• Title/Summary/Keyword: SCREEN TEST

Search Result 627, Processing Time 0.025 seconds

Correlation Between Functional Movement Screen Scores, Lower Limb Strength, Y-Balance Test, Grip Strength, and Vertical Jump and Incidence of Injury Due to Musculoskeletal Injury Among Abu Dhabi Police Recruits

  • Hamad Alkaabi;Everett Lohman;Mansoor Alameri;Noha Daher;Aleksandar Cvorovic;Hatem Jaber
    • Physical Therapy Rehabilitation Science
    • /
    • v.12 no.3
    • /
    • pp.222-228
    • /
    • 2023
  • Objective: Training-related injuries and attrition put an additional burden on police and military institutions. Preventing and minimizing musculoskeletal injuries is the primary concern of the Abu Dhabi Police. Therefore, this study aimed to evaluate the correlation between functional movement screen, lower-limb strength, Y-balance test, grip strength and vertical jump and the incidence of musculoskeletal injuries among Abu Dhabi police recruits. Design: Observational analytical study. Methods: An observational study was conducted on 400 male police recruits of Abu Dhabi Police Academy. Physical performance was assessed before the 16-weeks basic police training. Spearman's correlation evaluated the correlation between the performance parameters and the outcome measures and logistic regression predicted the risk factors associated with musculoskeletal injuries. Results: 149 (34.4%) participants reported at least one injury during the basic police training. Comparison between injured and non-injured participants showed significant difference in mean right Y-balance, back-leg-chest dynamometer, and vertical jump (p=0.02, p=0.02, and p=0.04, respectively). Spearman's correlation showed a significant negative correlation between risk of injury and back-leg-chest dynamometer and right Y balance (ρ= -0.11, p=0.03). Logistic regression showed that back-leg-chest dynamometer and right Y balance were significant predictors of injury (p =.036 and p=0.037; Odds ratio=0.96; 95% CI (0.92, 0.99) and Odds ratio=0.99; 95% CI (0.98,0.99). Conclusions: Our findings suggest functional movement screen and grip strength may not independently predict injury rates, balance and lower-limb strength needs to be considered in injury prevention strategies to reduce musculoskeletal injuries.

Implementation of N-screen based solar power monitoring system (태양광 발전 모니터링 시스템의 N 스크린 기반 구현)

  • Lee, Kyong-Ho;Park, Hee-Wan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.10
    • /
    • pp.151-158
    • /
    • 2014
  • In this paper, we have designed and implemented the 'N-screen based solar power monitoring system' using N-screen technology by improving the existing monitoring system that can only be accessed or controlled by PC. The HW of the system is consists of solar power modules, inverter, and relay server. And SW is implemented in consideration of the following three points. First, we applied the N-screen technology in order to support various devices. Second, we applied 1:N communication technology that multiple devices can be connected simultaneously to the relay server. Third, we also considered the security problems between server and devices. The final system has been evaluated through the operational test and received good reviews from the technical and economic point. In the future, we are expecting that this technology will replace the existing monitoring systems in various fields, like smart home, smart building, smart city, smart industry, and smart agriculture, etc.

Effects of the Wire-screen Rib on Heat Transfer and Friction Factors (와이어 스크린 리브이 열전달과 마찰계수에 미치는 효과)

  • Oh, Se-Kyung;Ahn, Soo-Whan;Lee, Dae-Hee
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.2
    • /
    • pp.196-203
    • /
    • 2011
  • Experiments to determine heat transfer coefficients and friction factors are conducted on a stationary transverse parallel wire-screen rib roughened rectangular channel. The test section consists of 198 mm (W) x 40 mm (H) x 712 mm (L). The channel has the aspect ratio of 4.95 and hydraulic diameter of $D_h$=6.66 cm. Four wire screen ribs and a solid rib are used. 0.1 mm-thick-stainless steel foil heaters and thermocouples (T type) are used to measure the heat transfer coefficients. Reynolds numbers studied range from 20,000 to 60,000. The wire-screen rib height (e) to hydraulic diameter ($D_h$) ratio ($e/D_h$) is 0.075; spacing (p) to height ratio (p/e) is 10. Results indicate that the solid rib produces the greatest Nusselt number and friction factor.

Security Improvement Methods for Computer-based Test Systems (컴퓨터 기반 평가 시스템의 보안성 강화 방안)

  • Kim, Sang Hyun;Cho, Sang-Young
    • Convergence Security Journal
    • /
    • v.18 no.2
    • /
    • pp.33-40
    • /
    • 2018
  • ICT technology has been applied to various educational fields, but applying to educational test field is limited. Computer-based test (CBT) can overcome temporal and spatial constraints of conventional paper-based test, but is vulnerable to fraud by test parties. In this paper, we propose real-time monitoring and process management methods to enhance the security of CBT. In the proposed methods, the test screens of students are periodically captured and transferred to the professor screen to enable real-time monitoring, and the possible processes used for cheating can be blocked before testing. In order to monitor the screen of many students in real time, effective compression of the captured original image is important. We applied three-step compression methods: initial image compression, resolution reduction, and re-compression. Through this, the original image of about 6MB was converted into the storage image of about 3.8KB. We use the process extraction and management functions of Windows API to block the processes that may be used for cheating. The CBT system of this paper with the new security enhancement methods shows the superiority through comparison of the security related functions with the existing CBT systems.

  • PDF

Improvement of the Cognitive Perceptual Assessment for Driving (CPAD) based on Usability Test

  • Bae, Jae-Hyuk;Lee, Jung-Ah;Choi, Hyun;Lee, Jae-Jin
    • Journal of the Ergonomics Society of Korea
    • /
    • v.34 no.4
    • /
    • pp.335-351
    • /
    • 2015
  • Objective: The aim of this study was to perform a usability test for CPAD (Cognitive Perceptual Assessment for Driving) and improve it based on the test results. Background: The cognitive perceptual assessment for driving is a computer-based assessment tool to assess the driving capacity of people with brain-damages. It may be a good tool for evaluating the brain-damaged drivers' safe driving capabilities and screening cognitive and perceptual deficits related to driving. We performed a usability test to improve the CPAD based on the result. Method: Both the software consisting of 8 sub-tests (depth perception, sustained attention, divided attention, stroop test, field dependency, digit span, trail making A, trail making B) and the hardware including the input and output devices ( joystick, mouse, keyboard, touch screen) were evaluated through user interviews. Also we identified the problems and issues in using them by observing the participants performing the CPAD tasks. Results: Based on the results, the task instructions were visually and auditorily improved and more practice examples were added to help the users understand the instructions better and increase the input accuracy, a response time window was added and the joystick and touch screen were simplified, which made it easier for the user to perform the CAPD tasks. Conclusion: User discomforts were minimized by improving the task environment, unless it had affected the evaluation criteria. Application: We plan to distribute the improved version of the CPAD to the regional rehabilitation hospitals, and the driving support centers for people with disabilities throughout the country, so it could be used as an evaluation tool for disabled drivers' cognitive and perceptual functions.

Electrical Behavior of the Circuit Screen-printed on Polyimide Substrate with Infrared Radiation Sintering Energy Source (열소결로 제작된 유연기판 인쇄회로의 전기적 거동)

  • Kim, Sang-Woo;Gam, Dong-Gun;Jung, Seung-Boo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.3
    • /
    • pp.71-76
    • /
    • 2017
  • The electrical behavior and flexibility of the screen printed Ag circuits were investigated with infrared radiation sintering times and sintering temperatures. Electrical resistivity and radio frequency characteristics were evaluated by using the 4 point probe measurement and the network analyzer by using cascade's probe system, respectively. Electrical resistivity and radio frequency characteristics means that the direct current resistance and signal transmission properties of the printed Ag circuit. Flexibility of the screen printed Ag circuit was evaluated by measuring of electrical behavior during IPC sliding test. Failure mode of the Ag printed circuits was observed by using field emission scanning electron microscope and optical microscope. Electrical resistivity of the Ag circuits screen printed on Pl substrate was rapidly decreased with increasing sintering temperature and durations. The lowest electrical resistivity of Ag printed circuit was up to $3.8{\mu}{\Omega}{\cdot}cm$ at $250^{\circ}C$ for 45 min. The crack length arisen within the printed Ag circuit after $10{\times}10^4$ sliding numbers was 10 times longer than that of after $2.5{\times}10^4$ sliding numbers. Measured insertion loss and calculated insertion loss were in good agreements each other. Insertion loss of the printed Ag circuit was increased with increasing the number of sliding cycle.

Assessing Heavy Metals for Estrogenicity Using a Combination of In vitro and In vivo Assays (In vitro 및 In vivo Assay를 통한 중금속의 에스트로겐성 평가)

  • Park, Chul;Kim, So-Jung;Shin, Wan-Chul;Kim, Hae-Gyoung;Choe, Suck-Young
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.9
    • /
    • pp.1486-1491
    • /
    • 2004
  • The estrogenicities of six heavy metal compounds, which contaminate frequently in foods, were assayed using a combination of in vitro and in vivo assays. The assays were 1) estrogen receptor dependent transcriptional expression assay, 2) E-screen assay and, 3) the uterotropic assay in mice. The chemicals studied were 17$\beta$ -estradiol, diethylstilbestrol (DES), arsenic oxide, bis(tri-n-butyltin), cadmium chloride, chromium chloride, lead acetate, and mercuric chloride. Using the estrogen receptor dependent transcriptional expression assay, the following estrogenicity ranking was measured: bis(tri-n-butyltin) > cadmium chloride > chromium chloride >> mercuric chloride >lead acetate = arsenic oxide. Using E-screen test, the following estrogenicity ranking was measured: bis(tri-n-butyltin) > cadmium chloride > chromium chloride >> mercuric chloride > lead acetate = arsenic oxide. Results from the uterotropic assay showed that bis(tri-n-butyltin), cadmium chloride, chromium chloride caused an increase in uterine wet weight, while lead acetate, mercuric chloride, and arsenic oxide failed to do so. Bis(tri-n-butyltin), cadmium chloride and chromium chloride showed the highest estrogenicity in three assay systems. Recent studies suggesting that bis(tri-n-butyltin), cadmium chloride have estrogenicities are compatible with the present finding. Furthermore, our study is suggesting that chromium chloride may be estrogenic. The results demonstrate that this three level-assay combination (transcriptional activation, cell proliferation, and an in vivo effect in an estrogen-responsive tissue) could serve as a useful method to assess the estrogenicity of heavy metals.

The Influence of Altering Mobile Phone Interface on the Generation of Mental Model (모바일 폰의 인터페이스 변경이 멘탈모델 형성에 미치는 영향)

  • Park, Ye-Jin;Kim, Bon-Han
    • Science of Emotion and Sensibility
    • /
    • v.11 no.4
    • /
    • pp.575-588
    • /
    • 2008
  • This study is to inquire respective patterns of mental models caused by wrongful usages which can be experienced when a user who is used to a keypad-based mobile phone starts using a touch screen mobile phone and to find out the features of the user's logical process of correcting such wrongful usages to a new mental model. In addition, design improvement to be considered for easy generation of the mental model regarding touch screen mobile phones was reviewed in this study. We set up test subjects for the most frequently used seven high priority functions among touch screen phone functions and carried out the subject assessment together with interview surveys after the video observation experiment. Our test results show that test subjects who were used to keypad-based mobile phones tend to use operation knowledge related to the computer operational system(Window) or the web browse, navigation including Tap or Double Tap in order to correct the mental model when a wrongful usage is made. In addition, the result of comparison and analysis of the subject assessment and the video observation experiment data shows that wrongful usages of touch screen mobile phones mostly occurred in the field of 'information feedback' and 'navigation' among mobile phone components.

  • PDF

Effects of Film Stack Structure and Peeling Rate on the Peel Strength of Screen-printed Ag/Polyimide (박막 적층 구조 및 필링 속도가 스크린 프린팅 Ag/Polyimide 사이의 필 강도에 미치는 영향)

  • Lee, Hyeonchul;Bae, Byeong-Hyun;Son, Kirak;Kim, Gahui;Park, Young-Bae
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.29 no.2
    • /
    • pp.59-64
    • /
    • 2022
  • Effects of film stack structure and peeling rate on the peel strength of screen-printed (SP) Ag/polyimide (PI) systems were investigated by a 90° peel test. When PI film was peeled at PI/SP-Ag and PI/SP-Ag/electroplated (EP) Cu structures, the peel strength was nearly constant regardless of the peeling rate. When EP Cu was peeled at EP Cu/SP-Ag/PI structure, the peel strength continuously increased as peeling rate increased. Considering uniaxial tensile test results of EP Cu/SP-Ag film with respect to loading rate, the increase of 90° plastic bending energy and peel strength was attributed to increased flow stress and toughness. On the other hand, viscoelastic PI film showed little variation of flow stress and toughness with respect to loading rate, which was assumed to result in nearly constant 90° plastic bending energy and peel strength.

Reliability and Validity of the Korean Version of the Functional Movement Screen (한국판 기능적 동작 검사의 신뢰도와 타당도)

  • An, Seung-Heon;Lee, Je-Hoon
    • The Journal of Korean Physical Therapy
    • /
    • v.22 no.5
    • /
    • pp.83-93
    • /
    • 2010
  • Purpose: The purpose of this study was to determine the reliability and validity of the Functional Movement Screen (FMS) for assessing Korean athletes. Methods: A total of 48 patients (37 males and 11 females) participated in this study. Data were acquired after translation of the FMS from English to Korean and cross-cultural adaptation of the this questionnaire. To determine inter-rater reliability, the relationship between the FMS scores obtained by two raters was evaluated using the Kappa coefficient, which was in total agreement with the Intra-Correlation Coefficient (ICC3,1). Concurrent validity was examined by correlating the FMS scores with the Oswestry disability index (ODI) scores and Visual analogue scale (VAS) scores. Results: The raters demonstrated excellent agreement on 7 (above 90%) of the 17 test (72.9 to 97.9%) components. Substantial agreement was seen in 11 of the 17 tests. Two components of the In-line lunge and rotatory stability tests demonstrated moderate agreement. It showed good inter-rater reliability: the Kappa coefficients ranged from 0.42 to 0.97. ICC3,1=0.42~0.99 and 0.93 (total FMS score). Cronbach's alpha for FMS was 0.80. It was not correlated with ODI or VAS. Conclusion: The Korean version of the FMS is a reliable instrument for measuring movement patterns of Korean athletes and for making decisions related to interventions for performance enhancement.