Effects of Low Temperature Plasma Nitriding Treatment on Corrosion behavior of Stainless Steel (스테인리스강의 내식성에 미치는 저온 플라즈마 질화의 영향)

  • Kim, H.G.;Bin, J.U.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.24 no.1
    • /
    • pp.3-9
    • /
    • 2011
  • Plasma nitriding of stainless steels has been investigated over a range of temperature from 400 to $500^{\circ}C$ and time from 10 to 20 hours. Characterization of systematic materials was carried out in terms of mechanical properties and corrosion behaviors. The results showed that plasma nitriding conducted at low temperatures not only increased the surface hardness, but also improved the corrosion resistance of STS 316L, STS409L, and STS 420J2. It was found that plasma-nitriding treatment at $500^{\circ}C$ resulted in increasing the corrosion performance of STS 409L and STS 420J2, while STS 316L was observed with server and massive damage on surface due to the formation of CrN.

Effect of Heat Treatment Characteristic on the Gas Nitriding of Stainless Steels (스테인리스강의 가스질화에 미치는 열처리 조건의 영향에 관한 연구)

  • Kim, H.G.;Hwang, G.S.;Sun, C.G.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.16 no.2
    • /
    • pp.78-82
    • /
    • 2003
  • Nitrided compound layer and diffusion layer structure were observed by SEM. The compound layer and the constituent of nitrided surface of STS 304, STS 316, STS 410 and SACM 645 steel were analysed using EMPA and XRD respectively. The depth of nitriding layer that is obtained from similar nitriding condition decrease in the order of SACM 645 > STS 410 > STS 316 > STS 304. Result of phase transformation of the nitrided at $550^{\circ}C$ by XRD analysis were as follows; The austenitic stainless steel was mainly consist of $Cr_2N$ accompanying with $Fe_4N$ and $Fe_{2-3}N$ phase and martensitic stainless steel was mainly consist of present $Fe_{2-3}N+Cr_2N$ phase, but SACM 645 steel was $Fe_{2-3}N$ phase present only.

The Effect of Long Term Thermal Aging on High Temperature Mechanical Properties in STS316 (장시간 시효처리가 316 스트인리스 강의 고온 기계적 성질에 미치는 영향)

  • 임지우;정찬서;임병수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.2
    • /
    • pp.110-116
    • /
    • 2002
  • At elevated temperature, very complex precipitations occur in STS316. To investigate the effect of the precipitation on mechanical properties in SIS316, tensile tests and fatigue crack growth tests were carried out at $650^{\circ}C$ using artificially degraded materials. The material degradation was simulated by aging for up to 20000 hrs. at $750^{\circ}C$, which is equal to 179000hrs (about 20yrs) of service life at $650^{\circ}C$, after conducting solution treatment for 20 min. at $11300^{\circ}C$. The result of the hardness test and the tensile test showed that both properties are closely related to the mean free distance of carbides. Also, from the results of fracture tests at $650^{\circ}C$, ${\triangle}K_{th}$, after values were found to decrease as aging time and microstructure, as the volume fraction of $\sigma$ phase increased.

On Dissimilar Friction Welded Joints(STS316L/IN X-750) of Turning Vane Bolt (Turning Vane Bolt의 이종재(STS316L/IN X-750) 마찰용접에 관하여)

  • SHIN KI-SUK;KONG YU-SIK;KIM SEON-JIN;RYOO IN-IL
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.331-336
    • /
    • 2004
  • Dissimilar friction welding were produced using 10mm and 11mm diameter solid bar in Inconel ally(IN X-750) to Stainless steel(STS316L) to investigate their mechanical properties. The main friction welding parameters were selected to endure good quality welds on the basis of visual examination, tensile tests, Virkers hardness surveys of the bond of area and HAZ and macro-structure investigations. The specimens were tested as welded, not heat-treated. The tensile strength of the friction welded steel bars was increased up to $95\%$ of the STS316L base metal under the condition of all heating time. Optimal welding conditions were n=2,000(rpm), $P_1=220(MPa),\;P_2=260(MPa),\;t_1=4(s),\;t_2=4(s)$ when the total upset length is 7(mm).

  • PDF

Study on Optimization of Dissimilar friction Welding of Nuclear Power Plant Materials (Cu Alloy/STS316L) and Its Real Time AE Evaluation (원자력 발전소용 이종재(Cu 합금/STS316L) 마찰용접의 최적화와 AE에 의한 실시간 평가에 관한 연구)

  • 유인종;권상우;황성필;공유식;오세규
    • Journal of Ocean Engineering and Technology
    • /
    • v.15 no.2
    • /
    • pp.88-93
    • /
    • 2001
  • In this paper, joints of Cu-1Cr-0.1Zr alloy to STS316L were performed by friction welding method. Particularly, Cu-1Cr-0.1Zr alloy is attractive candidate as nuclear power plant material and exibit the best combination of high strength and good electrical and thermal conductivity of any copper alloy examined. The stainless steel is a structural material while copper alloy acts as a heat sink material for the surface heat flux in the first wall. So, in this paper, not only the development of optimizing of friction welding with more reliability and more applicability but also the development of in-process real-time weld quality (such as strength and toughness) evaluation technique by acoustic emission for friction welding of such nuclear reactor component of Cu-1Cr-0.1Zr alloy to STS316L steel sere performed.

  • PDF

Electrochemical Evaluation of Si-Incorporated Diamond-Like Carbon (DLC) Coatings Deposited on STS 316L and Ti Alloy for Biomedical Applications

  • Kim, Jung-Gu;Lee, Kwang-Ryeol;Kim, Young-Sik;Hwang, Woon-Suk
    • Corrosion Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.18-23
    • /
    • 2007
  • DLC coatings have been deposited onto substrate of STS 316L and Ti alloy using r.f. PACVD (plasma-assisted chemical vapor deposition) with a mixture of $C_{6}H_{6}$ and $SiH_{4}$ as the process gases. Corrosion performance of DLC coatings was investigated by electrochemical techniques (potentiodynamic polarization test and electrochemical impedance spectroscopy) and surface analysis (scanning electron microscopy). The electrolyte used in this test was a 0.89% NaCl solution of pH 7.4 at temperature $37^{\circ}C$. The porosity and protective efficiency of DLC coatings were obtained using potentiodynamic polarization test. Moreover, the delamination area and volume fraction of water uptake of DLC coatings as a function of immersion time were calculated using electrochemical impedance spectroscopy. This study provides the reliable and quantitative data for assessment of the effect of substrate on corrosion performance of Si-DLC coatings. The results showed that Si-DLC coating on Ti alloy could improve corrosion resistance more than that on STS 316L in the simulated body fluid environment. This could be attributed to the formation of a dense and low-porosity coating, which impedes the penetration of water and ions.

Elastic Wave Properties of STS316L with Different Subzero Temperature and Time (서브제로 온도 및 시간이 다른 STS316L의 탄성파 특성)

  • Lee, Gum-Hwa;Gu, Kyoung-Hee;Tak, Young-Joon;Kwon, Yung-Kug;Shin, Ki-Hang;Nam, Ki-Woo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.5
    • /
    • pp.783-789
    • /
    • 2022
  • In this study, STS316L rolled at five rolling degrees were treated with two types of subzero temperatures for 10, 30, and 60 minutes, respectively, and the dominant frequencies of elastic waves was investigated. The dominant frequency was higher as the subzero temperature was lower and the subzero treatment time was longer at each rolling degree. On the other hand, the dominant frequency was higher as the elongation decreased. In the time-frequency analysis for subzero temperature and time of the specimen with a rolling degree of 33%, the dominant frequency was higher at a subzero temperature of -196℃ than -50℃ regardless of subzero treatment time.

고질소 첨가 316L 스테인리스강의 품질특성 연구

  • 김광태;이종석;이용득
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05b
    • /
    • pp.761-766
    • /
    • 1995
  • STS 316L 강은 합금성분 중 탄소 함량을 0.03wt.% 이하로 규제하여 내식성이 향상되었고 용접 후 열처리가 불필요하여 널리 사용되어 왔으나, 탄소의 함량이 낮아 강도가 낮으므로 N을 첨가하여 강도를 높인 강으로 대체되는 추세이다. STS 316L 강에 첨가되는 N함량을 0.041∼0.15wt.% 범위로 변화시켜 N 첨가량에 따라 열간 압연 중 변형저항이 변화되는 정도를 측정하였으며, 동시에 최종제품의 기계적 성질, 입계예민화 정도, 충격특성 및 내 SCC성 변화를 조사하였다. N 첨가량이 증가할수록 열간 압연은 힘들어지나, 품질특성은 향상됨을 알 수 있었다.

  • PDF

Effects of Chlorine Residual and Pipe Material on the Biofilm Formation in Drinking Water Distribution Pipe (수도관의 생물막 형성에 미치는 잔류염소와 파이프 재질의 영향)

  • Park, Se-keun;Park, Jae-Woo;Sung, Kwon-Shic;Choi, Sung-Chan;Kim, Yeong-Kwan
    • Journal of Industrial Technology
    • /
    • v.21 no.B
    • /
    • pp.11-20
    • /
    • 2001
  • This laboratory study examined the impact of free chlorine residual and pipe material on the formation of biofilm in drinking water distribution pipe surfaces. Result of heterotrophic plate counts(HPC) of the biofilm in the tap water-supplied reactor averaged $2.17{\times}10^5CFU/cm^2$ on PVC and $2.43{\times}10^5CFU/cm^2$ on STS 316, respectively. HPCs on the surface exposed to the tap water containing 0.2mg/L of free chlorinne residual averaged $4.24{\times}10^4CFU/cm^2$ on PVC and $6.54{\times}10^4CFU/cm^2$ on STS 316, respectively. Average of HPC/Total direct counts in the tap water-supplied reactor ranged from 1.08%(PVC) to 1.26%(STS 316) and from 0.38%(PVC) to 0.65%(STS 316) in the reactor supplemented with disinfectant, respectively. No correlation was observed between disinfectant addition and biofilm density. With regard to the biofilm formation, little difference existed between PVC and STS 316. Yellow and red pigmented bacteria were the dominant expressions in bulk fluid, whereas non-pigmented bacteria were found dominant in the biofilm. Pink/red pigmented bacteria were found to be facultative anaerobic, while yellow pigmented bacteria and non-pigmented bacteria were found to be obligate aerobic.

  • PDF