반용기 포장, 7단계 운반 단계로 지정하였다. 방사선피폭의 우려가 가장 높다고 생각하는 단계는 분배 15명(62.5%), 시설 설치부터 운영까지 가장 힘든 업무는 인허가 관련'과 설치시설 및 생산장비확보'가 각 9명(37.5%), 방사선피폭 관련 문제가 발생한 단계는 '합성과 분배'각 4번(30.8%)으로 높게 나타났다. 방사선안전관리 행위수준은 4점 만점을 기준으로 최소 2.42점, 최고 4.00점, 평균 $3.46{\pm}0.47$점으로 나타났다. 방사선안전관리 행위와 직업에 대한 복지후생(r=0.529)이 유의수준 5%에서 통계적으로 유의한 상관관계가 있는 것으로 나타났다. 방사선안전관리 행위에 영향을 미치는 변수를 기준으로 예측모델을 도출한 결과 일반적 특성, 기관 특성, 자기효능감은 통계적으로 유의한 경로를 나타내지 않았고 직업특성 중 복지후생이 방사선안전관리 행위에 영향을 미치는 것으로 나타났다. 따라서 방사선안전관리 행위수준을 높이기 위해 직업적 특성 중 복지후생 수준을 향상시킬 수 있는 전략이 필요하다고 본다. 본 연구는 최근 설치가 급격히 증가하는 Cyclotron의 방사선안전관리에 대한 국내 전수조사로 최초 수행하여 기초자료를 제공하는데 의미가 있다고 본다.

RULA 평가기법을 활용한 분말소화기 디자인 연구 (A Study on Powder Fire Extinguisher Design with RULA Technique Used)

  • 강채우;김덕남
    • 한국안전학회지
    • /
    • 제32권2호
    • /
    • pp.117-123
    • /
    • 2017
  • This study was intended to find methods of fire extinguishing system designs that can improve the equipment's usability. In this study, the fire suppression experiment through fire extinguishers and the data drawn through the experiment were analyzed, and then the guideline for the improvement of designs was presented. The procedure is as follows. A fire suppression experiment with the use of fire extinguishers was done by 43 average adults. The whole process of the fire suppression was videotaped, and then captured major scenes were analyzed with the use of RULA, a human engineering measurement tool. The analyzed data were divided into 4 steps, and then the guideline for design improvement was presented. The summary of the study is as follows. Step 1, Fire extinguisher distance step. To reduce overload occurring at the process of holding fire extinguishers suddenly, wheels are attached to the body of extinguishers, or pedestals are installed. Step 2, Fire extinguisher transportation step. The length of hose is extended, or fire fighting water is sprayed far, so that overload of legs occurring at the process of travel can be reduced. In addition, the weight of fire extinguisher shouldn't be over 2 kg. Step 3, Safety pin removal stage. Safety pins should be applied with button type, so that excessive posture of lower limbs and excessive twisting of wrists won't happen during safety pin removal process. Besides, safety pins should be designed for easy identification and operation. Step 4, Fire extinguishing agent spraying step. To reduce overload occurring at sudden spraying of fire fighting water, pressure should be increased gradually until high pressure. With the above study results applied to existing fire extinguisher design, it may contribute to reducing any fire damage.