• Title/Summary/Keyword: SIL4

Search Result 1,658, Processing Time 0.029 seconds

Optical Performance Evaluation of SIL Assembly with Lateral Shearing Interferometer (층 밀리 간섭계를 이용한 고체침지렌즈의 광학적 성능 평가)

  • Lee, Jin-Eui;Kim, Wan-Chin;Choi, Hyun;Kim, Tae-Seob;Yoon, Yong-Joong;Park, No-Cheol;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.4
    • /
    • pp.224-229
    • /
    • 2006
  • There has been studied flow to minimize the spot size to increase data capacity. Optical data storage devices are being developed near practical limits with wavelength and NA of 405nm and 0.85. There has been studied many types of next generation storage devices such as blu-ray multilayer system, probe based data storage and holographic data storage. Among these data storage devices, solid immersion lens(SIL) based near field recording (NFR) has been widely studied. In this system, SIL is the key component that focuses the laser beam with a very small size which enables ultra high data capacity. Therefore, optical performance evaluation system is required for SIL assembly. In this dissertation, a simple and accurate SIL assembly measurement method is proposed with wedge plate lateral shearing interferometer(LSI). Wedge plate LSI is cheaper than commercialized interferometer, robust to the vibration and the moving distance for phase shifting is large that is order of micrometer. We designed the thickness, wedge angle, material, surface quality and wavelength of wedge plate as 1mm, 0.02degree, fused silica, lamda/10(10-5) and 405nm, respectively. Also, we confirmed simulation and experimental results with quantitative analysis. This simple wedge plate LSI can be applied to different types of SIL such as solid immersion mirror(SIM), hemispherical, super-hemispherical and elliptical SIL.

  • PDF

Synthesis of a Precursor of Bulgecinine, (4S,5R)-1-Acetyl-2-formyl-5-benzyloxymethyl-4-pyrrolidinol (Bulgecinine 선구물질인 (4S,5R)-1-Acetyl-2-formyl-5-benzyloxymethyl-4-pyrrolidinol의 합성)

  • Jeon, Hak Rim;Yoon, Shin Sook;Shin, Young Sook;Nam Shin, Jeong E.
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.3
    • /
    • pp.150-156
    • /
    • 1997
  • A precursor of bulgecinine, (4S,5R)-1-acetyl-2-formyl-5-benzyloxymethyl-4-pyrrolidinol (15) has been synthesized from diacetone-D-glucose. Barton deoxygenation, conversion to an L-sugar and displacement with $N_3^-$ at C-5, and one-pot reductive cyclization at C-2 produced (6R)-6-Ο-benzyloxymethyl-(3R)-3-methoxy-2-oxa-5-azabicyclo-[2,2,1]heptane(13), a key intermediate for bulgecinine. N-Acetylation and acid hydrolysis of 13 furnished a precursor of bulgecinine, (2S,4S,5R)-pyrrolidinol derivative 15 and its (2R,4S,5R)-diastereomer.

  • PDF

Comparison between Percoll and Sil-Select Methods on the Human Spermatozoa Treatment (인간정자의 처리에 있어서 Percoll과 Sil-Select 방법의 비교)

  • Moon, Shin-Yong;Ryu, Buom-Yong;Shin, Hyun-Ah;Oh, Sun-Kyung;Suh, Chang-Suk;Kim, Seok-Hyun;Choi, Young-Min;Kim, Jung-Gu;Choi, Kyu-Hong;Lee, Jin-Yong
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.27 no.4
    • /
    • pp.339-344
    • /
    • 2000
  • Objective: To evaluate silane-coated silica particles (Sil-select) as an alternative to polyvinylpyrrolidone-coated particles (Percoll) for gradient separation of spermatozoa, for use in assisted reproduction. Methods: 20 normal semen based on WHO criteria were included in this study. Recovery of motile and morphologically normal spermatozoa after using two-layer Percoll and Sil-select gradient respectively was recorded. Motility, HOST (hypoosmotic swelling test) and the detection of malondialdehyde for LPO (lipid peroxidation) after 24 h of incubation at $37^{\circ}C$ in a 5% $CO_2$ incubator were compared. Results: Percoll (78.5%) and Sil-select (79.1%) showed a significant increase in the motility compared to ejaculate (60.9%) but no difference between Percoll and Sil-select. Normal sperm morphology significantly increased after Percoll (57.6%) and Sil-select (53.7%) compared to ejaculate (35.8%) but no difference between Percoll and Sil-select. No differences in the recovery of motile spermatozoa and motility, HOST and the production of malondialdehyde after 24 h incubation were found when comparing the use of Percoll and Sil-select. Conclusion: Sil-select seems to be an attractive alternative to Percoll for sperm separation in assisted reproduction.

  • PDF

A Study on the Improvement of Information Security Management Condition Evaluation in Public Sector through the SCAP Analysis by NIST in U.S. (미(美) NIST 보안성 자동평가프로토콜(SCAP)분석을 통한 공공기관의 정보보안관리실태 평가제도 개선방안 연구)

  • Jee, Yoon Seok;Lee, Yong Suk;Yoon, Duck Jung;Shin, Yong Tae
    • Journal of Information Technology Applications and Management
    • /
    • v.26 no.4
    • /
    • pp.31-39
    • /
    • 2019
  • The 129 public institutions in Korea are subject to Information Security Management Condition Evaluation (ISMCE) as a part of the government management evaluation system by the Ministry of Economy and Finance. ISMCE is started in 2006 with the central government institutions, and applied to the all public institutions in 2009. This evaluation is annually conducted by the National Intelligence Service through the site visits, and the number of the evaluated institutions is increasing year by year. However, the process of ISMCE - identifying existing vulnerabilities in the information system - is conducted manually. To improve this inconvenience, this paper introduces the various evaluation system in the major countries, especially in the United States, and analyzes the Security Content Automation Protocol (SCAP) by NIST. SCAP is automation protocol for the system vulnerability management (in technical fields) and security policy compliance evaluation. Based on SCAP, this paper suggests an improvement plan for the ISMCE of Korea.

Robot Navigation Control Using EMG and Acceleration Sensor (근전도 센서와 가속도 센서를 이용한 로봇 이동 제어)

  • Rhee, Ki-Won;Kang, Hee-Su;You, Kyung-Jin;Shin, Hyun-Chool
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.4
    • /
    • pp.108-113
    • /
    • 2011
  • In this paper, we propose a new method for robot navigation control through EMG and acceleration sensors which is attached to wrist. The method can remote control with intuitive motion like driving a car. It decide to control whether or not through EMG signal processing. And motion inferring through signal processing from acceleration sensor. Inferred motion is mapped to control command such as 'Forward', 'Backward', 'Left', 'Right'. Accuracy of each motions are over 99%. Control is capable naturally without time delay. Entire system has been implemented and we verified its utility through demonstration.

An Empirical Study on the Watermark Inserting Location Selection in DCT Based Iris Image (DCT기반 홍채 영상 속 워터마크 삽입위치 선택에 대한 실증적 연구)

  • Choi, Jae-Gab;Moon, Ji-Hwan;Song, Nu-lee;Park, Jin-Ho;Kim, Gye-Young
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2019.05a
    • /
    • pp.653-656
    • /
    • 2019
  • 현대 사회에서의 생체인식 기술의 발전을 통해 홍채, 지분 등의 정보를 사용하여 사용자의 신원확인 등이 가능하게 되었으며, 생체정보의 유출/위조 방지에 대한 중요성이 높아지면서 관련 연구가 활발히 이루어 지고 있다. 본 논문에서는 홍체 전체의 이미지에 삽입하거나 동공의 중심에 가까운 DCT(Discrete Cosine Transform)영역에 삽입방법, 동공 중심과 눈매의 영역을 검출하여 거리 및 DC 계수를 통하여 삽입 위치를 선택하는 방법 등 홍채영상 속 워터마크를 삽입하여 유출/위조된 홍채 영상을 검출하는 방법에서의 워터마크 삽입위치에 관한 방법을 연구하고, CASIA Irisimage Database ver 4.0의 워터마크를 삽입하여 NC(Normalized Correlation)의 값을 비교하여 워터마크 삽입 실험을 검증하였다.

Case Study on the Assessment of SIL Using FMEDA (FMEDA 기법을 적용한 SIL 등급 판정에 관한 사례연구)

  • Kim, Byung Chul;Kim, Young Jin
    • IE interfaces
    • /
    • v.25 no.4
    • /
    • pp.376-381
    • /
    • 2012
  • As the number, complexity and interaction of electrical, electronic and programmable electronic (E/E/PE) systems increase, a growing emphasis has been placed on the concept of functional safety during product development. IEC 61508 provides guidelines and standardized procedures in the development of reliable and dependable E/E/PE systems to assure functional safety. Determining risk classes (i.e., safety integrity levels, SILs) associated to a specific E/E/PE item may be recognized as one of the most crucial activities in the product development per IEC 61508 since SILs are used to specify necessary safety requirements for achieving an acceptable residual risk. This article presents a case study on the assessment of SILs applying failure modes, effects and diagnostic analysis (FMEDA) from which failure rates may be derived for each important failure category by combining a standard FMEA with online diagnostic techniques.

A Study on Architecture Design of Power Supply for SIL4 Safety Related System (SIL4 안전관련 시스템에 적합한 전원장치의 구조 설계에 대한 연구)

  • Yoo, Deung-Ryeol;Lee, Key-Seo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.9
    • /
    • pp.1001-1008
    • /
    • 2015
  • This paper introduces the architecture of the power supply in order to achieve the safety integrity target for power supply which is a part of safety related system. The integrity level for safety is set 4 and according to the IEC 62425 which is standard for railway application the architecture design is conducted and process for design is developed. The procedure for design consists with 6 steps. The architecture of power supply that is able to keep the safety integrity against of failure of power supply is derived through the analysis and it is suggested that the power supply adopted the result in this paper is suitable to apply in safety system. Also, the failure frequency that is a quantitative value for the power supply is proposed.

철도분야에 적합한 SIL 4 자동화 솔루션, 필츠 PSS 4000-R

  • Go, Seol-Rin
    • Railway Journal
    • /
    • v.18 no.5
    • /
    • pp.29-32
    • /
    • 2015
  • PSS 4000과 같이 표준화된, 또한 사용이 쉬운 자동화 시스템은 사용자들의 초기 투자 비용은 물론 운영 비용도 감소시킬 수 있습니다. PSS 4000-R은 철도 분야 관련 승인이 된 제품이기 때문에 인증 작업량도 상당 부분 줄일 수 있습니다. PSS 4000-R은 같은 제품을 다양한 아키텍처로 구성하여 원하는 안전 무결성 등급(SIL 2, 3, 및 4)을 만족할 수 있습니다. 이러한 어플리케이션은 철도 건설 장비는 물론 레벨 크로싱 신호 감시와 같은 신호 제어 부분에도 사용될 수 있습니다. 각 프로젝트에 적용될 다양한 조건들을 손쉽게 적용 가능함 물론 복잡한 인증 업무도 파격적으로 줄여 줄 수 있는 PSS 4000-R 솔루션은 사용자에게 엄청난 비용절감 효과를 안겨 줄 것입니다.