• Title/Summary/Keyword: SCADA data

Search Result 207, Processing Time 0.029 seconds

Investigation and Complementary Measures Establishment for Flood on Tidal Reclaimed Paddy Fields (간척지 논 침수 원인 조사와 방재 대책 수립)

  • Jeong, Ju-Hong;Yoon, Kwang-Sik;Choi, Soo-Myung;Yoon,, Suk-Gun;Go, Young-Bae;Kim, Young-Taek
    • KCID journal
    • /
    • v.17 no.2
    • /
    • pp.105-114
    • /
    • 2010
  • Tidal land reclamation provided water resources and land for agriculture and contributed stable crop production. However, climate change by global warming disrupts the hydrologic circulatory system of the earth resulting in sea level rise and more frequent flood for reclaimed arable land. Recently, Suyu reclaimed paddy field in Jindo-gun experienced prolonged inundation after heavy rainfall and there is a growing risk of flood damage. Onsite survey and flood analysis using GATE_Pro model of Korea Rural Corporation were conducted to investigate causes of flooding. To perform the analysis, input data such as inflow hydrograph, the lowest elevation of paddy field, neap tide level, management level of Gunnae estuary lake at the time of the flood were collected. Flood analysis confirmed that current drainage facilities are not enough to prevent 20year return period flood. The result of analysis showed flooding more than 24hours. Therefore, flood mitigation alternatives such as sluice gate expansion, installation drainage pumping station, refill paddy land, and catch canal were studied. Replacing drainage culvert of Suyu dike to sluice gate and installing drainage pumping station at the Gunne lake were identified as an effective flood control measures. Furthermore, TM/TC (SCADA) system and expert for gate management are required for the better management of drainage for estuary dam and flood mitigation.

  • PDF

An ICCP Application Method for an Error Decrease of the Power Control Communication System (전력제어 통신 시스템의 에러 감소를 위한 ICCP 적용 방안)

  • 김종빈;정래성
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.40 no.9
    • /
    • pp.349-357
    • /
    • 2003
  • Because of capacity of the electric power equipment grew larger and the electric power system was complicated, it was required a protocol to process data without the errors in order to supply the high quality and stable electric power. However, HDLC and TCP/IP communication protocol using between Seoul EMS and Kwangju RCC (or between RCC and SCC) is decreasing reliability by the delay of speed and the occurrence of errors. In this paper, we applied ICCP(Inter-Control Center Communication Protocol) communication protocol in order to improve them and implemented an electric power communication system for remote control of the electric power equipment. Also, we modified program for error correction and implemented the system using the most suitable BLT. The errors were more decreased in case of ICCP protocol than HDLC protocol and TCP/IP protocol applied to the electric power communication system.

Trend Analysis and Diagnosis for BWTS Remote Monitoring (BWTS 원격 모니터링을 위한 트렌드 분석 및 진단)

  • Choi, Wook-Jin;Kim, Chin-Hoon;Choi, Hwi-Min;Lee, Kwang-Seob;Choi, Woo-Jin;Kim, Joo-Man
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.9 no.3
    • /
    • pp.127-135
    • /
    • 2014
  • On lot of ships, Ballast Water Treatment Systems(BWTS) are in use, or the newly built ship should be mandatory installation by 2017. It is IMO(International Maritime Organization) regulations. Because the vessel is in long distance, It is managed this system only in the vessel and it may occur considerable cost of maintenance when a problem arises from BWTS. We describe in this paper how to monitor treated ballast water to make sure the ballast water and BWTS on a ship is in proper condition, but before the port entrance. In addition, analysing and forecasting trend signal to prevent failure. Also we can expect reduce the cost of BWTS maintenance. We can monitor the sensor data value's change which collected through satellite from BWTS. And we can observate the ballasting and de-ballasting state of the vessel easily.

Power System Design in the Inchon Inta'l Airport (인천국제공항 전력시스템 설계)

  • Oh, Y.D.;Min, S.J.;Lim, J.G.;Moon, J.H.;Lee, T.S.;Lee, K.S.;Son, J.Y.;Kim, J.H.;Moon, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1125-1127
    • /
    • 1998
  • Inchon International Airport(IIA) is constructed for Northeast Asia Gate as is important for IIA to become a 21 century's leader in the world. as is planned for open at December 2000 as a important economic link for unified korea. Power System is designed through investigation of advanced domestic and international example. In addition to power facility operation it is designed for using an information infrastructure of whole airport. IIA Power System Design make instantaneously the Power Distribution Facilities and the SCADA System to construct the airport. and the Airport Power Information System to operate the Power System. It is designed to take efficient and safe Power System including the advanced technology. Power System make the integrated Power Information Database to operate the Main Control Center, analyze the data about the relation of the Power System and Airport operation, and will support the important files in the future.

  • PDF

Real-time optimal pump operation model development (경제적인 용수공급을 위한 실시간 송수펌프의 최적운영 모형 개발)

  • Kim, Kang Min;Choi, Jeong Wook;Kang, Doosun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.185-185
    • /
    • 2016
  • 일반적인 송 배수시스템의 운영은 지대가 높은 곳에 위치한 배수지(tank)에 용수를 저장한 후, 자연유하에 의해 수요절점으로 용수를 공급한다. 이때 배수지에 용수를 송수하기 위한 펌프장 운영에서 많은 전기에너지가 소모된다. 일반적으로 송수펌프의 운영은 다년간의 운영자료를 기반으로 운영자의 판단에 의해 이루어지거나, SCADA(Supervisory Control and Data Acquisition)시스템을 통해 관측되는 배수지 수위를 기준으로 펌프 작동여부를 결정하고 있다. 본 연구에서는 이러한 기존 펌프운영방법을 개선하고 좀 더 효율적인 운영방법을 모색하기 위해 실시간 송수펌프 최적운영 모형을 개발하였다. 최적화 기법으로는 유전자 알고리즘(genetic algorithm)을 사용하였으며, 다양한 제약조건(operational constraints)을 적용하고 급수지역의 24시간 용수사용량을 미리 예측하여 실제 시스템의 운영형태와 근접하게 반영하였다. 또한 최적화 과정에서 상수관망해석 프로그램(EPANET)을 연계하여 수요절점의 수압조건 및 시스템의 운영상황을 모의하였다. 개발된 모형을 국내 P시의 광역상수도 시스템에 실제 적용하였으며, 현장 실시간 운영 데이터를 입수하여 전력사용량, 배수지수위, 이산화탄소 발생량 등을 비교, 분석하였다. 개발 모형을 이용하여 펌프운영을 실시하였을 경우, 기존의 운영방식과 비교하여 경제적/환경적으로 뚜렷한 개선 효과를 확인할 수 있었다.

  • PDF

Estimation method of natural rate of rise of leakage in water distribution system (배급수관망에서의 누수복원량 산정방법)

  • Jin, Saemmul;Kim, Kyoungpil;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.4
    • /
    • pp.299-309
    • /
    • 2019
  • Waterworks facilities inevitably experience some amount of leakage even if there is a lot of investment or state-of-the-art technology that is applied such as DMA(District Metered Area) system construction, leakage detection, repair, pipe rehabilitation, etc. The primary reason is the leakage is naturally restored over time. In the UK, this restoration characteristic is defined as NRR(Natural rate of rise of leakage) and used to decision making for prioritizing active leakage control of DMAs. However, this restoration characteristic is well recognized, but researches on NRR in the water distribution system are insufficient in Korea. In this study, the estimation method of NRR was developed suitable for applicating in Korea considering of SCADA data, water infrastructure, and water usage patterns by modification of the UK's NRR method. The proposed method was applied to 9 DMAs and verified it's applicability by comparing with the other water loss performance indicators. It is expected that the proposed method can be used to support decision making for sustainable NRW(Nor-revenue water) management in the water distribution system.

EPON Based Communication Network Architecture for Offshore Wind Power Farm (EPON을 기반으로 한 해상 풍력 단지 통신망 구조)

  • Jung, Jin-Hyo;Yang, Wonhyuk;Kim, Young-Chon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.2
    • /
    • pp.130-139
    • /
    • 2013
  • In recent, the communication networks of wind power farm are becoming crucial technologies for monitoring and controlling the large-scale offshore wind power farm. In this paper, EPON based communication network architectures are proposed in order to combat the problems of conventional Ethernet based communication network such as delay, data processing overhead and the fairness of data transmission among turbines in offshore wind power farm. The proposed architecture constructs the point to multi-point network by using OLT and ONUs installed in central control center and wind turbines respectively. The EPON based communication network architecture has low cost, high reliability, and fair transmission capability. To evaluate the performance of proposed architectures, the wind power farm based on IEC 61850 is modelled by using OPNET The simulation results are analyzed and compared with conventional Ethernet based communication network in terms of the overhead, delay and fairness of data transmission.

Development of Message Broker-Based Real-Time Control Method for Road Traffic Safety Facilities Equipment and Devices Integrated Management System

  • JeongHo Kho;Eum Han
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.1
    • /
    • pp.195-209
    • /
    • 2024
  • The current road traffic signal controller developed in the 1990s has limitations in flexibility and scalability due to power supply problems, various communication methods, and hierarchical black box structures for various equipment and devices installed to improve traffic safety for road users and autonomous cooperative driving. In this paper, we designed a road traffic safety facilities equipment and devices integrated management system that can cope with the rapidly changing future traffic environment by solving the using direct current(DC) and power supply problem through the power over ethernet(PoE) technology and centralized data-driven control through message broker technology. In addition, a data-driven real-time control method for road traffic safety facilities equipment and devices operating based on time series data was implemented and verified.

Application and performance evaluation of mass balance method for real-time pipe burst detection in supply pipeline (도수관로 실시간 관파손감지를 위한 물수지 분석 방법 적용 및 성능평가)

  • Eunher Shin;Gimoon Jeong;Kyoungpil Kim;Taeho Choi;Seon-ha Chae;Yong Woo Cho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.6
    • /
    • pp.347-361
    • /
    • 2023
  • Water utilities are making various efforts to reduce water losses from water networks, and an essential part of them is to recognize the moment when a pipe burst occurs during operation quickly. Several physics-based methods and data-driven analysis are applied using real-time flow and pressure data measured through a SCADA system or smart meters, and methodologies based on machining learning are currently widely studied. Water utilities should apply various approaches together to increase pipe burst detection. The most intuitive and explainable water balance method and its procedure were presented in this study, and the applicability and detection performance were evaluated by applying this approach to water supply pipelines. Based on these results, water utilities can establish a mass balance-based pipe burst detection system, give a guideline for installing new flow meters, and set the detection parameters with expected performance. The performance of the water balance analysis method is affected by the water network operation conditions, the characteristics of the installed flow meter, and event data, so there is a limit to the general use of the results in all sites. Therefore, water utilities should accumulate experience by applying the water balance method in more fields.

Advanced protocol against MITM attacks in Industrial Control System (산업제어시스템에서의 MITM 공격을 방어하기 위해 개선된 프로토콜)

  • Ko, Moo-seong;Oh, Sang-kyo;Lee, Kyung-ho
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.25 no.6
    • /
    • pp.1455-1463
    • /
    • 2015
  • If the industrial control system is infected by malicious worm such as Stuxnet, national disaster could be caused inevitably. Therefore, most of the industrial control system defence is focused on intrusion detection in network to protect against these threats. Conventional method is effective to monitor network traffic and detect anomalous patterns, but normal traffic pattern attacks using MITM technique are difficult to be detected. This study analyzes the PROFINET/DCP protocol and weaknesses with the data collected in real industrial control system. And add the authentication data field to secure the protocol, find out the applicability. Improved protocol may prevent the national disaster and defend against MITM attacks.