Proceedings of the Korean Vacuum Society Conference
/
2013.02a
/
pp.339-339
/
2013
We study on the optical and electrical properties of indium-free ZTO(ZnSnO)/Ag/ZTO (ZAZ) multilayer electrodes for the low-cost transparent electrode. In the first step, each single layer was deposited using rf magnetron in-line sputter with various working pressure based on $O_2$/$Ar+O_2$ ratio (0~3%) and power at room temperature. Secondly, we studied the optical and electrical properties by analyzing the refractive index, extinction coefficient, transmittance and resistivity of each layer. Finally, we optimized the thickness of each layer using macleod simulation program based on the analyzed optical properties and fabricated the multilayer electrode. As a result, We achieved a low sheet resistance of $11{\Omega}$/sq and anaverage transmittance of 80% in the visible region of light (380~780 nm). This indicates that indium-free ZAZ multilayer electrode is a promising low-cost and low-temperature processing electrode scheme.
New ITO thin film of good performance has been developed by brand-new, plasma-damage-free sputtering process at the room temperature. The room temperature-processed ITO films with optimized conditions as neutral beam acceleration bias of -30V and In & Sn composition ratio of 99:01 gives lower resistivity as $4.22{\times}10^{-4}{\Omega}-cm$ and higher transmittance over 90% a wavelength of 550 nm. The transmission electron microscope (TEM) images of the films show a nano-crystalline structure.
In the single sweep record of event-related potential (ERP), the peak latency of P300, which is one of the most prominent positive peaks in the ERP record, might fluctuate according to the recording conditions. The fluctuation of the peak latency (measurement fluctuation) is the summation of the fluctuation caused by physiological factor (physiological fluctuation) and one by noise of background EEG (noise fluctuation). We propsed a method for estimating the interval of the physiological fluctuation based on a limited number of single sweep records. The noise fluctuation was estimated by using the relationship between the signal-to-noise (SN) ratio and the noise fluctuation based on the P300 model and the background EEG model. The interval estimate of the physiological fluctuation were obtained by subtracting the interval estimate of the noise fluctuation from that of the measurement fluctuation. The proposed method was tested by using simulation data of ERP and applied to actual ERP and data of normal subjects, and gave satisfactory results.
The purpose of this study was to evaluate the initial skeletal pattern and growth change of whom had responsed well to chincap therapy. 93 patients seleted for this study were in mixed dentition and treated with chincap for more than 2 years. And 54 subjects were selected from these total samples and classified into two groups by the improvement of four measurements : ANB difference, APDI, Wits appraisal, and AF-BF. One was good response group which consisted of 26 children and the other was poor response group with 19 patients. Various measures of the craniofacial structure in the initial lateral cephalograms and the annual increments were calculated and analyzed by comparing two groups with t-test. The results were as follows : 1. Good response group had more horizontal growth pattern in initial stage of treatment than poor response group, and the contributing factors of this result were anterior posterior facial height ratio, gonial angle, lower genial angle and SN-mandibular plane angle. 2. The maxilla was positioned more anteriorly in good response group. 3. The amounts of vertical growth of maxilla was smaller but the horizontal growth of maxilla was larger in good response group. 4. The mandible rotated more infero-posteriorly in good response group. 5. The good response group had more vertical growth pattern of mandibular condyle.
In order to know the variation of the associated craniofacial skeletal angle and linear distance according to the change of gonial angle, the roentgenographic cephalo metric study was undertaken in Korean normal cephalometric analysis and eletric computer. The fallowing results were optained. 1) The size of gonial angle is mainly depend on the lower gonial angle. The mean of upper gonial gngle is almost same in normal occlusion group$^*$ and malocclusion group. 2) It was resulted on normal group and malocclusion group by F test that the number of parameters that were significant at 5% level of confidence were 14 parameters in normal occlusion group and 22 parameters in malocclusion group. 3) Ramus height and mandibular body length increased and facial ratio is decreased as gonial angle decreased. 4) MP-T, overbite depth and Y-axis angle is not related to gonial angle in normal occlusion group, but in moloclusion group, as gonial angle decreased, MP-T and overbite depth is increased and Y-axis angle is decreased. 5) SN-MP, OP-MP, PP-MP is increased as gonial anglel increased, it was mainly depend on the lower gonial angle.
Moon, Young Kook;Shin, Min Sung;Jo, Young-Moo;Lim, Kyeorei;Lee, Jong-Heun
Journal of Sensor Science and Technology
/
v.27
no.4
/
pp.221-226
/
2018
Misfueling accidents significantly damage the engines of both gasoline and diesel vehicles, and should be avoided by rapid and accurate fuel discrimination. Gasoline fuel contains bioethanol. Thus, the detection of ethanol vapor produced by gasoline can be used to distinguish between gasoline and diesel. In the present study, Pt-doped $SnO_2$ hollow nanospheres, Mg-doped $In_2O_3$ hollow microspheres, and Pt-doped ZnO nanostructures have been used as gas sensors to discriminate between gasoline and diesel fuels. All three sensors are able to detect and discriminate between gases evaporating from gasoline and diesel. Among the sensors, the Mg-doped $In_2O_3$ hollow microspheres show a significant gas response (resistance ratio = 4.97) quickly (~3 s) after exposure to gasoline-evaporated gas at $225^{\circ}C$, but did not show any substantial response to diesel-evaporated gas. This demonstrates that gasoline and diesel fuels can be discriminated using small and cost-effective oxide semiconductor gas sensors.
Journal of the Korean institute of surface engineering
/
v.44
no.6
/
pp.260-263
/
2011
GZO/ITO double layered films were deposited on unheated non-alkali glass substrates by RF magnetron sputtering using an ITO ($SnO_2$: 10 wt%) and GZO($Ga_2O_3$: 5.57 wt%) ceramic targets, respectively. The electrical resistivity of GZO/ITO films depends on the thickness ratio between the GZO film and ITO film. With increasing ITO film thickness, the resistivity of GZO/ITO films decreased which due to large increase in the Hall mobility. Also, the crystallinity of GZO/ITO film was improved with an increase in ITO thickness which was evaluated by X-ray diffraction. The average transmittance of the films was more than 85% in the visible region, which is slightly higher than ITO single layer films.
Purpose: This study attempts to find out the optimum condition of the rotary cutter making pellet in the footwear outsole process. The pellets are used in the process of outsole rubber fabrication to reduce cycle time and save raw material. Methods: Computer simulations are used to analyze the maximum stress in the rotary cutter after designing a variety of cutter shapes. Taguchi method is used to identify the robust condition of the cutter. In $L_{18}$ orthogonal array, the control factors such as knife width, twisted angle, number of knives, diameter, knife depth and supported angle are considered and noise factors like assembly tolerance and amount of antifriction are allocated. Results: It is found that the most important factors to reduce maximum stress in the cutter are supported angle and diameter. Using Tacuchi's results, we can reduce 70% cycle time and 9% raw material compared to the traditional method using cutting die. Conclusion: When designing the rotary cutter, the best conditions are the diameter at its maximum allowable value and supported angle in the boundary of machine inner space.
Purpose: The purpose of this paper is to show whether the results are changed with respect to the variance of the data, by analysis of data obtained from the Taguchi experimental techniques and general experiment. Because which cannot be prove by mathematical Formula, through experimental examples will show. Methods: Taguchi experiments were carried out with paper Helicopter experiment. Experimental Data are obtained by special designed Drop Test Equipment. While Experimental value arbitrarily changed, we looked at how Significant control Factor of Taguchi Methods and Factor experiments are changed. This process cannot be expressed as a Mathematical formula, but showed as a numerical example. Results: Saw significant changes in the factors when data is outside a certain range of the experimental data. By Test of Equivalence Variance, Experiment data is verified reliability. To find the Control Factor, Taguchi Method is better than the general experiment. Conclusion: We know that a Significant Factor is changed with the range of Variance of Experiment Data. The value of this paper is verified change process with Numerical Data obtained Experiment.
Kim, Na-Hyung;Park, Hyo-Min;Chung, Soo-Yeon;Go, Eun-Jung;Lee , Hwa-Jeong
Archives of Pharmacal Research
/
v.27
no.12
/
pp.1263-1269
/
2004
The objective of this study was to characterize immunoliposomes carrying plasmid DNA with optimal encapsulation efficiency and antibody density. Plasmid DNA was encapsulated by the freezing/thawing method into liposomes composed of POPC (1-palmitoyl-2-oleoyl-sn-glycerol- 3-phosphocholine), DDAB (didodecyl dimethyl ammonium bromide), DSPE-PEG 2000 (distearoyl phosphatidyl ethanolamine polyethylene glycol 2000) and DSPE-PEG 2000-maleimide. The liposomes carrying plasmid DNA were extruded through two stacked polycarbonate filters, of different pore size, to control the liposome size. Then, rat IgG molecules were conjugated to the liposomes. The immunoliposomes containing plasmid DNA were separated from the free plasmid DNA and unconjugated IgG by Sepharose CL-4B column chromatography. The DNA amount encapsulated was affected by DDAB (cationic lipid) concentration, the initial amount of plasmid DNA between 10 ${\mu}g$ and 200 ${\mu}g$, the total lipid amount and plasmid DNA size, but not significantly by liposome size. By varying the ratio of DSPE-PEG 2000-maleimide to IgG, the number of IgG molecules per liposome was changed significantly.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.