• Title/Summary/Keyword: SMOKE 측정

Search Result 239, Processing Time 0.026 seconds

A Toxicity Evaluation for the Toxic Gases of Building Finish Materials (건축물 마감재료 연소가스에 의한 독성평가)

  • Cho, Nam-Wook;Cho, Dong-Ho;Oh, Eun-Ha
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.129-140
    • /
    • 2012
  • Smoke toxicity is the test for the toxicity evaluation of smoke and hazardous gas, caused by combustion of building materials and finishing materials. Smoke toxicity can be evaluated by the mean incapacitation time of mice. This test result can be influenced by the health status of mice and test condition. In acute inhalation toxicity test of hazardous gas, no typical clinical findings and histopathologic abnormalities were observed. Tracheitis and bronchitis as well as acute lung inflammation around terminal bronchiole in some mouse of the highest dose group. Through this study, we established the method for inhalation toxicity test of hazardous gas as well as the SOP of inhalation toxicity test. However, in the future studies, the concentration control methods for inhalation technologies on hazardous gas will be needed to improve continuously and also further studies on other gas inhalation toxicity will be needed to conduct.

Measurement of Environmental Tobacco Smoke in the Air of Offices in Urban Areas - Focusing on the Impact of Smoking on the Concentrations of Suspended Particles - (도시지역 사무실내 공기 중 환경담배연기의 측정 - 흡연이 부유먼지 농도에 미치는 영향을 중심으로 -)

  • Baek Sung-Ok;Park Sang-Kon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.6
    • /
    • pp.715-727
    • /
    • 2004
  • This study was carried out to evaluate non-smoker's exposure levels to environmental tobacco smoke (ETS) in the air of offices in urban areas. A total of 65 offices were selected from two large cities, i.e. Daegu and Daejeon. The field sampling was conducted repeatedly in summer (1999) and winter (1999~2000). The measured ETS markers included respirable suspended particles (RSP as PM$_{40}$ ), vapor and particulate phase ETS markers, including nicotine, 3-ethnyl pyridine (3-EP), ultraviolet absorbing particulate matter (UVPM), fluorescing particulate matter (FPM), and solanseol in ETS particles (SolPM). RSP was measured gravimetrically by a microbalance. The particle samples were then used for the determination of particulate ETS markers by HPLC, while vapor phase markers determined by GC/NPD. The analytical methods were validated for repeatability, linearity, detection limits, and duplication precision. The concentrations of RSP and other ETS markers were significantly higher in smoking offices than non-smoking offices. Despite the similar smoking strength in each office for different seasons, the concentration levels of ETS components appeared to be higher in winter than summer. The contributions of ETS to RSP concentrations based on SolPM, FPM, and UVPM methods were estimated to be in the range of 15.2 ~ 25.3% in smoking offices, whereas 2.4 ~ 15.9% in non-smoking offices. The cooling and heating types did not affect significantly the concentrations of RSP and other ETS markers. Finally, further research issues were suggested to obtain more scientific information on the non-smoker's exposure to ETS with respect to the frame of risk assessment..

A Comparative Study on Toxic Gas Index and Stop Time of Mouse Activity (연소독성지수와 마우스 행동정시시간 비교 연구)

  • Cho, Nam-Wook;Lee, Jong-Cheon;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.35-41
    • /
    • 2011
  • Casualties due to toxic smoke products have been reported as major fire damage. There are various tests in order to evaluate toxic smoke from a fire at home and abroad, and KS F 2271 as a test of the gas hazard of building finish materials has been conducted in Korea. The current test of the gas hazard exposes rodent, laboratory rat, to smoke gases to evaluate combustion gas toxicity by measuring acting time of that. this study performed a test of the gas hazard for combustible polymer material, Urethane and rubber flooring, and determined gases with the FT-IR. Quantitative results compared with standard value defined in BS6853 and toxicity index (R) was calculated. Using relative comparison with animal test and the toxicity index, We tried a variety of toxicity evaluation by correlation analysis of two tests.

Combustion Chracteristics of the Pinus rigida and Castanea savita Dried at Room Temperature (실온에서 건조된 리기다 소나무와 밤나무의 연소특성)

  • Chung, Yeong-Jin;Jin, Eui
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.86-92
    • /
    • 2010
  • One of the limitation of wood as building materials is its flammability. The purpose of this paper is to examine the combustion properties of the Pinus rigida and Castanea savita which are grown in Korea and meet the desirable characteristics for use of construction materials. The cone calorimeter (ISO 5660-1) was used to determine the heat release rate (HRR) and fire smoke index, as well as CO and $CO_2$ production and smoke obscuration. The $HRR_{mean}$ of the Castanea savita and Pinus rigida at $50\;kW/m^2$ of radiant heat flux was $70.4\;kW/m^2$ and $68.5\;kW/m^2$. Furthermore, the THR of Castanea sativata was 120.8 MJ/kg and it was higher than the THR of Pinus rigida ($81.9\;MJ/m^$). These results are depend on the bulk density of tested wood species. The Castanea savita has high $CO_{mean}$ yield and high CO/$CO_2$ yield compared with that of Pinus rigida.

Numerical Analysis on Flow Characteristics in the Pressurized Air Supply Smoke Control System (급기가압 제연설비의 내부 유동특성에 대한 수치해석)

  • Ko, Gwon-Hyun
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.52-58
    • /
    • 2017
  • This study investigated the pressure difference distribution and the flow characteristics among room, ancillary room, and stair case by carrying out the numerical simulations on the air flow inside the pressurized air supply smoke control system. Numerical simulations were conducted to analyze pressure and velocity distribution of compartments by pressurized air supply for the air-leakage test facility which was built to measure the effective leakage area. In this study, the leakage of air was considered by locating the narrow slit onto fire door and window of room. Simulated results using this method precisely followed the previous experimental results for the pressure differences between the stair case and ancillary room. Predicted results showed that the local leakage of air rarely affected the overall flow pattern and pressure distribution. Although the average velocity over the door between room and ancillary room satisfied the regulation for fire safety, it was certified the unsafe outflow to ancillary room could be occurred in the local position such as the upper part of the door.

A Study on the Pressure Change during the Pressurization to the Elevator Lobby (부속실 급기가압 시 압력특성 변화에 관한 연구)

  • Kim, Beom-Kyue;Park, Yong-Hwan;Kim, Hong-Sik
    • Fire Science and Engineering
    • /
    • v.26 no.5
    • /
    • pp.99-104
    • /
    • 2012
  • This study investigated the pressure change in the fire room and elevator lobby during the air pressurization to the Elevator lobby with the various egress scenarios and the existence of vent holes in the fire room. The experiments revealed that pressure change was significantly affected by the open/closure scenarios of the front door and stairway door resulting in over pressure, under pressure and performance drop of the door closure. It also revealed that the required smoke defensive air velocity can be obtained only with the existence of vent holes in the fire room by the removal of back pressure in the fire room.

The Experimental Study on the Toxic Gases Released from the Floor Finishing Materials in Entertainment Service Industry Buildings (다중이용시설 바닥마감재의 연소가스 독성평가에 관한 실험 연구)

  • 강성동;이창우;현성호;윤명오
    • Fire Science and Engineering
    • /
    • v.16 no.2
    • /
    • pp.14-21
    • /
    • 2002
  • The several floor finishing materials that widely used in entertainment service industry buildings were evaluated according to the method of NES 713. Also, toxic gases of floor finishing materials in combustion without air flow rate were checked as concentration of fire gases variation according to time using gas analyzer. We had estimated the smoke hazard of floor finishing materials in fire. As results of gas analyses using the method of NES 713, toxic index of samples was estimated range of 2~9.7. Therefore, a large amount of toxic gases will release from a floor finishing materials fire and connoted great smoke hazard in fire.

Fatigue by Analyzing Heart Rate Variability and Its Association Factors among Workers in the same industry (심박변이도 측정을 통한 피로요인 분석 : 동일 사업장의 근로자 대상으로)

  • Jung, Hyun-Jung;Kim, Seung-Mo;Back, Young-Doo
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.19 no.2
    • /
    • pp.67-74
    • /
    • 2015
  • Objective : The aim of this study was to investigate fatigue-related factors including socio-demographic variables and life styles among workers in the automobile manufacturing industry. Method : The subjects were 22,937 individuals who had received health examination by Korean Medical doctors and responded to questionnaires for 8 months from March to November in 2011. The fatigue index was measured by heart rate variability (HRV) in an automobile manufacturing industry. A multivariate analysis with SPSS version 19.0 was used to examine the relationship between fatigue and other factors including ages, smoke consumption, drinking frequency, exercise frequency, occupational category, conjugal condition. Results : In comparison between normal and very bad level of fatigue, factors of ages, smoking, drinking, and exercise showed significant difference(p<0.05). In addition, when normal and bad fatigue were compared, ages, smoking, exercise also produced significant difference(p<0.05). Furthermore, in normal and good level of fatigue comparison, occupation and smoking yielded significant difference(p<0.05). Finally, in other comparisons between normal and very good fatigue, exercise, smoking and occupation revealed significant difference(p<0.05). Conclusion : The results of this study suggest that age increase affects fatigue negatively, whereas exercise and drinking of once or twice per a week can have positive correlations.

Applications of Satellite Imagery to Surveying Archeological Sites and Remains

  • Chin, Yong-Ok;Park, Kyoung-Yoon
    • Journal of Satellite, Information and Communications
    • /
    • v.2 no.2
    • /
    • pp.75-79
    • /
    • 2007
  • Satellite imagery was applied to locating archeological sites and remains around northeastern areas of China, called as Manchuria, and Korean peninsular, such as Mountain Fortress of Goguryeo Dynasty era($37BC{\sim}771AD$), and firing torch and smoke beacon signal sites at mountain tops in Josun Dynasty era($1392{\sim}1910AD$) as well as burial sites below the ground level in the modern era. Information on archeological sites, fire posts and burial places could be found in various literatures, but real figures of such cultural assets have been disappearing due to land development programs and human activities in recent years. Some of these historical sites were identified in satellite images using GPS(Geographical Positioning System). Real locations of these sites would be further necessary to be verified.

  • PDF

Experimental and Numerical Study of Smoke Movement in Tunnel Fires (터널 화재 시 연기전파에 대한 실물실험 및 수치해석적 연구)

  • Lee Seung-Chul;Lee Seung-Ho;Kim Nam-Young
    • 한국터널공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.341-347
    • /
    • 2005
  • 본 논문은 터널에서 화재 발생 시, 시간에 따른 연기거동에 대해 실물실험과 3차원 수치해석을 수행하고 각각의 결과를 비교,검토하였다. 실물실험을 위하여 8.8 kW의 열원과 901iter/h의 연기 발생이 가능한 연기발생장치를 자체 제작하였으며, 대상터널은 길이 570m, 단면적 $64.6m^2,$ 그리고 약 $2\%$의 구배를 가지고 있다. 실험은 외풍의 영향을 줄이기 위해 터널 입,출구에 차단막을 설치하였으며 연기발생장치로부터 20m 간격의 위치에서 20초 간격으로 연기전파, 속도 그리고 온도를 측정하였다. 연기는 60초 경과 후, 연기발생장치로부터 20m 떨어진 위치에 도달하였으며 140초, 180초 및 260초 경과 후, 각각 40m, 60m 및 80m 위치에 도달하였다. 3차원 수치해석의 결과는 터널벽면을 매끈한 표면으로 처리하였을 때, $26.3\~49.5\%$정도 과대 예측하였다. 또한 터널벽면을 일정 조도를 갖는 거친 표면으로 처리한 경우는 $-2.7\~17.6\%$ 오차로 실험결과에 보다 근접하는 결과를 보였다. 따라서 터널 내 연기거동에 대한 3차원 수치해석을 수행할 때에는 벽면조도에 대한 고려가 필요하리라 판단된다.

  • PDF