• Title/Summary/Keyword: SPD(Surge Protective Device)

Search Result 38, Processing Time 0.026 seconds

REffects of Surge Protective Devices with Respect to Types of System Grounding and Wiring Methods (전원계통의 접지방식 및 배선방식에 따른 서지보호기의 효과)

  • 이수봉;이복희;길형준
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.2
    • /
    • pp.90-99
    • /
    • 2004
  • High speed info-communications equipment are required with development of highly information-oriented society, the intelligent industrial facilities and social systems such as administrative, financial and traffic systems, are gradually becoming to automation, which are composed of the integrated circuits and micro-semiconductors, remote control and operation. Thus modern micro-electronic circuits can frequently be damaged by lightning surge. The protection of electronic circuits from lightning overvoltages is concentrated very interesting. In this paper, for the purpose of providing the effective protection method of electronic devices such micro-computers from lightning surges in a residential building, the protection effect of surge protective devices according to types of system groundings were experimentally analyzed. Also the effective installation method of surge protective devices was examined and proposed. The installation of SPDs in retrofits was a high remnant voltage across the protected device owing to the inductance in the long wires to the SPDs. Finally the method of installing the SPD by twisted pain wires is remarkably effective for fast rising transient overvoltages.

Protection Effects According to the Conditions of Installations of SPDs for Information-Oriented Equipments (정보화 기기용 SPD의 설치조건에 따른 보호효과)

  • Lee, Bok-Hee;Lee, Dong-Moon;Cheong, Dong-Chul;Lee, Su-Bong;Lee, Seung-Chil
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.1
    • /
    • pp.35-41
    • /
    • 2007
  • Recently, there are increasing social needs for stable supply of electric power and securing high quality of information and communication services. In this work, to propose the effective protection countermeasures of information-oriented equipments against lightning surges, the protection effects of surge protective devices(SPDs) were experimentally investigated using actual-sized test circuits in various installation conditions. As a result, it was found that the protection effect of SPDs is quite different depending on the factors, such as the grounding system of power source, numbers of branch circuits, wiring method of grounding leads, and etc. In case of installing SPDs for information-oriented equipments, including all electric power lines and communication lines, the common grounding should be the most effective. Wiring method containing grounding leads with power lines in metal conduit is suitable to improve the surge cutoff performance of SPDs.

Surge Voltage Distribution at the Different Bonding Practice During a Direct Lightning Stroke to Building (건물의 직격뢰시 본딩 방식에 따른 서지 진압 분포)

  • Lee, Jae-Bok;Chang, Sug-Hun;Myung, Sung-Ho;Cho, Yuen-Gue
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.4
    • /
    • pp.444-450
    • /
    • 2008
  • There are several ways to bond to building grounding systems for reducing GPR(ground potential rise) and EMI resulting from power system faults or lightning stroke to building. In order to verify effective bonding practice, the GPR and voltage of equipment due to the direct stroke to building are calculated with ATP-EMTP model for transformer, transmission line and MOV(Metal oxide varistor). The simulated model shows a satisfactory accuracy compared with experimental result for the $8/20{\mu}s$ simulated current pulse. It is observed that separate grounding can cause dangerous voltage to the building equipment and the performance of surge protective device can improve when it is installed to the protected equipment in distance as short as possible.

Design Circuit Parameter Estimation of Impulse Generator and its application to 10/350${\mu}s$ Lightning Impulse Current Generator (임펄스 발생기의 회로 설계 파라미터 예측계산과 10/350${\mu}s$ 뇌임펄스 전류발생기 적용)

  • Lee, Jae-Bok;Shenderey, S. V.;Chang, Sug-Hun;Myung, Sung-Ho;Cho, Yuen-Gue
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1822-1828
    • /
    • 2008
  • This paper presents design parameter calculation methodology and its realization to construction for the 10/350${\mu}s$ lightning impulse current generator(ICG) modelled as double exponential function waveform with characteristic parameters ${\alpha},{\beta}$. Matlab internal function, "fzero" was applied to find ${\lambda}={\alpha}/{\beta}$ which is solution of nonlinear equation linearly related with two wave parameter $T_1$ and $T_2$. The calculation results for 10/350${\mu}s$ lightning impulse current show very good accuracy with error less 0.03%. Two type of 10/350${\mu}s$ ICGs based on the calculated design circuit parameters were fabricated by considering the load variation. One is applicable to the MOV based Surge protective device(SPD) for less 15 kA and the other is to test small resistive devices such as spark gap arrester and bonding device with maximum current capability 30 kA. The tested waveforms show error within 10% in comparison with the designed estimation and the waveform tolerance recommended in the IEC 61643-1 and IEC 60060-1.

An Effective Installation Method of lightning Protective Devices for Information and Communication Facilities (정보통신설비용 뇌서지 보호장치의 효과적인 설치기법)

  • 이복희;이동문;강성만;엄주홍;이승칠
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.5
    • /
    • pp.90-96
    • /
    • 2002
  • The AC power lines and signal lines of info-communication networks are muted on overhead poles and are exposed to lightning strikes. Due to the potential difference between groundings of the AC power lines and telecommunication lines, the electronic equipments connected to the telecommunication lines can easily be damaged by lightning surges. In this work, in order to develop the reliable ways to protect information and communication facilities from lightning surges, the reliability and performance of surge protective devices were experimentally investigated in actual-sized test circuit. The operation behaviors of surge protective devices against lightning surges from the AC power lines and telecommunication lines and the coordination effects of SPD installation method were evaluated. As a consequence, it was confirmed that the bypass arrester and common grounding system is very effective.

Stability Evaluation of Series and Parallel Varistor Combination Using Thermal Image Analysis (열화상 분석을 통한 바리스터의 직렬과 병렬 조합의 안전성 평가)

  • Eom, Ju-Hong;Cho, Sung-Chul;Lee, Tae-Hyung;Han, Hoo-Sek
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.8
    • /
    • pp.22-29
    • /
    • 2006
  • According to the recent revision of KS on the basis of the IEC, equipotential grounding systems has been come into focus and the use of surge protective devices(SPD) has been increased radically in order to operate the power system stably. $Z_nO$ varistor with non-linear resistance, which has an outstanding voltage-current(V-I) characteristic, is mainly used in power system to limit surge voltage and divert surge current. $Z_nO$ varistors are packaged several types based on the circuit assembly to be connected to a.c. power line. When the user assemble the $Z_nO$ varistors into parallel or series circuit package, there are my things to be taken into consideration including functions and thermal stability because they are directly related to the safety. We compare stabilities of each assembly type by measuring residual voltage, discharge current, leakage current and surface temperature concerned to the protection performances between a single device with a 40[kA] of current capacity and parallel or series circuits type of varistor package.

Temporary Over Voltage Test System for Surge Protective Device in Low Distribution system (배전계통의 순간전압 상승에 따른 SPD 고압 TOV 시험설비 구축)

  • Kim, Young-Sung;Kim, Oun-Seok;Ahn, Gun-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1391_1392
    • /
    • 2009
  • 본 논문에서는 저압 서지보호기의 안전성평가를 위한 고압 계통 고장에 의한 순간 과전압시험 설비를 IEC 61643-1의 따라 구축 하였고, 구축된 시험설비의 성능을 분석하였다. 고압 계통의 순간 과전압시험 기준은 가장 일반적인 미국전력 계통의 기준인 3상 4선식이 반영이 되었으며 전압의 크기는 AC 1200V이다. 본 논문에서는 순간과전압이 상과 접지사이의 개방전압 AC 1200V을 약 200ms 동안 인가되는지를 측정하였고, 단락전류가 AC 300A이상을 측정하였다.

  • PDF

A Study on the Countermeasure Algorithm for Power System Disturbance in Large Scale Fuel Cell Generation System (대용량 연료전지발전시스템의 계통외란방지알고리즘에 관한 연구)

  • Kim, Gi-Young;Oh, Yong-Taek;Kim, Byung-Ki;Kang, Min-Kwan;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5550-5558
    • /
    • 2015
  • Recently, fuel cell with high energy efficiency and low CO2 emission is energetically interconnected with power system. Especially, FCGS(Fuel Cell Generation System) which usually operates at high temperature, is being developed and installed in the form of large scale system. However, it is reported that power system disturbances related to surge, harmonic and EMI have caused several problems such as malfunction of protection device and damage of control device in the large scale FCGS. In order to solve these problems, this paper presents a modeling of operation characteristics of FCGS by PSCAD/EMTDC, ETAP, P-SIM software. And also, this paper proposes countermeasure algorithms to prevent power system disturbances. From the simulation results, it is confirmed that the proposed algorithm is useful method for the stable operation of large scale FCGS.