To estimate the finger dose absorbed by $^{99m}Tc$ injection, simulations are carried out to calculate the dose equivalent of each finger per second with radioactivity of 370 MBq, based on the GEANT4 simulator. For the $^{99m}Tc$ source of the volume of 0.4mL and the radioactivity of 370 MBq, we obtained the dose equivalent of the right thumb ($0.29\;{\mu}Sv{\cdot}sec^{-1}$), the right index finger ($1.19\;{\mu}Sv{\cdot}sec^{-1}$), the right middle finger ($1.07\;{\mu}Sv{\cdot}sec^{-1}$), the left thumb ($4.36\;{\mu}Sv{\cdot}sec^{-1}$), and the left index finger ($3.37\;{\mu}Sv{\cdot}sec^{-1}$), respectively. This simulation results may serve as a useful data in the prediction of finger dose absorbed by $^{99m}Tc$ injection.
[ $^{99m}Tc$ ]를 주사할 때 시술자의 손가락에 흡수되는 방사선량을 예측하기 위해, GEANT4를 이용하여 초당 370 MBq의 방사능량을 가지는 0.4 mL 체적의 $^{99m}Tc$ 선원을 대상으로 각 손가락에 대한 등가선량을 구하였다. 시뮬레이션 결과, 오른손 엄지($0.29\;{\mu}Sv{\cdot}sec^{-1}$), 검지($1.19\;{\mu}Sv{\cdot}sec^{-1}$), 중지($1.07\;{\mu}Sv{\cdot}sec^{-1}$), 왼손 엄지($4.36\;{\mu}Sv{\cdot}sec^{-1}$), 검지($3.37\;{\mu}Sv{\cdot}sec^{-1}$)의 등가선량을 얻을 수 있었다. 이와 같은 계산 결과는 $^{99m}$Tc 주입시 시술자의 손가락에 흡수되는 선량을 예측할 수 있는 유용한 기초자료로 활용될 수 있을 것이다.