• Title/Summary/Keyword: SUV (Standardized Uptake Value)

Search Result 66, Processing Time 0.029 seconds

Study on the Difference of Standardized Uptake Value in Fusion Image of Nuclear Medicine (핵의학 융합영상의 표준섭취계수 차이에 관한 연구)

  • Kim, Jung-Soo;Park, Chan-Rok
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.553-560
    • /
    • 2018
  • PET-CT and PET-MRI which integrates CT using ionized radiation and MRI using phenomena of magnetic resonance are determined to have the limitation to apply the semi-quantitative index, standardized uptake value (SUV), with the same level due to the fundamental differences of image capturing principle and reorganization, hence, their correlations were analyzed to provide their clinical information. To 30 study subjects maintaining pre-treatment, $^{18}F-FDG$ (5.18 MBq/㎏) was injected and they were scanned continuously without delaying time using $Biograph^{TM}$ mMR 3T (Siemens, Munich) and Biograph mCT 64 (Siemens, Germany), which is an integral type, under the optimized condition except the structural differences of both scanners. Upon the measurement results of $SUV_{max}$ setting volume region of interest with evenly distributed radioactive pharmaceuticals by captured images, $SUV_{max}$ mean values of PET-CT and PET-MRI were $2.94{\pm}0.55$ and $2.45{\pm}0.52$, respectively, and the value of PET-MRI was measured lower by $-20.85{\pm}7.26%$ than that of PET-CT. Also, there was a statistically significant difference in SUVs between two scanners (P<0.001), hence, SUV of PET-CT and PET-MRI cannot express the clinical meanings in the same level. Therefore, in case of the patients who undergo cross follow-up tests with PET-CT and PET-MRI, diagnostic information should be analyzed considering the conditions of SUV differences in both scanners.

Effect of Extended Field of View on Measurements of Standardized Uptake Value in PET/CT (PET/CT검사에서 CT의 확대 유효시야 적용이 표준화섭취계수에 미치는 영향)

  • Park, Soon-Ki;Nam, Ki-Pyo;Kim, Kyeong-Sik;Shin, Sang-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.82-85
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the effect of extended CT field of view (FOV) on PET/CT of Standardized uptake value (SUV) when imaging extends beyond the CT FOV. Materials and Methods: CT images were reconstructed at different FOV sizes (500 and 700 mm). Two sets of CT images were reconstructed from the CT projection data by using two FOV sizes. Twenty patients were used in this study. PET images were reconstructed using attenuation maps with 500 mm CT FOV and 700 mm extended CT FOV images. Region of interests (ROIs) drawn on the PET images. In addition, twenty patients' PET images reconstructed by 500 mm CT FOV and 700 mm extended CT FOV were compared with $SUV_{max}$. Results: When using attenuation maps with 700 mm extended CT FOV, the $SUV_{max}$ analysis of liver (p=0.000), lung (p=0.007), mediastinum (p=0.001) were statistically significant. Conclusions: 700 mm extended CT FOV helps to recover the true activity distribution in the PET emission data. In addition, 700 mm extended CT FOV has affected SUV measurement of liver, lung, mediastinum.

  • PDF

Prediction of Prognosis to Concurrent Chemo-Radiotherapy by Standardized Uptake Value of $2-[18^F]$ Fluovo-2-Deoxy-D-Glucose for Nasopharyngeal Carcinomas (비인강암 환자의 예후에서 $2-[18^F]$ Fluoro-2-Deoxy-D-Glucose PET 영상에서 계산되는 Standardized Uptake Value의 의의)

  • Lee Sang-wook;Im Ki Chun;Nam Soon Yuhl;Kim Jae Seung;Choi Eun Kyung;Ahn Seung Do;Shin Seong Soo;Ryu Jin Sook;Kim Sang Yoon;Lee Bong-Jae;Choi Seung-Ho;Kim Sung-Bae;Moon Dae Hyuk
    • Radiation Oncology Journal
    • /
    • v.23 no.1
    • /
    • pp.9-16
    • /
    • 2005
  • Purpose : To prospectively evaluate the use of positron emission tomography with the glucose analog fluoro-deoxyglucose (FDG-PET) to deoxyglucose (FDG-PET) to predict disease-free survival (DFS) after concurrent chemo-radiotherapy (CCRT) in patients with non-disseminated nasopharyngeal carcinoma (NPC). Materials and Methods : We studied 41 patients with non-disseminated NPC scheduled to undergo platinum-based CCRT were eligible for this study. Patients were studied by FDG-PET prior to the CCRT. FDG uptake of tumors were measured with the maximal standardized uptake value (SUV). Results : Complete response rate was $100\%$. In ten patients who presented with any component of treatment failure, the median $SUV_{max}$ was 8.55 (range: $2.49\~14.81$) in any component of failure and the median $SUV_{max}$ was 5.48 (range: $2.31\~26.07$) In the remaining patients without any such failure. Patients having tumors with high FDG uptake had a significantly lower 3-year DFS ($51\%\;{\nu}91\%$, p=0.0070) compared with patients having low uptake tumors. Conclusion : FDG uptake, as measured by the SUV, has potential value in predicting DFS in NPC treated by CCRT, High FDG uptake may be a useful parameter for Identifying patients requiring more aggressive treatment approaches.

Changes in the Standardized Uptake Value According to the Type of Metal of Dental Prosthesis in PET-CT Fusion Image (PET-CT 융합 영상에서 치과보철물의 금속 종류에 따른 표준섭취계수 값의 변화)

  • Han, Sang-Hyun
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.9
    • /
    • pp.117-122
    • /
    • 2018
  • In this study, HU(hounsfield unit) value of CT generated by dental prosthesis was measured according to the type of metal when PET-CT was performed, and the degree of distortion and standard deviation of SUV(standard uptake value) and to propose a method to reduce errors in image reading. PET-CT was performed using actual teeth, metal crown, gold crown, titanium, and zirconia dental prosthesis. Compared with general teeth, the SUV value increased with increasing HU value. The SUV value of metal crown, titanium, and zirconia was increased by 37% and the gold crown increased by 45.4%. In addition, image distortions were small in general teeth, metal crown, titanium, and zirconia, but hard curing of the gold crown occurred and image distortion occurred. Therefore, since the metal type of the dental prosthesis affects the SUV value, the NAC(non attenuation correction) PET image of the dental prosthesis can be helpful in the diagnosis of the patient using the gold material.

A Study of Standarzied Uptake Value Change on the Type of Mateiral (물질의 종류에 따른 표준섭취계수의 변화에 관한 연구)

  • Kim, Ki-Jin;Kim, Chong-Yeal;Bae, Seok-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.8
    • /
    • pp.3572-3578
    • /
    • 2011
  • In Positron Emission Tomography Computed Tomography, Standardized Uptake Value(SUV)is most generally used to discern tumors. However, SUV may be influenced other factors. In this study, experiment was conducted distrotion in image and change in SUV according to substance with GEMINI TF PET/CT of Philips.. SUV for materials resulted in 1.8 for stainless, 1.4 for stent, 2.4 for iodine contrast medium, 2.6 for Barium Sulfate, 1.6 for Gypsum, and 1.4 for paraffin respectively. The distortion of image was remarkable for the iodine contrast medium and Barium Sulfate. For the barium sulfate, the higher the density, the larger the distrotion of the images. As a result of test, it appeared that the metallic substance whose atomic number is low and contrast medium whose concentration is low didn't affect the distortion in image and the change in SUV. However, it tis necessary to minimize distortion in image and change in SUV, by removing the metallic substance and checking if there are contrast mdeium or before examination.

Usefulness of Dynamic $^{18}F-FDG$ PET Scan in Lung Cancer and Inflammation Disease (폐암과 폐 염증성질환의 동적양전자방출단층검사 (Dynamic $^{18}F-FDG$ PET)의 유용성)

  • Park, Hoon-Hee;Roh, Dong-Wook;Kim, Sei-Young;Rae, Dong-Kyeong;Lee, Min-Hye;Kang, Chun-Goo;Lim, Han-Sang;Oh, Ki-Back;Kim, Jae-Sam;Lee, Chang-Ho
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.249-255
    • /
    • 2006
  • Purpose: The diagnostic utility of fluorine-18 2-deoxy-D-glucose positron emission tomograhpy ($^{18}F-FDG $PET) for the non-invasive differentiation of focal lung lesions originated from cancer or inflammation disease by combined visual image interpretation and semi-quantitative uptake value analysis has been documented. In general, Standardized Uptake Value(SUV) is used to diagnose lung disease. But SUV does not contain dynamic information of lung tissue for the glucose. Therefore, this study was undertaken to hypothesis that analysis of dynamic kinetics of focal lung lesions base on $^{18}F-FDG$ PET may more accurately determine the lung disease. So we compared Time Activity Curve(TAC), Standardized Uptake Value-Dynamic Curve(SUV-DC) graph pattern with Glucose Metabolic Rate(MRGlu) from Patlak analysis. Methods: With lung disease, 17 patients were examined. They were injected with $^{18}F-FDG$ over 30-s into peripheral vein while acquisition of the serial transaxial tomographic images were started. For acquisition protocol, we used twelve 10-s, four 30-s, sixteen 60-s, five 300-s and one 900-s frame for 60 mins. Its images were analyzed by visual interpretation TAC, SUV-DC and a kinetic analysis(Patlak analysis). The latter was based on region of interest(ROIs) which were drawn with the lung disease shape. Each optimized patterns were compared with itself. Results: In TAC patterns, it hard to observe cancer type with inflammation disease in early pool blood area but over the time cancer type slope more remarkably increased than inflammation disease. SUV-DC was similar to TAC pattern. In the result of Patlak analysis, In time activity curve of aorta, even though inflammation disease showed higher blood activity than cancer, at first as time went by, blood activity of inflammation disease became the lowest. However, in time activity curve of tissue, cancer had the highest uptake and inflammation disease was in the middle. Conclusion: Through the examination, TAC and SUV-DC could approached the results that lung cancer type and inflammation disease type has it's own difference shape patterns. Also, it has outstanding differentiation between cancer type and inflammation in Patlak and MRGlu analysis. Through these analysis methods, it will helpful to separation lung disease.

  • PDF

The Usefulness of Integrated PET/CT to Distinguish between Benignancy and Malignancy in Solitary Pulmonary Nodule (고립성 폐결절의 악성 감별에서 Integrated PET/CT의 유용성)

  • Park, Won-Jong;Kim, Dong-Hee;Yu, Sung-Ken;Shin, Kyeong-Cheol;Chung, Jin-Hong;Lee, Kwan-Ho;Chun, Kyung-Ah;Cho, Ihn-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.23 no.2
    • /
    • pp.205-212
    • /
    • 2006
  • Background: Malignant pulmonary nodules account for about 30 to 40 percent of solitary pulmonary nodules (SPN). Therefore, tissue characterization of SPNs is very important. Recently, PET/CT has been widely used for tissue characterization, and has become of importance. The purpose of this study was to compare and to assess multiple factors in PET/CT comparing benign and malignant nodules. Materials and Method: Nineteen patients with SPN underwent PET/CT and biopsy. The difference of standardized uptake value 1 (SUV1), standardized uptake value 2 (SUV2) and retention index in PET/CT between malignancy and benignancy were compared by Levene's test. Result: There were twelve malignant and seven benign nodules. SUV1 and SUV2 were significantly different between malignant nodule and benign nodule (p=0.006 and 0.022), but retention index was not significantly different between malignant nodule and benign nodule (p=0.526). By receiver-operating-characteristic (ROC) analysis, the sensitivity was 66.7% and the specificity was 71.4% at a cut off value of 5.40 in SUV1. The sensitivity was 75% and the specificity was 71.4% at cut off value of 7.45 in SUV2. Conclusion: There was a statistically significant difference in SUV1 and SUV2 between benign and malignant nodules. However, the cut off value of SUV1 and SUV2 by receiver-operating-characteristic (ROC) analysis was 5.40 and 7.45 which is different from previous studies. Therefore, studies on a larger sample of patients are required for confirmation.

  • PDF

Clinical Reference of the Maximum Standardized Uptake Values to the Pancreatic Cancer, Pancreatitis and Normal Pancreas in the 18F-FDG PET-CT (18F-FDG PET-CT 검사에서 췌장암, 췌장염, 정상 췌장에 대한 최대 표준섭취계수의 임상적 기준 설정)

  • Lee, Jae-Seung;Kweon, Dae Cheol
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.2
    • /
    • pp.80-86
    • /
    • 2018
  • The aim of this study were to establish the clinical references and guidelines for the maximum standardized uptake ($SUV_{max}$) value of pancreatic cancer, pancreatitis, and normal pancreas in $^{18}F-FDG$ PET-CT examinations for pancreatic disease. For this purpose, we performed the statistical analysis on the descriptive statistics, percentiles and inter quartiles range (IQR), normal distribution, and using the probability density function for pancreatic cancer, pancreatitis, and normal pancreas. As a result, the clinical reference of $SUV_{max}$ for the pancreatic cancer, pancreatitis, and normal pancreas was more than 3.45, 1.91 to 2.62, and less than 1.91, respectively. Also, optimal cut-off value for applying the dual time point PET-CT examination was determined to be 2.62. The results of this study are summarized as follows: first, we suggests the clinical reference and guideline for the pancreatic cancer, pancreatitis, and normal pancreas, and second, suggests a scientific approach to improve diagnostic accuracy of pancreatic disease by deviating from an approximate experience approach.

Correlation between glucose transporter type-1 expression and $^{18}F$-FDG uptake on PET in oral cancer

  • Kim, Chul-Hwan;Kim, Moon-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.38 no.4
    • /
    • pp.212-220
    • /
    • 2012
  • Objectives: Fluorine-18 fluorodeoxyglucose positron emission tomography ($^{18}F$-FDG PET) is a non-invasive diagnostic tool for many human cancers wherein glucose uptake transporter-1 (GLUT-1) acts as a main transporter in the uptake of $^{18}F$-FDG in cancer cells. Increased expression of glucose transporter-1 has been reported in many human cancers. In this study, we investigated the correlation between $^{18}F$-FDG accumulation and expression of GLUT-1 in oral cancer. Materials and Methods: We evaluated 42 patients diagnosed with oral squamous cell carcinoma (OSCC) and malignant salivary gland tumor as confirmed by histology. 42 patients underwent pre-operative $^{18}F$-FDG PET, with the maximum standardized uptake value ($SUV_{max}$) measured in each case. Immunohistochemical staining was done for each histological specimen, and results were evaluated post-operatively according to the percentage (%) of positive area, intensity, and staining score. Results: For OSCC, $SUV_{max}$ significantly increased as T stage of tumor classification increased. For malignant salivary gland tumor, $SUV_{max}$ significantly increased as T stage of tumor classification increased. For OSCC, GLUT-1 was expressed in all 36 cases. GLUT-1 staining score (GSS) increased as T stage of tumor classification increased, with the difference statistically significant. For malignant salivary gland tumor, GLUT-1 expression was observed in all 6 cases; average GSS was significantly higher in patients with cervical lymph node metastasis than that in patients without cervical lymph node metastasis. Average GSS was higher in OSCC ($11.11{\pm}1.75$) than in malignant salivary gland tumor ($5.33{\pm}3.50$). No statistically significant correlation between GSS and $SUV_{max}$ was observed in OSCC or in malignant salivary gland tumor. Conclusion: We found no statistically significant correlation between GSS and $SUV_{max}$ in OSCC or in malignant salivary gland tumor. Studies on the various uses of GLUT during $^{18}F$-FDG uptake and SUV and GLUT as tumor prognosis factor need to be conducted through further investigation with large samples.

Analysis for Correlation of Standardized Uptake Value in Fusion Imaging Scanner (융합영상장비의 표준섭취계수 상관관계 분석)

  • Kim, Jin-Eui;Kim, Jung-Soo;Choi, Nam-Gil;Han, Jae-Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.593-601
    • /
    • 2018
  • Recently in nuclear medicine, to improve diagnostic value, SUV, semi-quantitative indicator used in PET-CT, is adopted in SPECT-CT. Therefore, this research analyzed correlation of $SUV_{max}$ of two scanners through phantom test, and evaluated possibility of clinical application. Radiopharmaceuticals ($^{18}F$, $^{99m}Tc$) were injected with the ratios of 8:1 and 4:1, considering background radioactivity, into the phantom manufactured with 6 globes of different sizes, and, based on clinical protocol, positive phases were acquired with PET-CT and SPECT-CT scanners, and interesting areas were divided into ROI and VOI, and $SUV_{max}$ of them were measured, and analyzed. Tests found out no statistically significant difference in $SUV_{max}$ measured with two scanners (P>0.05). Thus, $SUV_{max}$ of PET-CT and SPECT-CT had a certain correlation within significant levels, and were evaluated as the same. Accordingly, it seems that $SUV_{max}$ quantitative analysis using SPECT-CT can provide significant diagnostic information as the case of PET-CT.