• 제목/요약/키워드: SHEAR STRENGTH

검색결과 5,534건 처리시간 0.032초

반복하중을 받는 철근콘크리트 전단벽체의 접합방식에 따른 구조성능 평가 (Structural Performance Evaluation of Reinforced Concrete Shear Walls with Various Connection Type Under Load Reversals.)

  • 신종학;하기주;권중배;전찬목
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.513-518
    • /
    • 1997
  • In this study, nine reinforced concrete infilled frames involved bare frames were tested during vertical and cyclic loads simultaneously. This test programs were carried to investigate the horizontal strength and the crack propagation in variance with hoop reinforcement ratio. All specimens were modeling in one-third scale size. In this experimental program structural performance of reinforced concrete shear wall were focus at connection types. Based on the test results, the following conclusions are made. In the boundary column member of reinforced concrete shear wall, increasing the ratio of hoop bar in two or three times, in the fully babel type, the shear and horizontal strength of specimens were increased 1.1-1.2 times than that of fully rigid frame. And infilled shear wall specimen were increased 1.17-1.27 times than that. Fully rigid babel type shear wall specimens were increased 5.7~8.0 times, and infilled shear wall specimens were increased about 4.0~5.6 times than that of infilled shear wall specimens.

  • PDF

대형삼축압축시험 및 대형직접전단시험에 의한 사석재료의 전단강도 평가 (Comparison of Shear Strengths of Crushed Rock Determined by Large Triaxial Test and Direct Shear Test)

  • 신동훈;안태봉;이경필;이한출
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.259-264
    • /
    • 2002
  • In this study the shear strengths of a poorly grad ed rock material(d/sub max/≤50.8mm, C/sub u/=1.86) were determined by large direct shear test and large triaxial test. The obtained stress-strain curves by the above large shear tests for the rock materials are similar to the loose sand's or normally consolidated clay's curve, in which the peak strength does not appear obviously. And for the uniformly graded rock material the shear strength by large direct shear test may be overestimated around 1.54∼1.70 times that of large triaxial test.

  • PDF

자연 퇴적 점성토의 비배수 전단강도에 미치는 전단 속도의 영향 (Shear Rate Effect on Undrained Shear Behavior of Holocene Clay)

  • 정민수;채종길;시부야 사토루
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1181-1192
    • /
    • 2008
  • A laboratory investigation was carried out into effects of strain rate on undrained shear behavior of Holocene clay underneath Kobe Airport with an objective to evaluate the factor of safety of the retaining structure built on it. It was examined in a series of triaxial compression and extension tests performed using different rate of axial straining. A comparative compression test in which the strain rate was changed in steps was also carried out. Similar tests were performed in constant-volume direct shear box (DSB) test. And, the deformation characteristics of the clay were also examined in order to evaluate the variation of stiffness during undrained shearing. It was found that the undrained strength increased with not only the shear rate but also the consolidation period. ISOTACH properties seemed a key to govern the undrained shear behavior.

  • PDF

Stud connection in composite structures: development with concrete age

  • Chengqian Wen;Guotao Yang
    • Steel and Composite Structures
    • /
    • 제47권6호
    • /
    • pp.729-741
    • /
    • 2023
  • As the most popular shear connection in composite structures, mature concrete has been widely investigated by considering mechanical properties of stud connectors (SCs) embedded. To further enhance the fabrication efficiency of composite structures and solve the contradiction between construction progress and structural performance, it is required to analyze the shear performance of stud connections of composite structures with different concrete ages. 18 typical vertical push-out tests were carried out on stud shear connectors at concrete ages of 7 days, 14 days, and 28 days. Also, the effects of concrete age, stud spacing and stud diameter on the shear capacity, connection stiffness and failure mode of the connectors were studied. A new relationship expression of load-slip for SCs with various concrete ages was proposed. The existing design code for the SCs shear strength was evaluated according to the experimental data, and a more practical prediction equation for the shear capacity of SCs with different concrete ages was established. A great agreement was observed between the experimental and theoretical results, which can provide a reference for engineering practices.

연속체 암반비탈면의 강도정수 산정 연구 (A Study on Estimating Shear Strength of Continuum Rock Slope)

  • 김형민;이수곤;이벽규;우재경;허익;이준기
    • 한국지반공학회논문집
    • /
    • 제35권5호
    • /
    • pp.5-19
    • /
    • 2019
  • 암반으로 구성되어 있는 급경사($65^{\circ}{\sim}85^{\circ}$)비탈면이 장기간 안정한 상태로 유지되고 있는 자연현상을 고려할 때, 설계 및 초기 시공 단계에서 위와 유사한 지반 상태로 이루어진 깎기 암반비탈면에 대해 1:0.5(발파암 경사 기준)보다 급한 경사를 적용할 수 있을 것이다. 급경사로 설계 가능한 양호한 연속체 암반비탈면의 안정성을 검토하는 과정에서, 설계실무 측면에서 범용적인 암반강도정수 산정방법이 필요하게 되었다. Hoek 등(2002)이 수정 보완하여 발표한 Hoek-Brown 파괴기준과 GSI분류는 불연속구조의 영향을 충분히 고려한 암반특성화 시스템으로 평가되었으며, 응력변화에 따라 등가 Mohr-Coulomb 강도정수(등면적법)를 산출하는 방법을 제안하였다. 비탈면에서는 등가 M-C 강도정수가 최대구속응력(${{\sigma}^{\prime}}_{3max}$ 또는 수직응력)변화에 따라 민감하게 변화하므로 실무적으로 활용하기에 어려운 점이 있다. 이 연구에서는 양호한 연속체 암반비탈면에 대해 최대구속응력 범위이내에서 범용적으로 적용할 수 있는 강도정수산정방법(등각분할법)을 H-B 파괴기준을 응용하여 제안한다. 등각분할법 강도정수(A)의 타당성 및 적용성을 평가하기 위해, 연구대상 암반비탈면을 기존 실시설계 현장 인근에 있는 급경사 비탈면에서 암석종류별(화성암, 변성암, 퇴적암)로 선정하고, Hoek이 제시한 등가 M-C 강도정수(등면적법)들과 비교 분석하였다. 등면적법 및 등각분할법 등가 M-C 강도정수는 기본적인 자료인 기존 실시설계 현장의 실내 암석 삼축압축시험과 연구대상 암반비탈면의 불연속구조의 특성조사(Face Mapping)를 통해 RocLab 프로그램(H-B 파괴기준을 기본으로 전산화된 지반정수 산정 소프트웨어)을 활용하여 산정하였다. 산정된 등면적법 등가 M-C 강도정수는 상호 연동되어 점착력과 내부마찰각이 아주 크거나($45^{\circ}$ 이상) 작게 나타났다. 등각분할법 등가 M-C 강도정수는 등면적법 등가 M-C 강도정수의 중간 정도이며, 내부마찰각은 $30^{\circ}{\sim}42^{\circ}$의 범위를 보인다. 연구대상 암반비탈면의 등각분할법 강도정수(A)와 기존 실시 설계 현장에서 연구대상 암반비탈면과 유사한 암반상태(동일 등급 RMR)에 적용한 강도정수(B)와 비교 분석하고, 이 지반정수들로 적용한 비탈면 안정해석(한계평형해석과 유한요소해석) 결과를 통해 제안한 등각분할법의 적용성을 간접적으로 평가하였다. A와 B의 강도정수 차이는 10% 정도이다. 한계평형해석 결과(우기 기준), A적용 안전율(Fs)=14.08~58.22(평균 32.9), B적용 안전율(Fs)=18.39~60.04(평균 32.2)이며, 각 동일한 암석종류에 따라 상호 유사하게 나타났다. 유한요소 해석 결과, A적용 변위=0.13~0.65mm(평균 0.27mm), B적용 변위=0.14~1.07mm(평균 0.37mm)으로 매우 유사하다. H-B 파괴기준을 응용하여 등각분할법으로 산출한 지반 정수를 실무적인 전단강도로 적용할 수 있는 적용성 평가에서 유의미한 결과를 확인할 수 있었다.

전단내력 감소식을 이용한 고강도 콘크리트 보의 파괴형식 판정 연구 (Decision of Ultimate Failure Mode of High-Strength Concrete Beams Using Degrading Shear Strength Model)

  • 장일영;송재호;박훈규;황규철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.207-212
    • /
    • 2001
  • The aim of this study is to present a practical and simple method for decision of ultimate failure mode of high-strength concrete beam members, based on interaction between shear strength and displacement ductility. Four tests were conducted on full-scale beam specimens having concrete compressive strength of 410kgf/$cm^{2}$. Prediction of failure mode from presented method and comparison with test results are also presented

  • PDF

인공신경망을 이용한 전단보강근이 없는 철근콘크리트 보의 전단강도에 대한 예측 (Prediction of Shear Strength Using Artificial Neural Networks for Reinforced Concrete Members without Shear Reinforcement)

  • 정성문;한상을;김강수
    • 한국전산구조공학회논문집
    • /
    • 제18권2호
    • /
    • pp.201-211
    • /
    • 2005
  • 철근콘크리트 부재의 전단거동에 대한 오랜 연구에 의하여 이에 대한 다양한 이론모델들과 제안식들이 존재한다. 그러나 전판거동의 메커니즘이 복잡하고 영향을 미치는 요소들이 많아서 이론모델들은 대부분 매우 복잡한 경향이 있고, 실험에 의한 제안식들은 제한된 범위내의 실험변수에 대해서만 유효한 경우가 많다. 이러한 문제점을 해결할 수 있는 대안의 하나로써 인공신경망이 여러 연구자들에 의하여 제안되어 왔으며, 본 논문에서는 인공신경망을 이용하여 전단보강근이 없는 철근콘크리트 보의 전단강토를 예측하였다 특히, 기존의 전단실험결과를 광범위하게 모아 구축한 데이타베이스를 활용함으로써 넓은 범위의 구조변수들을 포함한 다양한 부재들을 인공신경망의 훈련자료로 이용하였고, 인공신경망에 의한 전단강토 예측 결과를 ACI의 규준식, Zsutty, Okamura의 제안식들과도 비교 분석하였다. ACI의 규준식은 전단보강근이 없는 철근콘크리트 부재에 대해서 매우 부정확한 전단강도를 제공하였으며, Zsutty의 제안식은 ACI의 규준식에 비해 향상된 예측 결과를 보였으나 부재의 크기효과를 반영하지 못하였다. Okamura의 제안식은 주요 변수들의 영향을 비교적 잘 반영하여 상당히 정확하면서도 안정적인 전단강토를 제공하였다 이에 비해 인공신경망은 실험 결과에 가장 근접한 부재의 전단강도를 제공함으로써, 다양한 변수들의 영향을 매우 정확하게 반영할 수 있는 것으로 나타나서 인공신경망이 전단강도와 같이 메커니즘이 복잡하고 영향을 끼치는 변수들이 많은 다른 구조적 거동이나 강도를 예측하는데 매우 적절한 수단을 제공할 수 있음을 보여주었다.

인위적 입도조정에 따른 지반의 강도특성 변화 (Variation of strength of soil matrix with artificially manipulating particle distribution of granular soil)

  • 문준호;신진화;김갑부;문선미;김영욱
    • 한국산학기술학회논문지
    • /
    • 제19권1호
    • /
    • pp.56-62
    • /
    • 2018
  • 일반적으로 지반의 강도가 강한 지반은 입도분포가 양호하다고 예상할 수 있다. 그러나 Gap입도로 이루어진 지반으로 입도분포가 불량하더라도 지반의 강도가 강한 경우가 있다. 본 연구에서는 이와 같은 사실에 근거하여 인위적으로 조성한 Gap 입도시료와 입도분포가 균일한 시료, 양호한 시료를 직접전단시험을 통하여 지반의 강도정수를 구하고 이를 비교 분석하였다. 또한 13mm 골재와 19mm 골재를 이용한 평판재하시험으로 확대 적용하여 현장 적용성과 입도에 따른 강도 변화의 재현성을 확인하였다. 실험 결과 입자크기비와 내부마찰각이 상관관계가 있음을 확인 할 수 있었고, 특정한 입자 크기비의 범위에서 전단저항각이 상당히 커지는 것을 알 수 있었다. 또한 평판재하시험으로 극한지지력을 산정한 결과 입도조정법이 강도증가율에 크게 영향을 미치는 것을 알 수 있다. 따라서 위의 직접전단 시험을 통한 시험적 검증과 평판재하시험을 통한 재현성 확인을 통해 입도분포가 좋지 않음에도 간단한 입도 조정만으로 지반의 강도 증진을 유도할 수 있었다.

산업부산물을 활용한 고강도 경량콘크리트 보의 전단강도에 대한실험 연구 (Experimental Studies on Shear Strength of High-Strength Lightweight Concrete Beam using the Industrial by-products)

  • 이승조;박정민;김화중
    • 콘크리트학회논문집
    • /
    • 제18권5호
    • /
    • pp.621-630
    • /
    • 2006
  • 산업부산물을 활용한 고강도 경량 콘크리트 보의 역학적 거동 구명과 함께 경량 콘크리트 보의 이론식을 바탕으로 합리적인 전단강도식을 제안하였다. 보는 경량 골재를 사용한 고강도 경량 콘크리트 보(L) 8개와 일반 골재를 사용한 고강도콘크리트 보(H) 4개의 실험체를 제작하였다. 그리고 전단스팬비(a/b=1.5, 2.5, 3.5, 4.5), 인장철근비(${\rho}$=0.57, 1.0, 1.59, 2.3%), 콘크리트의 압축강도(35.4, 65.3MPa)를 주요 변수로 설정하여 실험하였다. 이로부터 보에 대한 하중-처짐관계 및 변형률 분포, 파괴성상, 최대내력 등에 대하여 측정하였다. 또한 보의 전단강도식의 제안을 위하여 사인장 균열 강도와 극한전단강도로 세분화하여 기존 제안식과 규준식에 적용시켜 상호 비교 분석을 하였다. $V_{cr}$에 있어서는 a/b=2.5 이상에서는 ACI 규준식과 Zsutty제안식에서 감소하는 결과였지만, Mathey의 제안식에서는 약간의 상승 경향을 보였다. 또한, ${\rho},\;f_c$의 증가에 따라 $V_{cr,\exp}/V_{cr,cal}$은 과대평가의 경향이 나타났다. 한편, $V_{u, \exp}/V_{u,cal}$에서는 통계적인 방법으로 유도된 Zsutty의 제안식이 실험결과와의 일치성에서 좋은 결과를 보였다. 이 식으로부터 유도 수정된 전단강도에 대한 제안식은 $V_{cr},\;V_u$에서 합리적으로 예측할 수 있음을 알 수 있었다. 따라서 본 연구에서 제안된 전단강도 식은 경량 콘크리트의 전단스팬비, 인장철근비, 콘크리트 압축강도의 변화에 따른 전단내력을 합리적으로 평가하는데 유용하게 활용될 수 있을 것으로 사료된다.

결합재와 베니어세라믹이 금속-세라믹 보철물의 전단결합강도와 계면특성에 미치는 영향 (The Influence of Bonding Strength and Interface Characteristics to Bonding Agent and Veneer Ceramics on Metal-Ceramic Prosthetics)

  • 김민정;최성민;정인성
    • 대한치과기공학회지
    • /
    • 제33권4호
    • /
    • pp.349-357
    • /
    • 2011
  • Purpose: In this study, for the reasons of observing the changes when using bonding agent with Ni-Cr alloy and Co-Cr alloy and using VM13 and Vintage MP ceramic which have the disparity in coefficient of thermal expansion, it is carried out to evaluate the characteristics of the bonding agent through the analysis of the interface between metal and ceramic and the analysis of bond strength by variable. Methods: The surface treatment was performed on the two kinds of alloy(Ni-Cr alloy and Co-Cr alloy) specimens, which were sandblasted and were treated with bonder application. The metal-ceramic interfaces were analyzed with EPMA in order to ionic diffusion, and the shear test was performed. Results: As a result of observation of metal-ceramic interfacial properties, it was observed that Cr atoms were spread from the alloy body to the ceramic floor in the specimen of Group B. It was also seen that Cr, W atoms were spread from the alloy body to the ceramic floor in the specimen of Group S. In consequence of observing Shear bond strength, it was calculated that the specimen of BSV was 27.75(${\pm}11.21$)MPa, BSM was 27.02(${\pm}5.23$)MPa, BCV was 30.20(${\pm}5.99$)MPa, BCM was 27.94(${\pm}10.76$)MPa, SSV was 20.83(${\pm}2.58$)MPa, SSM was 23.98(${\pm}3.94$)MPa, SCV was 32.32(${\pm}4.68$)MPa, and SCM was 34.54(${\pm}10.63$)MPa. Conclusion: In the metal-ceramic interface of Bellabond plus sample group, diffusion of Cr atoms was incurred and diffusion of C Cr atoms and W atoms in the sample group of $Starloy{(R)}\;C$ was observed. Using bonding agent showed the higher bond strength than using the sand blasting treatment. In the Bellabond plus alloys, the specimen group with the use of binding materials showed higher shear bond strength, but didn't show statistically significant differences (p>0.05). In the $Starloy{(R)}\;C$ alloys, the specimen group with the use of binding materials showed higher shear bond strength and statistically significant differences(p<0.05). In terms of VM13 ceramic, it was in the Bellabond plus alloys that the high shear bond strength was showed, but there's no statistically significant differences(p>0.05). In terms of Vintage MP ceramic, it was in the $Starloy{(R)}\;C$ alloys that the high shear bond strength was showed and statistically significant differences(p<0.05). Metal-ceramic to fracture of the shear strength measurements and an analysis of all aspects of military usage fracture of the composite, respectively.