• Title/Summary/Keyword: SPDS

Search Result 53, Processing Time 0.021 seconds

Generation of Split Plot Design of Fixed Factors by Random, Crossed, and Nested Models (랜덤, 교차, 지분인자 모형에 의한 고정인자 분할구 실험설계의 생성)

  • Choi, Sung-Woon
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2011.04a
    • /
    • pp.487-493
    • /
    • 2011
  • The paper reviews three Split Plot Designs (SPDs) of fixed factors, and those are SPD (RCBD, RCBD), SPD (CRD, RCBD) and SBD (Split Block Design). RCBD (Randomized Complete Block Design) and CRD (Completely Randomized Design) are used to deploy whole plot and sub plot. The models explained in this study are derived from random, crossed and nested models.

  • PDF

REffects of Surge Protective Devices with Respect to Types of System Grounding and Wiring Methods (전원계통의 접지방식 및 배선방식에 따른 서지보호기의 효과)

  • 이수봉;이복희;길형준
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.2
    • /
    • pp.90-99
    • /
    • 2004
  • High speed info-communications equipment are required with development of highly information-oriented society, the intelligent industrial facilities and social systems such as administrative, financial and traffic systems, are gradually becoming to automation, which are composed of the integrated circuits and micro-semiconductors, remote control and operation. Thus modern micro-electronic circuits can frequently be damaged by lightning surge. The protection of electronic circuits from lightning overvoltages is concentrated very interesting. In this paper, for the purpose of providing the effective protection method of electronic devices such micro-computers from lightning surges in a residential building, the protection effect of surge protective devices according to types of system groundings were experimentally analyzed. Also the effective installation method of surge protective devices was examined and proposed. The installation of SPDs in retrofits was a high remnant voltage across the protected device owing to the inductance in the long wires to the SPDs. Finally the method of installing the SPD by twisted pain wires is remarkably effective for fast rising transient overvoltages.

Deterioration Characteristics and an On-Line Diagnostic Equipment for Surge Protective Devices (서지 보호기의 열화 특성과 온라인 진단장치)

  • Park, Kyoung-Soo;Wang, Guoming;Hwang, Seong-Cheol;Kim, Sun-Jae;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.10
    • /
    • pp.635-640
    • /
    • 2016
  • This paper dealt with the deterioration characteristics and an on-line diagnosis equipment for SPDs (surge protective devices). An accelerated aging test was carried out using a $8/20{\mu}s$ standard lightning impulse current to analyze the changes of electrical characteristics and to propose the diagnostic parameters and the criterion for deterioration of ZnO varistor which is the core component of SPDs. Based on the experimental results, an on-line diagnosis equipment for SPD was fabricated, which can measure the total leakage current, reference and clamping voltage. The leakage current measurement circuit was designed using a low-noise amplifier and a clamp type ZCT. A linear controller, the leakage current measurement part and a HVDC were used in the measurement of reference voltage. The measurement circuit of clamping voltage consisted of a surge generator and a coupling circuit. In a calibration process, measurement error of the prototype equipment was less than 3%.

New N-dimensional Basis Functions for Modeling Surface Reflectance (표면반사율 모델링을 위한 새로운 N차원 기저함수)

  • Kwon, Oh-Seol
    • Journal of Broadcast Engineering
    • /
    • v.17 no.1
    • /
    • pp.195-198
    • /
    • 2012
  • The N basis functions are typically chosen so that Surface reflectance functions(SRFs) and spectral power distributions (SPDs) can be accurately reconstructed from their N-dimensional vector codes. Typical rendering applications assume that the resulting mapping is an isomorphism where vector operations of addition, scalar multiplication, component-wise multiplication on the N-vectors can be used to model physical operations such as superposition of lights, light-surface interactions and inter-reflection. The vector operations do not mirror the physical. However, if the choice of basis functions is restricted to characteristic functions then the resulting map between SPDs/SRFs and N-vectors is anisomorphism that preserves the physical operations needed in rendering. This paper will show how to select optimal characteristic function bases of any dimension N (number of basis functions) and also evaluate how accurately a large set of Munsell color chips can approximated as basis functions of dimension N.

Development of an Operator Aid System For The Nuclear Plant Severe Accident Training and Management

  • Kim Ko Ryu;Park Sun Hee;Kim Dong Ha
    • International Journal of Safety
    • /
    • v.3 no.1
    • /
    • pp.32-37
    • /
    • 2004
  • Recently KAERI has developed the severe accident management guidance to establish Korea standard severe accident management system. On the other hand the PC-based severe accident training simulator SATS has been developed, and the MELCOR code is used as the simulation engine. SATS graphically displays and simulates the severe accidents with interactive user commands. The control capability of SATS could make a severe accident training course more interesting and effective. In this paper the development and functions of the electrical hypertext guidance module HyperKAMG and the SATS-HyperKAMG linkage system for the severe accident management are described.

Severe Accident Management Using PSA Event Tree Technology

  • Choi, Young;Jeong, Kwang Sub;Park, SooYong
    • International Journal of Safety
    • /
    • v.2 no.1
    • /
    • pp.50-56
    • /
    • 2003
  • There are a lot of uncertainties in the severe accident phenomena and scenarios in nuclear power plants (NPPs) and one of the major issues for severe accident management is the reduction of these uncertainties. The severe accident management aid system using Probabilistic Safety Assessments (PSA) technology is developed for the management staff in order to reduce the uncertainties. The developed system includes the graphical display for plant and equipment status, previous research results by a knowledge-base technique, and the expected plant behavior using PSA. The plant model used in this paper is oriented to identify plant response and vulnerabilities via analyzing the quantified results, and to set up a framework for an accident management program based on these analysis results. Therefore the developed system may playa central role of information source for decision-making for severe accident management, and will be used as a training tool for severe accident management.

Data Transmission over Power Line with Lightning Protection Devices

  • Kim, Sungeon;Jeon, Taehyun
    • International journal of advanced smart convergence
    • /
    • v.2 no.1
    • /
    • pp.27-29
    • /
    • 2013
  • This paper discusses comparative analysis of the effects of surge protection devices (SPD) upon the power line communication channels. The quality of the data transmission channel is measured based on the data rate for the various channel parameters which include channel length and application method of the lightning protection device. The performance measurements are also carried out for various lengths of the communication channel. Experiment results show that specific combination of SPDs applied in the network causes severe degradation of the channel quality which is associated with the combination of grade levels and channel lengths.

Energy consumption by Spectral Power Distribution Of LED lighting (LED 조명의 분광 분포에 따른 건물에너지 소비)

  • Jung, Ho-Youn;Kim, Hyo-In;Kim, Gon;Yun, Geun-Young
    • KIEAE Journal
    • /
    • v.12 no.3
    • /
    • pp.101-106
    • /
    • 2012
  • Lighting energy accounts for approximately 20% of the electrical energy used worldwide. Thus, High efficiency Light emitting diode(LED)lighting is getting more popular as the next generation lighting replaced to traditional lighting fixtures. Also, LED lighting not only has a long lifetime but also can realize a variety visual environments through the wavelengh control. The lighting energy varies depending on the Spectral Power Distribution(SPD) even though the Illuminance level is same. Therefore, This study indicates that the difference of indoor energy consumption under the same illuminance level when Spectral Power Distribution(SPD) is different. As a result, Lighting energy consumption under red-color emphasizing SPD is about 10% lower than under blue-color emphasizing SPDs.

Experimental Study on Temporary Overvoltage Characteristic of Surge Protective Devices (서지보호기의 일시과전압특성에 대한 실험적 연구)

  • Shim, Hae-Sup;Jeon, Tae-Hyun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.344-347
    • /
    • 2009
  • Surge protective devices (SPD) have a special position because of the expectation that they perform an effective protective function against various kinds of surges. However, there exists a misconception that the SPD satisfying lower measured limiting voltage (MLV) should also protect equipment against temporary overvoltages (TOVs) as well. This paper inspects various types of MOV based SPDs and carry out experiments on the side effects of the low MLV characteristics. The experiment results show that a low MLV could cause a higher TOV-induced SPD failure rate in the field.

  • PDF

Melatonin Suppression under LED Lighting Focused on Spectral Power Distribution Differences

  • Hong, Seong-Kwan;Kim, Kyoung-Sil;Kim, In-Tae;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.8
    • /
    • pp.7-17
    • /
    • 2015
  • Changes in melatonin concentration levels by differences in CCT of white LED light focused on Spectral Power Distribution (SPD) differences compared to the same CCT of conventional fluorescent light were analyzed. For this, melatonin concentration levels in saliva samples were taken over four different experiments at seven-day intervals. In 71.4% of participants, it was confirmed that melatonin concentration is suppressed by exposure to light, and a slight difference was observed by different CCTs. In addition, Experiment II with a high CCT was relatively high in terms of the melatonin suppression rate compared to Experiment III. A key finding was the possibility that different SPDs under a particular CCT of white LED light compared to the same CCT of conventional fluorescent light could have the same effect on the melatonin suppression.