• Title/Summary/Keyword: SPES

Search Result 37, Processing Time 0.019 seconds

Analysis of electrochemical double-layer capacitors using a Natural Rubber-Zn based polymer electrolyte

  • Nanditha Rajapaksha;Kumudu S. Perera;Kamal P. Vidanapathirana
    • Advances in Energy Research
    • /
    • v.8 no.1
    • /
    • pp.41-57
    • /
    • 2022
  • Electrochemical double-layer capacitors (EDLCs) based on solid polymer electrolytes (SPEs) have gained an immense recognition in the present world due to their unique properties. This study is about preparing and characterizing EDLCs using a natural rubber (NR) based SPE with natural graphite (NG) electrodes. NR electrolyte was consisted with 49% methyl grafted natural rubber (MG49) and zinc trifluoromethanesulfonate ((Zn(CF3SO3)2-ZnTF). It was characterized using electrochemical impedance spectroscopy (EIS) test, dc polarization test and linear sweep voltammetry (LSV) test. NG electrodes were made using a slurry of NG and acetone. EIS test, cyclic voltammetry (CV) test and galvanostatic charge discharge (GCD) test have been done to characterize the EDLC. Optimized electrolyte composition with NR: 0.6 ZnTF (weight basis) exhibited a conductivity of 0.6 x 10-4 Scm-1 at room temperature. Conductivity was predominantly due to ions. The electrochemical stability window was found to be from 0.25 V to 2.500 V. Electrolyte was sandwiched between two identical NG electrodes to fabricate an EDLC. Single electrode specific capacitance was about 2.26 Fg-1 whereas the single electrode discharge capacitance was about 1.17 Fg-1. The EDLC with this novel NR-ZnTF based SPE evidences its suitability to be used for different applications with further improvement.

The Electrochemical Studies of Two Osmium Redox Polymer Films and Their Application for Multi-Detecting Biosensor (전기화학적인 방법을 이용한 두 개의 오스뮴 고분자 막의 고정화 및 다중 검출 바이오센서에 관한 연구)

  • Tae, Gun-Sik;Kim, Jin-Gu;Choi, Young-Bong;Kim, Hyug-Han
    • Journal of the Korean Electrochemical Society
    • /
    • v.11 no.3
    • /
    • pp.170-175
    • /
    • 2008
  • Screen printed carbon electrodes (SPEs) modified with co-immobilized osmium-based redox polymers can be used to apply multi-detecting biosensors. In this study, we report our initial studies of multi-detecting biosensor concepts using two osmium-based redox polymers for horseradish peroxidase-mediated reduction of ${H_2}{O_2}$ coupled to glucose oxidase-mediated oxidation of glucose. We target to synthesize two osmium redox polymers of potentials use, a chloride-containing redox polymer ($E^{O'}$ + 0.520 vs. Ag/AgCl) and a methoxy-containing redox polymer $E^{O'}$ + 0.150 vs. Ag/AgCl). The former show good catalytic electrical signals with horseradish peroxidase and the latter's redox polymer is to be an effective redox mediator of glucose oxidation by glucose oxidase.

Synthesis of Osmium Redox Complex and Its Application for Biosensor Using an Electrochemical Method (오스뮴 착물 합성과 전기화학적인 방법을 이용한 바이오센서에 관한 연구)

  • Choi, Young-Bong;Kim, Hyug-Han
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.2
    • /
    • pp.150-154
    • /
    • 2007
  • Redox complexes to transport electrodes from biomaterial to electrodes are very important part in commercial biosensor industry. A novel osmium redox complex was synthesized by the coordinating pyridine group with osmium metal. A novel osmium complex is described as $[Os(dme-bpy)_2(ap-im)Cl]^{+/2+}$. We have been studied the electrochemical characteristics of this osmium complex with electrochemical techniques such as cyclic voltammetry and chronoamperommetry. In order to immobilize osmium redox complexes on the electrode, we deposited gold nano-particles on screen printed carbon electrode(SPE). The electrical signal converts the osmium redox films into an electrocatalyst for glucose oxidation. The catalytic currents were monitored that the catalytic currents were linearly increased from 1 mM to 5 mM concentrations of glucose.

Preparation and Characterization of SPAES/SPVdF-co-HFP Blending Membranes for Polymer Electrolyte Membrane Fuel Cells (고분자 전해질 연료전지용 술폰화된 폴리(아릴렌 이써 설폰)/SPVdF-co-HFP 브렌딩 멤브레인의 제조 및 특성 분석)

  • PARK, CHUL JIN;KIM, AE RHAN;YOO, DONG JIN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.3
    • /
    • pp.227-236
    • /
    • 2019
  • In this work, preparation and characterizations of hybrid membranes containing sulfonated poly(arylene ether sulfone) (SPES) and sulfonated poly(vinylidene fluoride-co-hexafluoropropylene) (SPVdF-co-HFP) (20, 30 or 40 wt%) were carried out. The structure of hybrid membranes was confirmed using X-ray diffraction (XRD) analysis and the Fourier transform infrared (FT-IR) spectroscopy. The prepared SPAES/SPVdF-30 membrane exhibits higher ionic conductivity of 68.9 mS/cm at $90^{\circ}C$ and 100% RH. Besides, the other studies showed that the hybrid membrane has good oxidation stability, thermal stability, and mechanical stability. Thus, we believe that the prepared hybrid membrane is suitable for the development of membranes for fuel cell applications.

Recent Applications of Molecularly Imprinted Polymers (MIPs) on Screen-Printed Electrodes for Pesticide Detection

  • Adilah Mohamed Nageib;Amanatuzzakiah Abdul Halim;Anis Nurashikin Nordin;Fathilah Ali
    • Journal of Electrochemical Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.1-14
    • /
    • 2023
  • The overuse of pesticides in agricultural sectors exposes people to food contamination. Pesticides are toxic to humans and can have both acute and chronic health effects. To protect food consumers from the adverse effects of pesticides, a rapid monitoring system of the residues is in dire need. Molecularly imprinted polymer (MIP) on a screen-printed electrode (SPE) is a leading and promising electrochemical sensing approach for the detection of several residues including pesticides. Despite the huge development in analytical instrumentation developed for contaminant detection in recent years such as HPLC and GC/MS, these conventional techniques are time-consuming and labor-intensive. Additionally, the imprinted SPE detection system offers a simple portable setup where all electrodes are integrated into a single strip, and a more affordable approach compared to MIP attached to traditional rod electrodes. Recently, numerous reviews have been published on the production and sensing applications of MIPs however, the research field lacks reviews on the use of MIPs on electrochemical sensors utilizing the SPE technology. This paper presents a distinguished overview of the MIP technique used on bare and modified SPEs for the detection of pesticides from four recent publications which are malathion, chlorpyrifos, paraoxon and cyhexatin. Different molecular imprint routes were used to prepare these biomimetic sensors including solution polymerization, thermal polymerization, and electropolymerization. The unique characteristics of each MIP-modified SPE are discussed and the comparison among the findings of the papers is critically reviewed.

Water Quality Management of Simple Piped Water Supply System and Its Satisfaction of the Residents (簡易上水道의 水質管理實態와 給水利用住民의 滿足度)

  • Chae, Han-Uk;Park, Jae-Yong;Moon, Hyo-Jung
    • Journal of Environmental Health Sciences
    • /
    • v.25 no.3
    • /
    • pp.13-22
    • /
    • 1999
  • For the purpose of inquiring into the actual conditions of water quality management of Simple Piped Water Supply(SPWS) and the satisfaction and attitudes of inhabitants about utilizing water-supply, this research was done through the questionnaires, the investigation of surrounding environment and water quality analysis in the Sangju city, Kyungsang-pookdo during 4 months from March to June, 1998. The fountainhead of SPES using ground water accounted for 65.3%, which was the highest rate in the group. Most of them was at least 10 years in the number of utilization year. 79.6% of them were exposed to many sorts of surrounding pollution origins. The examination of water was performed only through a test about water purification and 24.5% of them disinfection by chlorine also no residual chlorine was detected at all. All the waterworks did not have any education to the managers of water quality and 81.5% of them held physical examination. As a result of the water examination about SPWS, 65.3% of them were found incongruity and the valley and springing water accounted for higher than the underground water in the rate of incongruity. Looking into the details of the result in the water examination, a category of colon bacilli was ranked in the highest rate and the next one was general bacilli, nitric acid nitrogen and turbidity in order. In the satisfaction degree of the water quality, the satisfied accounted for 44.6%, and 29.2% each. Over the state of satisfaction about the ways of water examination, satisfaction accounted for 44.6%, and unsatisfaction 28.3%. Summarizing the result of the above-stated, the state of Water Quality Management of the SPWS was in a poor condition. Thus for the water Quality Management, systematic and scientific water Quality Management mainly by the administrative organization other than voluntary management by the village should be done beyond doubt. Additionally the opinions and demands of inhabitants utilizing the water supply have to be positively reflected in the affairs of water Quality Management so that the distrust of inhabitants to the SPWS should be settled.

  • PDF

Effects of Ethanol on Neurobehavioral Performance (컴퓨터를 이용한 에탄올에 의한 신경행동기능 장애 평가)

  • Jeon, Man-Joong;SaKong, Joon;Kang, Pock-Soo;Kim, Moon-Chan;Kim, Hak-Soo
    • Journal of Yeungnam Medical Science
    • /
    • v.14 no.1
    • /
    • pp.183-196
    • /
    • 1997
  • An experimental study was performed to investigate. The subjects drank (0.5g/kg ethanol and performed 7 items of SPES(simple reaction time, color word stress, digit classification, finger tapping speed, numerical ability, symbol digit coding, memory digit span). 20 students of medical college participated in the study during August, 1996. After ethanol intake, performance of 4 items(simple reaction time, digit classification, finger tapping speed, symbol digit coding) significantly showed to be decreased. The function of perception-response speed and steady movement were found to be more sensitive to ethanol than that of short-term memory, numerical ability and specification of color. No significant association were found between smoking, alcohol drinking, BMI(body mass index) and the effects of ethanol on neurobehavioral performance.

  • PDF