• 제목/요약/키워드: SD500 High-strength bar

검색결과 13건 처리시간 0.017초

Structural Performance of Steel Pipe Splice for SD500 High-strength Reinforcing Bar under Cyclic Loading

  • Kim, Hyong-Kee
    • Architectural research
    • /
    • 제10권1호
    • /
    • pp.13-23
    • /
    • 2008
  • It is the purpose of this study to evaluate the structural performance of steel pipe splice for SD500 high-strength reinforcing bar, through a cyclic loading test. The experimental variables adopted in this study include the development length of rebar, the type of sleeve, and size of reinforcing bar, among others. The results of this study showed that the developed steel pipe splice system for SD500 high-strength reinforcing bar, retained the structural performance required in domestic, ACI and AIJ code. It is considered that the study result presented in this paper can be helpful in developing a reasonable design method for a steel pipe splice system for SD500 high-strength reinforcing bar.

SD500 고강도 철근용 강관 스플라이스 슬리브 철근이음 개발 및 구조성능 평가 (Development of Steel Pipe Splice Sleeve for High Strength Reinforcing Bar(SD500) and Estimation of its Structural Performance under Monotonic Loading)

  • 이상호;김형기
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제11권6호
    • /
    • pp.169-180
    • /
    • 2007
  • 본 연구에서는 SD500 고강도 철근에 적합한 강관 스플라이스 슬리브를 개발한 후에 실물크기의 20개 실험체를 제작하여 가력실험을 실시하였다. 그리고 강도를 비롯한 구조성능을 철근의 정착길이, 슬리브의 타입, 철근의 규격과 같은 실험변수에 따른 영향을 분석하고, 국내기준을 비롯한 주요기준에 따라서 비교, 평가하였다. 실험 결과는 SD500 고강도 철근용으로 개발된 강관 스플라이스 슬리브 철근이음은 주요기준에서 요구하는 구조성능을 가지고 있는 것으로 확인되었고 SD500 고강도 철근용 슬리브 철근이음에 대한 구조설계 기준 확립을 위한 기술적 자료를 제시하였다.

반복하중을 받는 SD500 고강도 철근용 모르타르 충전식 슬리브 철근이음의 구조성능 (Structural Performance of Mortar-filled Sleeve Splice for SD500 High-strength Reinforcing Bar under Cyclic Loading)

  • 김형기
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제12권6호
    • /
    • pp.180-192
    • /
    • 2008
  • 본 연구에서는 보다 자유로운 형상의 슬리브를 만들 수 있는 구상흑연 주철을 이용하여 보다 효과적으로 구조성능을 발휘하면서 SD500 고강도 철근에 적합하게 개발된 모르타르 충전식 슬리브 철근이음을 대상으로 실물크기의 19개 실험체를 제작하여 반복가력실험을 실시하였다. 그리고 강도, 강성, 슬립을 중심으로 한 구조성능에 대하여 본 실험의 주요한 변수에 따르는 영향을 분석하고, 국내기준을 비롯한 주요기준의 요구 성능과 비교하였다. 본 연구결과에서는 SD500 고강도 철근용으로 개발한 모르타르 충전식 슬리브 철근이음은 반복하중이 작용하는 경우에 대하여 국내기준을 비롯한 주요기준에서 요구하는 구조성능을 보유하고 있는 것이 확인되었고, SD500 고강도 철근용 모르타르 충전식 슬리브 철근이음에 대한 구조설계 기준 정립에 필요한 정량적인 기술 데이터를 제시하였다.

초고강도 철근이음의 경제성 평가모델 개발에 관한 연구 (A Study on the Economic Evaluation Model of Splice of Reinforcement Bar(SD500))

  • 김재엽;김대원
    • 한국건축시공학회지
    • /
    • 제8권1호
    • /
    • pp.71-76
    • /
    • 2008
  • Recently, the high-rise apartment housings have become a prototype of the urban residential dwelling in Korea and the numbers of one have steadily been increasing. According to this trend, the strength of the construction materials is also fortified to assure the stability and durability of the buildings. Specially, Re-bar of SD500 type is largely used at the construction sites of high-rise building. This study analyzes the current usage of SD500 high-strength re-bar at domestic construction sites. Through the result of this analysis, we develop Economic Evaluation Model that measure economic efficiency of lap splice and coupler splice, which are most commonly used in connection SD500. The evaluation method was applied to construction sites in Seoul in December 2006, and the result revealed that coupler splice is relatively superior in terms of cost efficiency when the re-bar diameter is longer and the concrete strength is lower.

SD500철근 커플러 이음의 편익/비용분석에 관한 연구 (A Study on Benefit/Cost Analysis of Re-Bar Connection Methods for Hyper Strength(SD500) Reinforcement)

  • 김재엽;권여울;김준영
    • 한국건축시공학회지
    • /
    • 제8권2호
    • /
    • pp.81-87
    • /
    • 2008
  • High-rise building is taking a place as one of building types from apartment housings to commercial buildings. With taking in account of stability and durability, strength of used materials is increasing gradually in these high-rise buildings. According to this, frequency in use of SD500 re-bar is increasing gradually in high-rise buildings. However the study of SD500 re-bar is insufficient because SD500 re-bar started to be used for domestic buildings lately. Specially because there is no guide or study to refer to, people get into difficulties when to decide the method of re-bar connection in construction using SD500 re-bar. Accordingly in this study, it suggests the method of estimating the economical efficiency on SD500 re-bar connection, and conducts benefit/ cost analysis on lapped splice and coupler splice by applying AHP theory, and then presents its result. After to analyze re-bar diameter of D25, 29, and 32, finally we attained the result that the coupler splice is advantageous in all parts of benefit/ cost more than the lapped splice.

SD500 고강도 철근용 커플러이음의 경제성 평가에 관한 연구 (A Study on Economic Evaluation Method of Coupler Splice for High Strength(SD500) Reinforcement)

  • 김재엽;김광희
    • 한국건설관리학회논문집
    • /
    • 제8권2호
    • /
    • pp.136-145
    • /
    • 2007
  • 우리나라의 초고층 건축물은 초고층아파트가 대도시 주거건축의 대표적인 유형으로 등장하면서 점차 증가하고 있다. 최근 건축되고 있는 이러한 초고층 건축물에서는 건물의 안정성과 내구성 등을 감안하여 사용재료의 강도도 점차 증가하고 있다. 이에 따라 철근의 경우 SD500철근을 사용하는 공사현장을 쉽게 볼 수 있게 되었다. 이에 본 연구에서는 국내의 건축공사에서 사용되는 SD500철근의 사용 실태를 분석하였다. 또한 SD500철근의 이음방법으로 많이 사용되고 있는 겹침이음과 커플러이음에 대한 경제성 평가방법을 제안하고, 이를 2006년 12월 서울을 기준으로 평가하였다. 경제성 평가 결과, 커플러 이음은 철근직경이 클수록 콘크리트의 강도가 낮을수록 겹침이음에 비해 공사비용 측면에서 상대적으로 유리한 것으로 분석되었다.

반복하중이 작용하는 고강도 모르타르 충전식 슬리브 철근이음에 대한 강성 평가 (Evaluation on Stiffness of High-strength Mortar-filled Sleeve Bar Splice Under Cyclic Loading)

  • 김형기;정구용
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권1호
    • /
    • pp.85-93
    • /
    • 2013
  • 본 논문에서는 반복하중이 작용하는 고강도 모르타르 충전식 슬리브 철근이음의 강성에 대한 합리적인 검토를 하기 위하여 100여개 고강도 모르타르 충전식 슬리브 철근이음의 실험데이터를 이용하여 슬리브 철근이음이 보유하고 있는 구조인자가 반복 하중이 작용하는 슬리브 철근이음의 강성에 미치는 효과를 파악하였고, AIJ 규준에 정해져 있는 강성 등급을 충족시키는 최소한 의 조건에 대하여 평가한 결과, SD350과 SD400 철근을 매입한 모르타르 충전식 주물 슬리브 철근이음에서 $f_{g^*}$(L/d)가 470MPa 이상이 된다면 AIJ 규준의 SA급 강성, $f_{g^*}$(L/d)가 340MPa 이상이 된다면 AIJ 규준의 A급 강성을 최종파괴형식과 슬리브 형상에 상관없이 확보할 수 있는 것으로 나타났다. 또한 SD500 철근을 매입한 모르타르 충전식 슬리브 철근이음에서 주물슬리브와 강관 슬리브를 사용한 경우는 $f_{g^*}$(L/d)가 400MPa 이상이 된다면 AIJ 규준의 A급 강성을 확보할 수 있는 것으로 나타났다.

SD700 확대머리 철근의 겹침이음 상세를 적용한 단차가 있는 RC 보의 구조성능 평가 (Evaluation of Structural Performance of RC Beam with Different Depths to Lap Splice Detail of SD700 Headed Bar)

  • 이지형;김승훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권6호
    • /
    • pp.262-269
    • /
    • 2021
  • 본 논문은 SD700 확대머리철근의 겹침이음을 이용한 단차가 있는 보의 접합상세를 개발하기 위하여 실시한 구조성능평가 실험결과를 나타낸다. 실험변수는 주철근의 겹침이음길이, 철근 항복강도, 단부정착상세 등이다. 모든 실험체에 대하여 춤이 작은 보(B2)의 하부 주철근은 확대머리철근을 적용하였으며, 춤이 큰 보(B1)의 하부 주철근은 일자형 확대머리철근, 90° 갈고리형 확대머리철근 등 두 가지 상세로 이음방법을 적용하였다. 실험결과, SD500과 SD600을 적용한 실험체들은 겹침이음부에서 모두 휨파괴되었으며, 이로 인하여 최대내력은 유사하게 나타났다. SD500을 적용한 실험체들에 대하여, B1의 주철근을 90°갈고리형 확대머리철근으로 적용한 상세가 확대머리철근에 비하여 겹침이음부의 수평균열을 억제하였다. SD700의 확대머리철근을 사용한 실험체는 취성적인 정착파괴가 나타났으며, 겹침이음길이의 증가에 따라 최대내력이 증가하였다. SD700의 확대머리철근을 사용한 실험체들은 실험체정착길이/이론정착길이에 대한 실험내력/이론내력이 ACI 318-19 식은 1.30~1.48로 나타났으며, KDS-2021 식은 1.14~1.30로 평가되었다. 이를 볼 때, ACI 318-19 산정식이 보다 보수적으로 정착길이를 평가함으로써 더 큰 안전율을 가지고 있었다.

고강도 철근 사용에 따른 순수 철근량에 대한 정착 및 이음 철근량 비교 (Comparison of Pure Reinforcement Quantity to Development & Splice Reinforcement Quantity using High-strength Reinforcing Bars)

  • 조승호;나승욱;노영숙
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권1호
    • /
    • pp.72-80
    • /
    • 2018
  • 초고층 및 장경간 등 대형 구조물에 대한 시공시 부재의 품질이 저하될 정도로 과다한 철근이 배근되고 있다는 문제점이 제기되고 있으며, 최근 건축되고 있는 초고층 건축물에서는 건물의 안정성과 내구성 등을 감안하여 사용 재료의 강도도 점차 증가하고 있다. 초고층 및 장경간 구조물의 시공에서 고강도 철근을 사용할 경우 기존의 일반 강도 철근에 비해 배근량 감소로 인하여 부재에서 배근 간격에도 여유를 줄 수 있어 시공성 향상, 공기단축, 접합부 상세가 간소화 되는 장점이 있다. 이 연구에서는 SD500, SD600 철근을 국내에서 설계되었거나 시공되어진 라멘 구조 형식의 지하주차장 건축물에 적용하여 각 부재별로 철근의 강도에 따른 순수 철근량에 대한 정착 및 이음 철근량 증감을 비교 분석한 결과 다음과 같은 결론을 얻었다. 계산된 철근의 정착 및 이음 물량은 사용철근의 강도가 증가함에 따른 정착 및 이음길이의 증가량과 순수 물량의 감소비율, 사용철근의 직경이 줄였을 때의 단면적 감소 등의 요인들에 의해 정착 및 이음 물량이 결정되었으며, 전체적으로 순수 물량에 대한 정착 및 이음 물량의 비율이 SD400대비 SD500의 경우는 증가하였지만 SD500대비 SD600의 경우는 감소하였다. 이는 보의 정착 및 이음 물량이 전체 정착 및 이음 물량에 미치는 영향이 크기 때문으로 판단된다. 한편 순수 물량에 대한 정착 및 이음 물량의 비율에서 SD400과 SD500의 차이와 SD400과 SD600의 차이가 미미하여 철근의 정착 및 이음 물량이 강도 증가에 따른 전체 철근 물량의 증감에는 큰 영향을 주지 않는 것으로 파악되었다.