Case Study on the Assessment of SIL Using FMEDA  

Kim, Byung Chul (Department of Automotive Engineering, Hanyang University)
Kim, Young Jin (Department of Systems Management and Engineering, Pukyong National University)
Publication Information
IE interfaces / v.25, no.4, 2012 , pp. 376-381 More about this Journal
Abstract
As the number, complexity and interaction of electrical, electronic and programmable electronic (E/E/PE) systems increase, a growing emphasis has been placed on the concept of functional safety during product development. IEC 61508 provides guidelines and standardized procedures in the development of reliable and dependable E/E/PE systems to assure functional safety. Determining risk classes (i.e., safety integrity levels, SILs) associated to a specific E/E/PE item may be recognized as one of the most crucial activities in the product development per IEC 61508 since SILs are used to specify necessary safety requirements for achieving an acceptable residual risk. This article presents a case study on the assessment of SILs applying failure modes, effects and diagnostic analysis (FMEDA) from which failure rates may be derived for each important failure category by combining a standard FMEA with online diagnostic techniques.
Keywords
functional safety; IEC 61508; safety integrity level (SIL); FMEDA; reliability prediction;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Bukowski, J. V. and Goble, W. M. (2012), Properly Assessing Mechanical Component Failure Rates, In Proceedings of Reliability and Maintainability Symposium (RAMS), Reno, NV, USA.
2 Bukowski, J. V. and Goble, W. M. (2009), Validation of a Mechanical Component Constant Failure Rate Database, In Proceedings of Reliability and Maintainability Symposium (RAMS), Fort Worth, NV, USA.
3 Catelani, M., Ciani, L., Luongo, V., and Singuaroli, R. (2010), Evaluation of the Safe Failure Fraction for an Electromechanical Complex System : Remarks about the Standard IEC 61508, In Proceedings of Instrumentation and Measurement Technology Conference, Austin, TX, USA.
4 Glotzner, T. (2008), IEC 61508 Certification of a Code Generator, In Proceedings of IET International Conference on System Safety, Birmingham, UK.
5 Goble, W. M. and Bukowski, J.V. (2007), Development of a Mechanical Component Failure Database, In Proceedings of Reliability and Maintainability Symposium (RAMS), Orlando, FL, USA.
6 IEC 61508, Functional Safety-Electric/Electronic/Programmable Electronic Safety-Related Systems, 2010.
7 Karou, S. (2005), EJX Series of IEC 61508 Safety Standard-Compliant Differential Pressure Transmitter, Yokogawa Technical Report, 40, 51-54.
8 Xie, Y., Li, J., and Zhang, A. (2011), Extended FMEA Method Applied in the Field of Functional Safety, In Proceedings of International Conference on Reliability, Maintainability and Safety (ICRMS), Guiyang, China.