• 제목/요약/키워드: SCADA Security

검색결과 92건 처리시간 0.028초

한국형 계통운영시스템 간 보안을 고려한 ICCP/TASE.2 개발

  • 박성완;김진철;김상태;이승원
    • 정보보호학회지
    • /
    • 제25권5호
    • /
    • pp.67-73
    • /
    • 2015
  • 한국형 계통운영시스템인 전력거래소(KPX)의 EMS(Energy Management System)와 한국전력공사(이하 한전)의 급전소 SCADA시스템은 서로 ICCP(Inter-Control Center Protocol)를 통한 데이터 교환을 하고 있다. 현재의 ICCP는 데이터 교환에 있어서 보안 기능이 고려되어 있지 않기 때문에 본 논문에서는 안전하고 신뢰성 있는 계통운영시스템 간 데이터 교환을 위한 ICCP/TASE.2의 보안 통신 기능 개발을 소개하고자 한다.

네트워크 기반 자동화 변전소에서 SOAP을 이용한 IED간 정보교환기술 연구 (A Study on the Information Exchange Technology Between IEDs Using SOAP in Network Based Substation Automation System)

  • 고윤석
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권9호
    • /
    • pp.376-383
    • /
    • 2006
  • In this paper, autonomous information exchange methodology is studied between IEDs using SOAP protocol based on XML and PtP communication to archive the safety and reliability of large-scale system operation. The SOAP protocol has the advantages in the independency Problem for operating systems, using language, platforms and the security problem because it is XML-based RPC protocol. Inference-based solution of the IED is designed as rule-based solution so that the IED internal status, the system status or the faulted zone can be inferred autonomously using the internal data as well as information data obtained from free information exchange among other IEDS, Also, it is designed so that the inference results and the operation information are transmitted to the above SCADA system, and determined autonomously whether the commands from the SCADA are executed or not. Finally, The inference-based solution of IED and information exchange system among IEDS is implemented using MS Visual C++ MFC, MS SOAP and MS XML. Availability and accuracy of the proposed methodology and the design is verified from diversity simulation reviews for typical distribution substation.

765kV 변전소 감시제어용 시범시스템 (Design of a Prototype Fibre Optic Based Monitoring and Control System for Future KEPCO's 765kV Substation)

  • 장문명;정상진;최종협;박종명
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.883-886
    • /
    • 1996
  • Instead of point-to-point hard wiring between substation yard equipments and SCADA RTU(Remote Terminal Unit), fibre optic cable will be used in the portion between Local Units and Central Unit in the future KEPCO 765kV substation. The connections between substation yard equipments and nearby Local Unit remain the same hard wiring. The new fibre optic system will provide security especially during ground faults and is immune to electrical noise. A prototype system will be manufactured and installed in the existing 154kV Yeosan Substation by the end of July this year and operated for one year. By incorporating the operation experiences acquired in the system, an improved system will be commercially applied to 765kV Shin-An-Seong Substation where 345kV GIS will be installed initially and act as the switching station in the year 1998. The system is composed of one Central Unit and several Local Units. The Central Unit is composed of two workstation level computers, one is in operation and the other backup, and a Communication Control Unit. The Local Unit uses the existing SCADA RTU technology and takes the form of a distributed one. Between the Communication Control Unit and Local Units, the fibre optic system with star-coupler is used.

  • PDF

보안측면에서의 산업제어시스템 비정상 행위 분류 (Classification of ICS abnormal behavior in terms of security)

  • 나중찬;조현숙
    • 정보보호학회논문지
    • /
    • 제23권2호
    • /
    • pp.329-337
    • /
    • 2013
  • 산업제어시스템의 사이버위협 특징은 의도하지 않았다고 하더라도 피해범위가 특정 시스템뿐만 아니라 네트워크의 서비스 제공을 위협하는 수준에 도달했다는 점이다. '보안'의 일부 범위는 단지 테러리스트나 사이버 해커의 고의적인 공격에 대한 시스템의 보호를 포함하지만, 종종 더 큰 피해는 의도적인 공격보다 부주의에 의한 설정 오류 또는 장비고장 등의 비고의적인 행위로 이루어 진다. 본 논문은 고의적 공격, 실수, 장비 고장 및 소프트웨어 문제를 포함한 ICS의 모든 비정상 행위에 대한 분류를 제안하였다. ICS의 비정상 행위 분류 기준은 고의적인 공격뿐만 아니라 부주의한 행동의 공통점과 중요한 특징을 강조하기 위해 선정되었다.

보안을 고려한 무중단 환경에서 개발운영조직 통합관리(DevOps)

  • 전인석
    • 정보보호학회지
    • /
    • 제25권1호
    • /
    • pp.47-52
    • /
    • 2015
  • 보안에서 인적보안(Personal Security)의 예방통제 중 하나로 개발/운영을 분리하는 직무분리(Separation of Duty)를 해오고 있다. 고의적인 시스템의 오용을 줄이기 위한 방법이며, 많은 국제 표준과 국내 표준(COBIT, ISMS, 등)에서 직무분리를 명시하고 있다. 하지만 무중단 시스템이면서, 운영자가 특정 전문가 집단으로 한정되고, 수 많은 변경이 발생하는 무중단 환경에서 개발/운영이 분리 됨으로 인한 여러 가지 문제점이 발생 하고 있다. 체계를 운영하면서 전문지식을 기반으로 한 요구사항을 명확하게 이해하지 못하면, 추가적인 요구사항이 발생한다. 이는 체계의 품질저하와 위험(Risk)증가로 이어지게 된다. 따라서 본 연구에서는 개발운영조직 통합관리(DevOps) 방법론을 SCADA와 같이 운영자가 해당 분야의 전문성을 가지고, 무중단으로 운영되며, 수많은 변경이 반영되는 시스템에서 개발 및 운영을 통합하였을 때, 발생할 수 있는 문제점과 개선방안을 제시하고자 한다.

Optimal WAMS Configuration in Nordic Power System

  • Mohamed A.M. Hassan;Omar H. Abdalla;Hady H. Fayek;Aisha H.A. Hashim;Siti Fauziah Toha
    • International Journal of Computer Science & Network Security
    • /
    • 제23권3호
    • /
    • pp.130-138
    • /
    • 2023
  • The Smart grids are considered as multi-disciplinary power systems where the communication networks are highly employed. This paper presents optimal wide area measurement system (WAMS) configuration in Nordic power system. The transition from SCADA to WAMS becomes now trend in all power systems to ensure higher reliability and data visibility. The optimization applied in this research considered the geographical regions of the Nordic power system. The research considered all the devices of WAMS namely phasor measurement units (PMUs), phasor data concentrators (PDCs) and communication links. The study also presents two scenarios for optimal WAMS namely base case and N-1 contingency as different operating conditions. The result of this research presents technical and financial results for WAMS configuration in a real power system. The optimization results are performed using MATLAB 2017a software application.

산업제어시스템 정보보안 감리 프레임워크 연구 (Information security auditing Framework in Industrial control system)

  • 이철수
    • 정보보호학회논문지
    • /
    • 제18권1호
    • /
    • pp.139-148
    • /
    • 2008
  • 정보기술의 발전은 비즈니스 환경의 변화는 물론 대형 산업 시설의 자동화에 많은 변화를 가져왔다. 전력, 수자원, 에너지, 교통, 통신, 등은 국가의 안보와 국민 생활의 안정 그리고 국가 경제발전의 기반을 형성하는 국가의 주요 기반시설이며 이들 모두 산업제어 시스템에 의해 통제되고 있다. 또 비즈니스 환경의 변화는 조직의 모든 시스템을 통합하고 있어 경영정보시스템과 산업제어 시스템의 통합이 이루어지고 있다. 이에 따라 산업제어 시스템의 표준화와 개방형 시스템으로 전환이 이루어지고 있어 더욱 보안의 중요성이 커지고 있다. 제어시스템 보안에 대한 연구가 기술, 관리, 환경 등 다양한 분야에서 추진되고 있다. 그럼에도 제어시스템 감사에 대한 연구는 아직 미약하다. 정부는 최근 정부 및 주요 공공 시스템에 대한 정보시스템 감리를 의무화하여 안정성, 효율성, 효과성을 평가하고 있다. 또 주요정보통신기반시설에 대해서는 취약점 분석을 하고 그 개선 작업을 하도록 의무화하고 있다. 그럼에도 제어시스템에 대한 감리를 하지 않고 있고 제어시스템에 대한 보안 아키텍처나 감리 프레임워크도 준비되어 있지 않다. 본 연구는 제어시스템 감리를 위한 정보보안 아키텍처와 정보보안 감리 프레임워크를 제시하여 감리의 기반을 마련하였다.

제어시스템 사이버 보안 교육훈련 방안 연구 (A Study on Control System Cyber Security Education & Training Method)

  • 김경호;맹영재;장문수;류재철
    • 정보보호학회논문지
    • /
    • 제29권3호
    • /
    • pp.645-656
    • /
    • 2019
  • 제어시스템에 대한 사이버 위협 사례가 증가함에 따라 제어시스템 사이버 보안에 대한 필요성이 증가하고 있다. 현재 국내외에서 다양한 사이버 보안 관련 교육과 제어시스템 관련 교육이 수행되고 있다. 그러나 제어시스템의 특성과 참가자의 특성을 온전히 반영하기에 아쉬움이 있다. 본 논문에서는 제어시스템의 특성을 반영하기 위하여 다양한 제어시스템을 분석하였다. 분석 내용과 IEC62443에서 제시된 제어시스템 모델을 이용하여 제어시스템 훈련 환경을 제안한다. 그리고 참가자의 학습 성과를 향상하기 위해 참가자 특성을 분석하고, 교육 분야의 ARCS 학습 모델을 활용한 융합소통 훈련 기법을 제안하였다. 그리고 제안한 훈련환경과 훈련기법을 이용한 교육훈련 시나리오를 제시하였다. 제안한 내용을 통해 보안전문가와 제어시스템 전문가의 상호 이해를 바탕으로 한 협업 모델을 실무에 적용하여 최종적으로 제어시스템 사이버 보안 능력을 향상시킬 수 있을 것이라고 기대한다.

Sysmon과 ELK를 이용한 산업제어시스템 사이버 위협 탐지 (Cyber-Threat Detection of ICS Using Sysmon and ELK)

  • 김용준;손태식
    • 정보보호학회논문지
    • /
    • 제29권2호
    • /
    • pp.331-346
    • /
    • 2019
  • 국내 외에서 산업제어시스템을 대상으로 한 사이버 위협이 증가하고 있다. 이에 따라 관련 연구와 협력이 활발히 진행되고 있다. 하지만 물리적인 망 분리와 경계선에 대한 보안을 강화에 치중하고 있어 내부에서 발생하는 위협에 대해서는 여전히 취약한 편이다. 왜냐하면, 가장 손쉽고 강력한 대응방법이 경계선 보안을 강화하는 것이며 내부의 보안을 강화하기 위한 솔루션들은 시스템의 가용성 문제로 인하여 적용이 쉽지 않기 때문이다. 특히, 산업제어시스템 전반에 걸쳐 레거시 시스템이 상당수 잔존하고 있어 취약점이 많이 존재하고 있다. 이러한 취약한 시스템들이 보안 프레임워크에 따라 새롭게 구축되지 않는 한 이에 대한 대응방안이 필요함에 따라 가용성을 고려한 보안 솔루션을 검증하고 활용방안을 제시하였다. Sysmon과 ELK를 이용하는 방법으로 보안 솔루션이 미구축된 산업제어시스템에서 탐지하기 어려운 사이버 위협을 탐지할 수 있다.

이중화 자동복구 보안기능이 구비된 배전반의 보안성 평가를 위한 테스트베드 구성에 대한 고찰 (An Inquire into Test Bed Compositions in Assessing the Security of a Soft Redundancy Sub-Station System with Auto-Restoration)

  • 최형석;진창기;배기덕
    • 조명전기설비학회논문지
    • /
    • 제26권7호
    • /
    • pp.99-109
    • /
    • 2012
  • Sub-station, key equipment in electric power infrastructure, are being exposed to increasing risk of hacking. For this, soft redundancy sub-station system needs to be formulated with automatic restoration mechanism. For this it is important to assess the reliability of the applicable range of data that are used in actual system operation, as well as the methods and findings of the tests. At the same time performance of soft redundancy system and total security mechanism, which are aligned for the protection of the sub-station, need to be tested. For testing the above-mentioned, this paper presented a viable formation of a soft redundancy practical VPN system within a panel to protect the latter from hacking or cracking incidences, and conducts a test to check if the considered system actually serves the protection function in the actual operation setting, gathering evidence from the data from the testing of the actual performance of the system as well as of emergency scenario simulation operations. Because tested soft-redundancy & restorative sub-station system is expected to be widely applicable for various cases such as Smart-grid or electricity IT system, where VPN with enhanced level of security is required.