• Title/Summary/Keyword: SV

Search Result 1,091, Processing Time 0.033 seconds

Conversion coefficients for the estimation of effective dose in cone-beam CT

  • Kim, Dong-Soo;Rashsuren, Oyuntugs;Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.44 no.1
    • /
    • pp.21-29
    • /
    • 2014
  • Purpose: To determine the conversion coefficients (CCs) from the dose-area product (DAP) value to effective dose in cone-beam CT. Materials and Methods: A CBCT scanner with four fields of view (FOV) was used. Using two exposure settings of the adult standard and low dose exposure, DAP values were measured with a DAP meter in C mode ($200mm{\times}179mm$), P mode ($154mm{\times}154mm$), I mode ($102mm{\times}102mm$), and D mode ($51mm{\times}51mm$). The effective doses were also investigated at each mode using an adult male head and neck phantom and thermoluminescent chips. Linear regressive analysis of the DAP and effective dose values was used to calculate the CCs for each CBCT examination. Results: For the C mode, the P mode at the maxilla, and the P mode at the mandible, the CCs were 0.049 ${\mu}Sv/mGycm^2$, 0.067 ${\mu}Sv/mGycm^2$, and 0.064 ${\mu}Sv/mGycm^2$, respectively. For the I mode, the CCs at the maxilla and mandible were 0.076 ${\mu}Sv/mGycm^2$ and 0.095 ${\mu}Sv/mGycm^2$, respectively. For the D mode at the maxillary incisors, molars, and mandibular molars, the CCs were 0.038 ${\mu}Sv/mGycm^2$, 0.041 ${\mu}Sv/mGycm^2$, and 0.146 ${\mu}Sv/mGycm^2$, respectively. Conclusion: The CCs in one CBCT device with fixed 80 kV ranged from 0.038 ${\mu}Sv/mGycm^2$ to 0.146 ${\mu}Sv/mGycm^2$ according to the imaging modes and irradiated region and were highest for the D mode at the mandibular molar.

Evaluation of Influence of Anesthetics on Canine Stroke Volume and Feasibility of ACT Using Echocardiography (개에서 심초음파 검사시 마취제가 일회심박출량에 미치는 영향과 ACT법의 적용가능성 평가)

  • Park, Ki-Tae;Lee, Eun-Sung;Jung, Dong-In;Yeon, Seong-Chan;Lee, Hee-Chun
    • Journal of Veterinary Clinics
    • /
    • v.30 no.4
    • /
    • pp.264-267
    • /
    • 2013
  • Stroke volume (SV) is an important parameter for monitoring of a critically ill animal and is echocardiographically measured using the modified Simpson's method, automated contour tracking (ACT) method and left ventricular outflow method. The purpose of this study was to evaluate the effect of anesthesia (isoflurane) on the SV during echocardiographic examination and to evaluate the feasibility of ACT method for measuring the stroke volume without anesthesia (conscious state). Ten clinically healthy adult Beagle dogs (3 male and 7 female, weighing 6.6-10.8 kg, aged 2-3 years old) were enrolled. Our study found that the dogs anesthetized have a significantly lower SV, compared to the SV of dogs unanesthetized, regardless of methods measuring SV. In addition, in the dogs without anesthesia, the SV measured by ACT method was significantly lower than the other two methods. This result implies that the anesthesia may significantly lower the SV. Thus, the measurement of SV under anesthesia may not be adequate in veterinary field. Furthermore because the ACT method measured SV significantly lower than other two methods, this method may be inappropriate for measuring SV in even conscious dogs.

Finger Doses Received during $^{99m}Tc$ Injections Calculated with GEANT4 (GEANT4를 이용한 $^{99m}Tc$ 주입시 손가락 선량계산)

  • Han, Dong-Hyun;Kang, Sang-Koo;Kim, Chong-Yeal
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.1
    • /
    • pp.41-46
    • /
    • 2008
  • To estimate the finger dose absorbed by $^{99m}Tc$ injection, simulations are carried out to calculate the dose equivalent of each finger per second with radioactivity of 370 MBq, based on the GEANT4 simulator. For the $^{99m}Tc$ source of the volume of 0.4mL and the radioactivity of 370 MBq, we obtained the dose equivalent of the right thumb ($0.29\;{\mu}Sv{\cdot}sec^{-1}$), the right index finger ($1.19\;{\mu}Sv{\cdot}sec^{-1}$), the right middle finger ($1.07\;{\mu}Sv{\cdot}sec^{-1}$), the left thumb ($4.36\;{\mu}Sv{\cdot}sec^{-1}$), and the left index finger ($3.37\;{\mu}Sv{\cdot}sec^{-1}$), respectively. This simulation results may serve as a useful data in the prediction of finger dose absorbed by $^{99m}Tc$ injection.

Assessment of Effective Dose for General Radiography of Adults Based on Diagnostic Reference Level(DRL) by Using PCXMC Program (진단참고준위(DRL)를 기준으로 PCXMC 프로그램을 이용한 성인의 일반촬영 부위별 유효선량 평가)

  • Jeong, Hee-Cheol;Lee, SamYol
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.807-812
    • /
    • 2018
  • In this study, we investigated the conditions used in setting the recommendation level of general radiography diagnostic reference and tried to evaluate the effective dose and biological evaluation using PCXMC v2.0 program. As a result based on the effective dose of male in ICRP 60, the highest Pelvis AP was 0.794 mSv. The lowest Chest PA was 0.050 mSv. In the case of ICRP 103, the highest T-Spine AP was 0.906 mSv The lowest Chest PA was 0.052 mSv. For 40 years old male and female adults, effective doses of general radiography were evaluated and even if the medical exposures are not subject to the limit of dose, efforts should be made to reduce the medical exposures of the people by keeping the dose below the recommended amount in order to minimize the probable effect of radiation hazard.

Hidden Markov model with stochastic volatility for estimating bitcoin price volatility (확률적 변동성을 가진 은닉마르코프 모형을 통한 비트코인 가격의 변동성 추정)

  • Tae Hyun Kang;Beom Seuk Hwang
    • The Korean Journal of Applied Statistics
    • /
    • v.36 no.1
    • /
    • pp.85-100
    • /
    • 2023
  • The stochastic volatility (SV) model is one of the main methods of modeling time-varying volatility. In particular, SV model is actively used in estimation and prediction of financial market volatility and option pricing. This paper attempts to model the time-varying volatility of the bitcoin market price using SV model. Hidden Markov model (HMM) is combined with the SV model to capture characteristics of regime switching of the market. The HMM is useful for recognizing patterns of time series to divide the regime of market volatility. This study estimated the volatility of bitcoin by using data from Upbit, a cryptocurrency trading site, and analyzed it by dividing the volatility regime of the market to improve the performance of the SV model. The MCMC technique is used to estimate the parameters of the SV model, and the performance of the model is verified through evaluation criteria such as MAPE and MSE.

Dose analysis of nearby residents and workers due to the emission accident of gaseous radioactive material at the spent resin mixture treatment facility

  • Jaehoon Byun;Seungbin Yoon;Hee Reyoung Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4543-4553
    • /
    • 2023
  • The dose from a possible accident at a microwave-based spent resin mixture treatment facility that was to be installed and operated at the Wolsong nuclear power plant was analyzed to evaluate the radiological safety prior to its installation and operation. The dose to which workers and nearby residents are likely to be exposed was calculated based on the atmospheric dispersion and deposition factors using the XOQDOQ code. The highest atmospheric dispersion factors were 1.349E-05 s/m3 (workers) and 1.534E-06 s/m3 (residents). The highest doses due to emissions from the mock-up tank before operation were 1.91E-06 mSv (workers) and 1.78E-07 mSv (residents). Even after 3 h of operation, emissions from the mock-up tank had the greatest impact ranging from 4.63E-08 to 1.24E-06 mSv (workers) and 2.74E-10 to 1.16E-07 mSv (residents), respectively. The doses were 7.09E-09-4.55E-07 mSv and 4.18E-11-4.25E-08 mSv at 4-5 h of operation, and the maximum doses after operation reached 5.69E-07 mSv and 5.31E-08 mSv for the workers and residents, respectively. Even at the exclusion area boundary (EAB), 4.76E-08-9.51E-07 mSv (annual dose:9.52E-05–1.90E-03 mSv/y) was below the dose limit of the EAB, and the safety of the facility installation inside the NPP was confirmed.

Evaluation of Radiation Exposure to Nurse on Nuclear Medicine Examination by Use Radioisotope (방사성 동위원소를 이용한 핵의학과 검사에서 병동 간호사의 방사선 피폭선량 평가)

  • Jeong, Jae Hoon;Lee, Chung Wun;You, Yeon Wook;Seo, Yeong Deok;Choi, Ho Yong;Kim, Yun Cheol;Kim, Yong Geun;Won, Woo Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.44-49
    • /
    • 2017
  • Purpose Radiation exposure management has been strictly regulated for the radiation workers, but there are only a few studies on potential risk of radiation exposure to non-radiation workers, especially nurses in a general ward. The present study aimed to estimate the exact total exposure of the nurse in a general ward by close contact with the patient undergoing nuclear medicine examinations. Materials and Methods Radiation exposure rate was determined by using thermoluminescent dosimeter (TLD) and optical simulated luminescence (OSL) in 14 nurses in a general ward from October 2015 to June 2016. External radiation rate was measured immediately after injection and examination at skin surface, and 50 cm and 1 m distance from 50 patients (PET/CT 20 pts; Bone scan 20 pts; Myocardial SPECT 10 pts). After measurement, effective half-life, and total radiation exposure expected in nurses were calculated. Then, expected total exposure was compared with total exposures actually measured in nurses by TLD and OSL. Results Mean and maximum amount of radiation exposure of 14 nurses in a general ward were 0.01 and 0.02 mSv, respectively in each measuring period. External radiation rate after injection at skin surface, 0.5 m and 1 m distance from patients was as following; $376.0{\pm}25.2$, $88.1{\pm}8.2$ and $29.0{\pm}5.8{\mu}Sv/hr$, respectively in PET/CT; $206.7{\pm}56.6$, $23.1{\pm}4.4$ and $10.1{\pm}1.4{\mu}Sv/hr$, respectively in bone scan; $22.5{\pm}2.6$, $2.4{\pm}0.7$ and $0.9{\pm}0.2{\mu}Sv/hr$, respectively in myocardial SPECT. After examination, external radiation rate at skin surface, 0.5 m and 1 m distance from patients was decreased as following; $165.3{\pm}22.1$, $38.7{\pm}5.9$ and $12.4{\pm}2.5{\mu}Sv/hr$, respectively in PET/CT; $32.1{\pm}8.7$, $6.2{\pm}1.1$, $2.8{\pm}0.6$, respectively in bone scan; $14.0{\pm}1.2$, $2.1{\pm}0.3$, $0.8{\pm}0.2{\mu}Sv/hr$, respectively in myocardial SPECT. Based upon the results, an effective half-life was calculated, and at 30 minutes after examination the time to reach normal dose limit in 'Nuclear Safety Act' was calculated conservatively without considering a half-life. In oder of distance (at skin surface, 0.5 m and 1 m distance from patients), it was 7.9, 34.1 and 106.8 hr, respectively in PET/CT; 40.4, 199.5 and 451.1 hr, respectively in bone scan, 62.5, 519.3 and 1313.6 hr, respectively in myocardial SPECT. Conclusion Radiation exposure rate may differ slightly depending on the work process and the environment in a general ward. Exposure rate was measured at step in the general examination procedure and it made our results more reliable. Our results clearly showed that total amount of radiation exposure caused by residual radioactive isotope in the patient body was neglectable, even comparing with the natural radiation exposure. In conclusion, nurses in a general ward were much less exposed than the normal dose limit, and the effects of exposure by contacting patients undergoing nuclear medicine examination was ignorable.

  • PDF

Magnetoresistance of Single-type and Dual-type GMR-SV Multilayer Thin Films with Top and Bottom IrMn Layer (상부와 하부 IrMn층을 갖는 단일구조 및 이중구조 거대자기저항-스핀밸브 다층박막의 자기적 특성 비교 분석)

  • Choi, Jong-Gu;Kim, Su-Hee;Choi, Sang-Heon;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.27 no.4
    • /
    • pp.115-122
    • /
    • 2017
  • The antiferromagnet IrMn based four different GMR-SV multilayers on Corning glass were prepared by using ion beam deposition and DC magnetron sputtering system. The magnetoresistance (MR) properties for single-type and dual-type GMR-SV multilayer films were investigated through the measured major and minor MR curves. The exchange bias coupling field ($H_{ex}$) and coercivity ($H_c$) of pinned layer, the $H_c$ and interlayer exchange coupling field ($H_{int}$) of free layer for the dual-type structure GMR-SV multilayer films consisted of top IrMn layer were 410 Oe, 60 Oe, 1.6 Oe, and 7.0 Oe, respectively. The minor MR curve of two free layers was performed the squarelike feature having a MR ratio of 8.7 % as the sum of 3.7 % and 5.0 %. The value of average magnetic field sensitivity (MS) was maintained at 2.0 %/Oe. Also, the magnetoresistance properties of the single-type and dual-type structure GMR-SV multilayer films consisted of bottom IrMn layer were decreased more than those of top IrMn layer. Two antiparallel states of magnetization spin arrays of the pinned and free layers in the dual-type GMR-SV multilayer films occurred the maximum MR value by the effect of spin dependence scattering.

Inhibition of SV40 DNA replication in simian cell by bacteriophage M13 DNA sequences (원숭이 신장 세포에서 M13 DNA에 의한 SV40 DNA 복제 억제 현상에 대하여)

  • 김연수;구용의;강현삼
    • Korean Journal of Microbiology
    • /
    • v.26 no.3
    • /
    • pp.162-166
    • /
    • 1988
  • Bacteriophage M13 DNAs carrying the wild type or base substituted SV40 DNA replication origins were used for replication assay. In vivo and in vitro assay with African green monkey cell line COS-1 showed that the replication of M13-SV40 recombinant DNAs was restricted like a pBR322 SV40 recombinant DNA(Lusky and Botchan, 1981). Furthermore, recombinant phage DNAs isolated from the transfected siminan cells subsequently show a reduced ability to retransform E. coli. But pATSV-W(Kim et al., 1988) was replicated in COS-1 cells normally. We think that a poison sequence may exist on bacteriophage M13 DNA like pBR322.

  • PDF

Impact of SV40 T antigen on two multiple fission microalgae species Scenedesmus quadricauda and Chlorella vulgaris

  • Gomaa, Ahmed E.;Yang, Seung Hwan
    • International journal of advanced smart convergence
    • /
    • v.7 no.1
    • /
    • pp.48-63
    • /
    • 2018
  • The combination of Simian Virus40 (SV40)'s large T antigen with its replication origin is commonly used in molecular studies to enhance the expression of heterogeneous genes through multiplying the plasmid copy number. There are no reports related to the impact of the SV40 T antigen on plant, multiple fissional, cell-type. This study explores the response of two multiple-fission microalgal cells, Scenedesmus quadricauda and Chlorella vulgaris, to the expression of the T-antigen, with aim of applying SV40 T-antigen to increase the expression efficiency of foreign genes in the two species. Different levels of low-expression have been constructed to control the expression of SV40 T antigen using three heterogenous promoters (NOS, CaMV35S, and CMV). Chlorella cultures showed slowdown in the growth rate for samples harboring the T antigen under the control of CaMV35S and CMV promoters, unlike Scenedesmus cultures which showed no significant difference between samples and could have silenced the expression.