• 제목/요약/키워드: Safe evacuation system

검색결과 58건 처리시간 0.022초

Development of VR Fire-extinguishing Experience Education Contents Using UX Design Methodology (UX 디자인 방법론을 적용한 VR 소방체험 교육콘텐츠 개발)

  • Chung, Yoo-Kyung
    • The Journal of the Korea Contents Association
    • /
    • 제17권3호
    • /
    • pp.222-230
    • /
    • 2017
  • The Ministry of Public Safety and Security plans to expand fire safety education infrastructure to provide customized fire safety education, spread fire safety culture and develop a tailored fire safety education system as a part of the 2016 Citizens' Safety Improvement Policy. This study has also been designed to improve safety problems in the Republic of Korea. Even though safety education has been given, citizens aren't still able to experience a close-to-real situation. In addition, their understanding and satisfaction with the curriculum are very low. Therefore, this study offers VR fire-extinguishing experience education contents as an effective alternative. With a goal of having the participants experience fire extinguishing and evacuation drill in a virtual space, this program has the following advantages: i) safe fire-extinguishing experience; ii) UI to create fun ; iii) useful in fire-extinguishing education; iv) budget saving. we configure the VR fire experience system structure and hardware by applying UX design methodology. We also develop for VR-specific motion recognition plug-in and controller that can be feeling in HMD environment.

Experimental Study on the Determination of Critical Velocity for the Case of Fire in Long Traffic Tunnels (장대 교통터널 화재시 임계속도 결정에 관한 실험적 연구)

  • Yoon Chanhoon;Yoon Sungwook;Yoo Yongho;Kim Jin
    • Tunnel and Underground Space
    • /
    • 제16권1호
    • /
    • pp.85-94
    • /
    • 2006
  • In this study, scaled model tests were carried out to decide the optimal critical velocity, to prevent back layering in the case of fire in a long traffic tunnel. Realistic estimates were made for the time required for people to escape ken the tunnel and far the time required by the ventilation operator to increase the system speed to full capacity. The analysis, predicts that the emergency ventilation will start about 240 seconds after the tunnel fire. It was also found that prevention of back layering would occur within 4 minutes after fan operation. To find out optimal critical velocity, a 1/50 scaled model tunnel(diameter : 0.2 m and length : 20 m) based on the Froude similarity technique was constructed. Changing $\beta$ values in the Tetzner's equation, smoke propagation was observed. From the experiment, it was concluded that using a $\beta$ value of 0.5 to prevent back layering successfully allowed time for safe evacuation.

A Study on the Development of GIS-based Complex Simulation Prototype for Reducing the Damage of Chemical Accidents (화학사고 피해저감을 위한 GIS 연계 복합시뮬레이션 프로토타입 개발에 관한 연구)

  • Kim, Eun-Byul;Oh, Joo-Yeon;Lee, Tae Wook;Oh, Won Kyu;Kim, Hyun-Joo;Lim, Dong-yun
    • Korean Journal of Remote Sensing
    • /
    • 제36권5_4호
    • /
    • pp.1255-1266
    • /
    • 2020
  • In this study, a complex simulation prototype was developed for rapid and accurate prediction of chemical dispersion range in order to reduce human casualties caused by chemical accidents. Complex simulation considered the leakage momentum during the near-field dispersion to take into account the leakage characteristics of the chemical. In the far-distance dispersion process, the wind distribution of the existing model, which was presented uniformly, was improved using weather and topographical information around the accident site, to realize a wind field similar to the actual one. Finally, the damage range was more precise than the existing model in line with the improved near- and far-distance dispersion process. Based on the results of damage range prediction of the complex simulation, it is expected that it will be highly utilized as a system to support policy decision-making such as evacuation and return of residents after a chemical accident.

Study of the Problems and Improvements of the Installation and Maintenance for Natural Smoke Ventilators in Buildings (국내 배연창 설치 및 유지관리의 문제점과 개선방안에 관한 연구)

  • Yun, Hi-Won;Choi, Seung-Hyuck;Ryu, Hyung-Kyou
    • Fire Science and Engineering
    • /
    • 제30권6호
    • /
    • pp.118-123
    • /
    • 2016
  • In the event of a building fire, it is important to control the smoke generated to ensure the safe evacuation of occupants. A natural smoke ventilator should be installed to exhaust the fire smoke in accordance with the Korean building Act and Code. On the other hand, the present law does not specify the contents regarding natural smoke ventilators sufficiently. The problems that occur in various parts, such as the installation target, installation location, free area, and the control and maintenance of natural smoke ventilators need to be solved. In this study, the problem of the current system was examined through domestic and foreign standards, preliminary research, and field investigations. In addition, suggestions for improvement are provided.

The Study of a Correlation between Heat Release and Smoke Production by Using Oxygen Consumption Calorimeter Up to 10 MW Facility (10MW급 까지의 산소소모율법 칼로리미터를 활용한 열방출률과 연기발생률의 상관성에 관한 연구)

  • Ryu, Sang-Hoon;Yoo, Yong-Ho;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • 제24권3호
    • /
    • pp.58-65
    • /
    • 2010
  • The fire accidents having recently occurred are getting more and more larger and causing lots of damage in terms of property loss and casualties increase, so there is in need of technical fire safety development like comprehensive prevention solution in order to effectively prevent. Especially, the needing of new paradigm for advanced fire safe technology is gathering strength in high-rise modern building construction. Therefore, we want to find out on this paper what is a correlation between heat release rate measurement and smoke release volume by three parts of oxygen consumption calorimeter in bench scale calorimeter (cone calorimeter/ISO 5660/Avg.500Kw), Medium scale calorimeter (Room corner tester, Single burning Item/ISO 9750, EN 13823/Avg.3MW), and large scale calorimeter (Industry calorimeter/Avg. 10MW). Thus, Smoke detective of new paradigm devised by making use of a correlation between heat release and smoke production is to help reduce loss property and casualties. Ultimately, based on this theory, a new concept of fire alarm and evacuation system will be developed and expected to apply to a skyscraper.

A Study on Countermeasures between Central and Local Governments for Earthquake Disaster Management of Pohang, Korea (우리나라 포항지진 재난관리에 대한 중앙·지방정부 간 대책 방안 연구)

  • La, Hong Woo
    • Journal of Korean Society of Disaster and Security
    • /
    • 제12권3호
    • /
    • pp.25-34
    • /
    • 2019
  • Modern disasters prevent accidents in advance and recover after accidents are very important. Our government's current response to these accidents is not appropriate. As for disaster management so far, it has been the center of disaster response and recovery efforts, and has been led by the government against it. The reality is that most private organizations and agencies have only subsidized government disaster management agencies. Korea is no longer a safe zone for earthquakes. Now for the establishment of effective disaster management system for earthquakes in the diagnosis is very urgent and the problems of the operational disaster management, which the problems of the nation.Policies to improve academic efforts to seek alternative proposal is also at a time when volume can be said to be very big need to mine. This study from 2016 to 2019, about the earthquake that took place between National Statistical Office, based on analysis of data to. First of all, research 1: What was the government's plan on Pohang earthquake? The results showed that the residents' evacuation of Pohang was important in the Pohang earthquake, but for the sake of students' safety, they were directly assigned to the test site to cope with the emergency situation. Therefore, the research and analysis shows that the nation should continue to think about the causes and responses of the damage at the disaster site and strive to develop technologies and methods to minimize the damage.

A study on the smoke control performance of the damper exhaust system at FCEV fire in tunnel for small vehicles (소형차 전용터널 내 수소연료전지차 화재시 집중배기방식의 제연성능에 관한 연구)

  • Hong, Seo-Hee;Baek, Doo-San
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • 제24권6호
    • /
    • pp.745-756
    • /
    • 2022
  • The road tunnel is a semi-closed space that is blocked on all sides except the entrance and exit, and in the event of a fire, the smoke of the fire spreads longitudinally due to heat buoyancy caused by the fire and air currents that always exist in the tunnel. To solve this problem, smoke removal facilities are installed in road tunnels to secure a safe evacuation environment by controlling the direction of movement of smoke or directly smoking at fire points. In urban areas, the service level of urban roads decreases due to the increase in traffic due to the increase in population, and as a solution, the construction of underground roads in urban areas is increasing. When a fire occurs during hydrogen leakage through TPRD of a hydrogen fuel cell vehicle (FCEV), the fire intensity depends on the amount of leakage, and the maximum fire intensity depends on the orifice diameter of the TPRD. Considering the TPRD orifice diameter of 1.8 mm, this study analyzed the diffusion distance of fire smoke according to the wind speed of the roadway and the opening interval of the large exhaust port when the maximum fire intensity was 15 MW. As a result, it was analyzed that air flow in the tunnel could be controlled if the wind speed of the road in the tunnel was less than 1.25 m/s, and smoke could be controlled within 200 m from the fire if the damper interval was 50 m and 100 m.

Evaluation of Lateral Load Resistance and Heating/Cooling/Lighting Energy Performance of a Post-disaster Refugees Housing Using Lightweight composite Panels (경량 복합패널을 활용한 구호주거의 횡하중 저항성능 및 냉난방조명 에너지성능 평가)

  • Hwang, Moon-Young;Lee, Byung-Yun;Kang, Su-Min;Kim, Sung-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제20권3호
    • /
    • pp.252-262
    • /
    • 2019
  • Following the earthquake in Gyeongju (2016) and Pohang (2017), South Korea is no longer a safe place for earthquakes. Accordingly, the need for shelters suitable for disaster environments is increasing. In this study, a lightweight composite panel was used to produce post-disaster housing for refugees to compensate for the disadvantages of existing evacuation facilities. For this purpose, an evaluation of structural performance and thermal environment for post-disaster housing for refugees composed of lightweight composite panels was performed. To assess the structural performance, a lateral loading test was conducted on a system made of lightweight composite panels. The specimens consisted of two types, which differed according to the bonding method, as a variable. In addition, the seismic and wind loads were calculated in accordance with KBC 2016 and compared with the experimental results. Regarding the energy performance, optimization of south-facing window planning and window-wall ratio and solar heat gain coefficient were analyzed to minimize heating, cooling, and lighting energy. As a result, the specimens composed of lightweight composite panels will perform sufficiently safely for lateral loads and the optimized window planning will lead to a low-energy operation.