• Title/Summary/Keyword: S-Parameter Measurement

Search Result 379, Processing Time 0.031 seconds

The prognostic value of median nerve thickness in diagnosing carpal tunnel syndrome using magnetic resonance imaging: a pilot study

  • Lee, Sooho;Cho, Hyung Rae;Yoo, Jun Sung;Kim, Young Uk
    • The Korean Journal of Pain
    • /
    • v.33 no.1
    • /
    • pp.54-59
    • /
    • 2020
  • Background: The median nerve cross-sectional area (MNCSA) is a useful morphological parameter for the evaluation of carpal tunnel syndrome (CTS). However, there have been limited studies investigating the anatomical basis of median nerve flattening. Thus, to evaluate the connection between median nerve flattening and CTS, we carried out a measurement of the median nerve thickness (MNT). Methods: Both MNCSA and MNT measurement tools were collected from 20 patients with CTS, and from 20 control individuals who underwent carpal tunnel magnetic resonance imaging (CTMRI). We measured the MNCSA and MNT at the level of the hook of hamate on CTMRI. The MNCSA was measured on the transverse angled sections through the whole area. The MNT was measured based on the most compressed MNT. Results: The mean MNCSA was 9.01 ± 1.94 ㎟ in the control group and 6.58 ± 1.75 ㎟ in the CTS group. The mean MNT was 2.18 ± 0.39 mm in the control group and 1.43 ± 0.28 mm in the CTS group. Receiver operating characteristics curve analysis demonstrated that the optimal cut-off value for the MNCSA was 7.72 ㎟, with 75.0% sensitivity, 75.0% specificity, and an area under the curve (AUC) of 0.82 (95% confidence interval [CI], 0.69-0.95). The best cut off-threshold of the MNT was 1.76 mm, with 85% sensitivity, 85% specificity, and an AUC of 0.94 (95% CI, 0.87-1.00). Conclusions: Even though both MNCSA and MNT were significantly associated with CTS, MNT was identified as a more suitable measurement parameter.

Solubility of Hydrogen Sulfide in Aqueous Solutions of Methyldiethanolamine and diethanolamine

  • Park, Moon-Ki;Moon, Yung-Soo;Kim, Jung-Ho
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.3 no.2
    • /
    • pp.131-136
    • /
    • 1999
  • The solubility of H2S is an important parameter for modeling H2S absorption. Since the direct measurement of H2S solubility in aqueous amine solutions is impossible, this work initially attempted to develop an H2S analogy method, however, this was unsuccessful. Consequently, H2S solubilities were measured in aqueous amines which were completely protonated with HCI over a temperature range of 25-60℃. The solvents investigated in this work included 0-50% aqueous solutions of methyldiethanolamine and diethanolamine. Thereafter, a new empirical correlation was developed that can predict Henry's constant for H2S using only the solubility of H2S in water and t도 molecular weight of the aqueous solvent.

  • PDF

Comparison of Antenna Parameters of R-/S-Band Standard Gain Horn Antennas

  • Kang, Jin-Seob;Kim, Jeong-Hwan;Park, Jeong-Il
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.4
    • /
    • pp.224-231
    • /
    • 2015
  • A comparison of the antenna parameters for R-band (1.7-2.6 GHz) and S-band (2.6-3.95 GHz) standard gain horn antennas has been performed by the Korea Research Institute of Standards and Science (KRISS), together with seven domestic participants from private companies and public institutions. Its purpose, as a proficiency test program of the 'Antenna Measurement Club' of KRISS, was to check equivalences in antenna parameter measurements between KRISS and the participants, particularly in the R-/S-band, to support antenna manufacturers and end users in Korea. The measurement parameters of this comparison are the power gain, radiation pattern, and reflection coefficient of the traveling standards for R-/S-band pyramidal standard gain horn antennas. The comparison used a gain comparison method and an extrapolation method to measure the power gain of the two traveling standards; the radiation patterns were measured in the far-field region of the transmitting and receiving antennas.

Vector Network Analysis Using a One-Path, Frequency-Multiplied Photonic Link

  • Lee, Dong-Joon;Kwon, Jae-Yong;Kang, Jin-Seob;Whitaker, John F.
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.4
    • /
    • pp.282-289
    • /
    • 2010
  • A simplified, practical vector network analyzer (VNA) that uses mature radio-over-fiber technology has been designed and demonstrated. The measurement concept allows the full S-parameters of a microwave device (or antenna) to be obtained while minimizing the detrimental effects of electrical cables, which are replaced with a photonic link. A variety of high-frequency light modulation schemes with frequency sweeping capabilities are presented to realize a one-path (single, forward), frequency-multiplied optical link for VNA applications. Using the photonic one-path link, full two-port S-parameters have been extracted based on five-term error modeling, which has half the error terms compared with the standard duplex configuration. The S-parameters of a microwave filter and antenna measured using frequency-multiplied optical links are found to be in good agreement with those obtained using a conventional VNA.

Vibration Measurements of the Foot-Bridges Using Mobile-Phone (휴대용 계측기를 이용한 보도교 진동계측분석)

  • Do, Ki-Young;Yoon, Sung-Won;Kim, Do-Hyun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.14 no.1
    • /
    • pp.61-68
    • /
    • 2014
  • The design of foot-bridge is often influenced by natural frequency. Consequently, vibration frequency becomes important. The empirical expressions used to quantify this parameter at the design phase have not been developed enough to give guideline to Korean foot-bridge. This paper is concerned with the vertical natural frequency of steel foot-bridges. It describes the vibration measurement methods employed for testing structures and presents reliable methods of assessing natural frequency from jumping vibration tests. Data from measurements on 16 structures in Seoul are given. Regression formulas of natural frequency for steel-framed foot-bridges are suggested. Finally, obtained formula are compared with empirical expressions of Seoul City's guideline.

Formulation, Measurement and Analysis for the Static Thrust of LPM (LPM의 정추력 정량화 및 측정 분석)

  • Kim D.H.;Bae D.K.;Kim K.H.;Park H.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.304-307
    • /
    • 2003
  • Usually, the thrust of a Linear Pulse Motor(LPM) is calculated by magnetic equivalent circuit modelling method. Analytical thrust deviation exists to calculating magnetic flux density by using Permeance Modelling Method, Finite Element Method, and Velocity Electric Motive Force method. For calculating accuracy thrust by using these every method, tire thrust is calculated and compared by Lorentz Force method, Magnetic coenergy Method, and Maxwell correspondence forte Method. And that becomes Important factor at the comparison of each capacity and parameter of motor. So this study wants to compare and analyze measurement data and calculating data of the static thrust of LPM. and then we can get more accuracy method, calculating the static thrust of LPM.

  • PDF

A Experimental study on natural frequency measurement of passenger car tire under the load and rotation (하중을 받고 회전하는 승용차 타이어의 고유진동수 측정에 관한 실험적 연구)

  • 김병삼;홍동표;김동현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.601-606
    • /
    • 1993
  • The natural frequency measurement of passenger car tire under the load and rotation are studied. In order to obtain theoretical natural frequency and mode shape, the plane vibration of a tire is modeled to that of circular beam. By using the Tickling method based on Hamilton's principle, theoretical results are determined by considering tension force due to tire inflation pressure, rotational velocity and tangential, radial stiffness. Modal parameters varying the inflation pressure, load, rotational velocity are determined experimentally by using frequency response function method. The results show that experimental conditions are parameter for shifting of natural frequency.

  • PDF

A "Thru-Short-Open" De-embedding Method for Accurate On-Wafer RF Measurements of Nano-Scale MOSFETs

  • Kim, Ju-Young;Choi, Min-Kwon;Lee, Seong-Hearn
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.12 no.1
    • /
    • pp.53-58
    • /
    • 2012
  • A new on-wafer de-embedding method using thru, short and open patterns sequentially is proposed to eliminate the errors of conventional methods. This "thru-short-open" method is based on the removal of the coupling admittance between input and output interconnect dangling legs. The increase of the de-embedding effect of the lossy coupling capacitance on the cutoff frequency in MOSFETs is observed as the gate length is scaled down to 45 nm. This method will be very useful for accurate RF measurements of nano-scale MOSFETs.

Development of Real Time Digital Peripheral Plethysmography (실시간 디지털 사지 혈류량 측정기 개발)

  • Kim, S.C.;Kim, D.W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.424-427
    • /
    • 1997
  • Electrical impedance plethysmography is still be one of the simplest and most convenient methods or non-invasive measurement of blood low, but it has the weak point can not do real-time measurement because of using chart-record or processing after receiving data from analog plethysmography through A/D converter. In this study. we developed hardware system composed of analog part which include auto-balancing circuit and calibration register and digital part which include 80C196KC, keypad, and LCD. we studied the algorithms or extracting parameter to calculate blood low and implemented it using general purpose micro controller.

  • PDF

Determination of Korean Weighted Mean Temperature for Calculation of Tropospheric Zenith Hydrostatic Delay (대류권 천정 방향 건조 지연량 계산을 위한 우리나라 가중 평균 온도식 결정)

  • 송동섭;황학;윤홍식
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.11a
    • /
    • pp.47-53
    • /
    • 2004
  • Water vapor is an important parameter in monitoring changes in the Earth's climate and it can be used to improve weather forecasting However, it haven't observed accurately by reasons of structural and economic problem of observation. GPS meteorology technique for precipitable water vapor measurement is currently actively being researched an advanced nation. Main issue of GPS meteorology is an accuracy of PWV measurement related weighted mean temperature and meteorological data. In this study, the korean weighted mean temperature had been recalculated by a linear regression method based on meteorological observations from 6 radiosonde stations for 2003 year. We examined the accuracy of PWV estimates from GPS observations and Radiosonde observations by new korean weighted mean temperature and others.

  • PDF