• 제목/요약/키워드: SOIL PROFILE

검색결과 489건 처리시간 0.035초

프로브형 가시광-근적외선 센서를 이용한 토양의 탄소량 측정 (Soil Profile Measurement of Carbon Contents using a Probe-type VIS-NIR Spectrophotometer)

  • 권기영
    • Journal of Biosystems Engineering
    • /
    • 제34권5호
    • /
    • pp.382-389
    • /
    • 2009
  • An in-situ probe-based spectrophotometer has been developed. This system used two spectrometers to measure soil reflectance spectra from 450 nm to 2200 nm. It collects soil electrical conductivity (EC) and insertion force measurements in addition to the optical data. Six fields in Kansas were mapped with the VIS-NIR (visible-near infrared) probe module and sampled for calibration and validation. Results showed that VIS-NIR correlated well with carbon in all six fields, with RPD (the ratio of standard deviation to root mean square error of prediction) of 1.8 or better, RMSE of 0.14 to 0.22%, and $R^2$ of 0.69 to 0.89. From the investigation of carbon variability within the soil profile and by tillage practice, the 0-5 cm depth in a no-till field contained significantly higher levels of carbon than any other locations. Using the selected calibration model with the soil NIR probe data, a soil profile map of estimated carbon was produced, and it was found that estimated carbon values are highly correlated to the lab values. The array of sensors (VIS-NIR, electrical conductivity, insertion force) used in the probe allowed estimating bulk density, and three of the six fields were satisfactory. The VIS-NIR probe also showed the obtained spectra data were well correlated with nitrogen for all fields with RPD scores of 1.84 or better and coefficient of determination ($R^2$) of 0.7 or higher.

실시간 포장에서 측정한 토양 경도 및 전자장 유도 전기전도도와 작물수량과의 관계 (Relationship of soil profile strength and apparent soil electrical conductivity to crop yield)

  • 정원교
    • 한국토양비료학회지
    • /
    • 제39권2호
    • /
    • pp.109-115
    • /
    • 2006
  • 점토경반층 토양에서 수량 변이의 특성을 파악하기 위하여 센서를 통하여 관측된 깊이별 토양경도 및 ECa와 작물의 수량과의 관련성을 분석한 결과, 깊이별 토양의 경도는 점토가 집적된 지표면으로부터 15-30 cm 지점의 점토경반층 (argillic horizon)에서 높게 나타내고 있으며 토양의 깊이가 깊은 지점에서 토양경도의 변이가 작게 나타났다. 1994년부터 2002년까지 콩과 옥수수 수량과 작물생육기의 강우량을 분석한 결과 7-8월의 강우량이 작물의 수량과 매우 밀접한 관계를 가지고 있으며 이 기간의 강우량이 150 mm 이하이면 작물이 수분 부족으로 수량이 낮아지는 것으로 나타났다. 지표로부터 15-45 cm 지점에서 토양의 경도와 ECa 가 작물의 수량과 매우 유의한 상관을 갖는 것으로 나타났으며 "drought boundary" 인 7-8월의 강우량이 150 mm를 기점으로 각기 반대의 상관을 보이는 것으로 나타났다. 측정된 토양의 깊이별 경도 값과 ECa 를 이용하여 수량 추정식을 계산 하였으며 추정식의 검증을 위하여 별도의 독립적인 자료를 이용하여 추정된 수량과 측정된 수량의 표준오차를 비교한 결과 측정된 수량에 대한 표준오차의 비율이 4-16% 로 나타났으며 7-8월의 강우량이 150 mm 이하로 건조한 경우에 표준오차가 같은 시기에 강우량이 150 mm 이상으로 습윤한 경우보다 현저하게 표준오차가 크게 나타났다. 결론적으로 신속하고 경제적으로 이용할 수 있는 센서 측정자료와 작물수량과의 관련성을 분석한 결과, 연구에 이용된 점토경반층 토양에서 센서를 이용하여 측정한 ECa 및 깊이별 토양경도와 작물 수량간에 통계적으로 유의한 상관이 있음을 알 수 있다.

CPT-based lateral displacement analysis using p-y method for offshore mono-piles in clays

  • Kim, Garam;Park, Donggyu;Kyung, Doohyun;Lee, Junhwan
    • Geomechanics and Engineering
    • /
    • 제7권4호
    • /
    • pp.459-475
    • /
    • 2014
  • In this study, a CPT-based p-y analysis method was proposed for the displacement analysis of laterally loaded piles. Key consideration was the continuous soil profiling capability of CPT and cone resistance profiles that do not require artificial assumption or simplification for input parameter selection. The focus is on the application into offshore mono-piles embedded in clays. The correlations of p-y function components to the effective cone resistance were proposed, which can fully utilize CPT measurements. A case example was selected from the literature and used to validate the proposed method. Various parametric studies were performed to examine the effectiveness of the proposed method and investigate the effect of property profile and its depth resolution on the p-y analysis. It was found that the calculation could be largely misleading if wrongly interpreted sub-layer condition or inappropriate resolution of input soil profile was involved in the analyses. It was also found that there is a significant influence depth that dominates overall load response of pile. The soil profile and properties within this depth range affect most significantly calculated load responses, confirming that the soil profile within this depth range should be identified in more detail.

콘관입시험결과를 이용한 흙분류차트의 적용성에 관한 연구 (Study on the Applicability of CPT Based Soil Classification Chart)

  • 김찬홍;임종철;김영상
    • 대한토목학회논문집
    • /
    • 제28권5C호
    • /
    • pp.293-301
    • /
    • 2008
  • 지반을 대상으로 하는 일련의 활동에서 지층의 구성에 관한 정보는 필수적인 요소이다. 일반적으로 시추를 통해 지층 구성을 알 수 있으나, 배출되는 작업수와 슬라임, 굴진속도, SPT 시료 등을 참고하여 작성되는 다소 경험적인 면이 있다. 더욱이 최근 시추장비의 고성능화로 인해 얇은 토사층의 경우 구분이 점점 어려워지고 있는 것이 현실이다. 피에조콘관입시험은 주로 점토층을 대상으로 시행되었으나 최근 모래층 및 실트층으로 사용이 확대되고 있는 실정이다. 연속적인 데이터를 확보할 수 있다는 이점이 있어 흙분류에 적용하기 위한 연구가 많이 진행되었고 다양한 도표가 제안되어 사용되고 있다. 하지만, 국내에서는 이에 대한 검증 없이 적용하고 있는 것이 현실이며, 이에 대한 검증을 바탕으로 국내지반과 현실에 맞는 새로운 흙분류 시스템의 개발이 필요한 실정이다. 본 연구에서는 국내 17개 지역에서 수행된 피에조콘 관입시험 결과와 채취된 시료들에 대한 흙분류 결과를 데이터베이스화하였고, 피에조콘 결과를 이용하도록 제안된 국 내외 흙분류차트 7종류들의 국내지반에 대한 적용성을 토질 종류별로 검토하였다. 또한 종합적으로 국내지반의 흙분류에 가장 적합한 흙분류차트와 사용 변수들을 도출하였고 선정된 도표의 영역별 설명과 국내 기술자들에게 익숙한 통일분류결과와의 상관성에 대하여 고찰하였다.

특정지반에 적용할 설계응답스펙트럼에 대한 고찰 (A Study on the Applicatin of Design Response Spectrum to a Specific Soil Profile)

  • 박형기
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.91-99
    • /
    • 2001
  • This paper is for a reasonable selection of design response spectra for the seismic design of specific types of soil-structure interaction systems, e.g., underground structure within flexible soil profiles of structures on the shallow soil layers on the stiff bed rock. the existing backup data used for determining the design response spectra of the Code have been investigated and evaluated. For this purpose, various types of free field analyses have been performed using one-dimensional wave propagation theory considering the nonlinear properties of the soil profile. As a result, a reasonable approach of determining input response spectra for specific soil profiles has been proposed to be compatible to the design response spectra of the Code.

  • PDF

남부지역 골프장의 토양단면 특성 (Soil Profile Characteristics of Coif Courses Located in Southern Region)

  • 최병주;주영희;심재성
    • 아시안잔디학회지
    • /
    • 제9권1호
    • /
    • pp.75-80
    • /
    • 1995
  • In eight golf courses of southern area fair way soil profile was investigated for soil physical, chemical properties, and root distribution. These were carried out only A horizon(lScm depth) in one golf course. Soil series was all different, Leaching to lower horizon was greator in order of Mg=$NO_3$> $NH_4$=Ca> K. Organic matter content was higher in B horizon than A in three golf courses. Soil phosphorus appeared to more down greatly in two golf courses. Soil pH was higher in lower horizon of all places. Such pH increase with depth seemed to he related with mineral leaching, Among the horizons of all golf courses BC showed significant correlation with K (EC =0.1025K +0.0157, r=0. 8012 p=0. 001 n=20). Both Fe and Mn were higher in A horizon.

  • PDF

원심 모형 시험을 위한 동적 현장 지반 모사 기법 연구(대만 화련 지반) (Simulation of Dynamic in-situ Soil Properties for the Centrifuge Test (Hualien Site in Taiwan))

  • 하정곤;이세현;추연욱;김세희;김동수
    • 한국지진공학회논문집
    • /
    • 제16권4호
    • /
    • pp.27-36
    • /
    • 2012
  • 본 연구는 원심 모형 시험을 위한 동적 현장 지반의 모사 기법을 제안하였다. 현장지반 모사를 위해서 현장 지반의 층상 구조 및 전단파 속도 주상도에 대한 자료를 바탕으로 모형시료를 조성하고, 구속압 별 공진주 시험을 수행하였다. 그리고 공진주 시험을 통하여 지반의 특성계수와 구속압 영향계수를 구하고, 모형 지반의 전단파 속도를 예측하였다. 이를 현장의 전단파 속도 주상도와 비교하여 시료 조건을 결정하였다. 그리고 결정된 시료 조건을 바탕으로 원심모형시험 모델을 제작하고, 인-플라이트 상태에서 벤더 엘리먼트 시험을 수행하여 제안된 기법의 타당성을 검증하였다. 그리고 대형지진시험이 수행된 적이 있는 대만 화련의 현장 지반을 대상으로 축소 모델링 기법을 적용하였다.

지중강판 구조물의 최소토피고 평가 및 상부토피 보강 방안 (Evaluation of minimum depth of soil cover and reinforcement of soil cover above soil-steel bridge)

  • 정현식;이종구;조성민;김명모
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.425-432
    • /
    • 2004
  • In this paper, the results of the numerical analysis for the minimum depth of soil cover have been compared with those of currently suggested codes. Based on this comparison, the minimum depth of soil cover for the structures with long spans was suggested. Results showed that the actual depth of the soil cover required against soil failure over a circular and low-profile arch structure does not vary significantly with the size of the span and for the circular structure, the minimum depth of the soil cover was about 1.5m, and for the low-profile arch structures, below about 1.6m. And the previously established code in which the minimum depth of soil cover is defined to linearly increase with the increase in the span (CHBDC, 2001) was very conservative. For the structure with the relieving slab, the maximum live load thrust was reduced by about 36 percent and the maximum moment about 81 percent. The numerical analysis gave more conservative estimation of the live-load thrusts than the other design methods.

  • PDF

Characterization of Cone Index and Tillage Draft Data to Define Design Parameters for an On-the-go Soil Strength Profile Sensor

  • Chung S. O.;Sudduth Kenneth A.
    • Agricultural and Biosystems Engineering
    • /
    • 제5권1호
    • /
    • pp.10-20
    • /
    • 2004
  • Precision agriculture aims to minimize costs and environmental damage caused by agriculture and to maximize crop yield and profitability, based on information collected at within-field locations. In this process, quantification of soil physical properties, including soil strength, would be useful. To quantify and manage variability in soil strength, there is need for a strength sensor that can take measurements continuously while traveling across the field. In this paper, preliminary analyses were conducted using two datasets available with current technology, (1) cone penetrometer readings collected at different compaction levels and for different soil textures and (2) tillage draft (TD) collected from an entire field. The objective was to provide information useful for design of an on-the-go soil strength profile sensor and for interpretation of sensor test results. Analysis of cone index (CI) profiles led to the selection of a 0.5-m design sensing depth, 10-MPa maximum expected soil strength, and 0.1-MPa sensing resolution. Compaction level, depth, texture, and water content of the soil all affected CI. The effects of these interacting factors on data obtained with the soil strength sensor should be investigated through experiments. Spatial analyses of CI and TD indicated that the on-the-go soil strength sensor should acquire high spatial-resolution, high-frequency ($\ge$ 4 Hz) measurements to capture within-field spatial variability.

  • PDF