Evaluation on Stiffness of High-strength Mortar-filled Sleeve Bar Splice Under Cyclic Loading  

Kim, Hyong Kee (강원대학교 건축공학과)
Chung, Goo Yong (강원대학교 건축공학과)
Publication Information
Journal of the Korea institute for structural maintenance and inspection / v.17, no.1, 2013 , pp. 85-93 More about this Journal
Abstract
In order to make a more reasonable evaluation on the stiffness of the high-strength mortar-filled sleeve bar splices under cyclic loading, we investigated and analyzed the existing experiment data of 106 full-sized reinforcing bar splices with test variables such as compressive strength of mortar, development length of reinforcement and sleeve type, etc. The following were found: 1) If mortar and the reinforcement development length with $f_{g^*}$(L/d) of more than 340 is used, the cast iron sleeve bar splices for SD350 and SD400 will have the stiffness of higher than A class of the AIJ code. 2) If mortar and the reinforcement development length with $f_{g^*}$(L/d) of more than 400 is used, the cast iron sleeve splices and pipe sleeve splices for SD500 will have the stiffness of higher than A class of the AIJ code.
Keywords
High-strength mortar-filled sleeve bar splice; Stiffness; Cyclic loading; Evaluation;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Architectural Institute of Japan, "Recommendation for Detailing and Placing of Concrete Reinforcement", 2010, pp.356-365. (in Japanese)
2 Ase, M., Abukawa, M. and Okata, T., "Study for practical application of grout filled connectors for high strength reinforcing bars(No. 1 Performance of the grout filled connector with SD490 reinforcing bars)", Summaries of Technical Papers of Annual Meeting Architectural Institute of Japan, C-2, Structures IV, 1996, pp.743-744. (in Japanese)
3 Japan Splice Sleeve Company, "Performance test result for bar connection using several NMB splice sleeve", Report for Performance Test According to Size of Reinforcing Bar, 1993, pp.1-5. (in Japanese)
4 Japan Splice Sleeve Company, "Report of experimental result for workability of NMB splice sleeve bar connection for RPC construction method", Report for Performance Evaluation of NMB Splice Sleeve 13U-X(D41) Bar Connection / Report for Performance Evaluation of NMB Splice Sleeve 13U-X(D41) and 11U-X(D35) Bar Connection, 1992/1993. (in Japanese)
5 Kim, H., "Comparative evaluation on strength of several grout-filled splice sleeve", Journal of the Korea Concrete Institute, vol. 16, No. 5, 2004, pp.635-643. (in Korean)   DOI   ScienceOn
6 Kim, H., "Evaluation on stiffness of mechanical sleeve bar splice filling high-strength mortar under monotonic loading", Journal of the Korea Institute for Structural Maintenance Inspection, vol. 16, No. 4, 2012, pp.79-88. (in Korean)   DOI   ScienceOn
7 Kim, H., "Experimental study on tensile strength and ductility of high strength grout-filled splice sleeve", Journal of Architectural Institute of Korea, vol. 18, No. 12, 2002, pp.35-42. (in Korean)   과학기술학회마을
8 Kim, H., "Mechanical performance of grout-filled splice sleeve system under cyclic loading", Journal of Architectural Institute of Korea, vol. 14, No. 9, 1998, pp.73-81. (in Korean)   과학기술학회마을
9 Kim, H., "Structural performance of mortar-filled sleeve splice for SD500 high- strength reinforcing bar under cyclic loading", Journal of the Korea Institute for Structural Maintenance Inspection, vol. 12, No. 6, 2008, pp.169-180.   과학기술학회마을
10 Kim, H., "Structural performance of steel pipe splice for SD500 high-strength reinforcing bar under cyclic loading", Architectural Research, vol. 10 No. 1, 2008, pp.13-23. (in Korean)   과학기술학회마을
11 Samsung Engineering & Construction. and Daedong MS, "Report for development and experimental study of grout-filled splice sleeve system", Report for Technical Development and Research, 1998. (in Korean)