• Title/Summary/Keyword: S/R Valve

Search Result 122, Processing Time 0.029 seconds

An experimental study on the characteristics of the swirl ratio distribution with an intake port geometry (흡기포트 형상에 따른 선회비 분포특성에 관한 실험적 연구)

  • Lee, Ji-Geun;Ju, Bong-Cheol;No, Byeong-Jun;Gang, Sin-Jae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.6
    • /
    • pp.725-734
    • /
    • 1997
  • The effect of helical intake port geometry on in-cylinder swirl flow characteristics was studied. Two helical intake ports were selected to change swirl ratio, mean flow coefficient with the variation of valve lifts, valve eccentricity ratios and axial distance. The measurements were made by using an impulse swirl meter. The port B modified to increase the swirl ratio( $R_{s}$) had the tendency of the increased non-dimensional rig swirl ( $N_{r}$) distribution in comparison with that of the port A. And the $N_{r}$ distribution was remarkably improved at low valve lifts. The modification of the geometry to increase the swirl ratio ( $R_{s}$) in helical intake port resulted in the decrease of the mean flow coefficient ( $C_{f(mean)}$) regardless of valve eccentricity ratio ( $N_{y}$). And also non-dimensional rig swirl ( $N_{r}$) in the high valve lift affected the calculation of swirl ratio considerably.onsiderably.

The Effect of Curvature Radius and Material of Diaphragm on the Valve Opening Time in Diaphragm Type S/R Valve (S/R 밸브에서 격막의 곡률반경과 재료가 밸브 개구시간에 미치는 영향)

  • Cheon, Heung-Kyun;Hwang, Jae-Gun;Cho, Tae-Seok;Kwon, Young-Doo;Kwon, Soon-Bum
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2961-2966
    • /
    • 2007
  • When the pressure at the weak spot established at a certain part of a high pressure vessel or piping system exceeds a design pressure, this weak spot is burst, and the pressurized gas emitted through the weak spot will cause a compression wave system. In this connection, in the present study, an experimental study by using a conventional shock tube facility is performed to estimate the effects of the material of diaphragm, curvature radius and thickness of materials on the valve opening time in diaphragm. Pressure sensor having 500kHz in natural frequency is installed at 35mm downstream of the rupture diaphragm to measure the static pressure history of propagating and being accumulated compression wave. 4 kinds of materials are used as diaphragm that is aluminium, copper, stainless steel and zinc. The diaphragm radii of curvature R are ${\infty}$, 120mm and 60, respectively. And the depth for $90^{\circ}$ groove is 0.04mm. It is found that the smaller the tensile strength and elongation of the rupture diaphragm is, the smaller the radius of curvature of the rupture diaphragm is, and for the same conditions the thinner the thickness of the rupture diaphragm is, the shorter the valve opening time becomes. Also, the tensile strength, elongation and the radius of curvature of the rupture diaphragm for the same conditions are smaller, the maximum pressure rise caused by the coalescences of the compression wave is smaller. Finally the pressure ratio is higher, the valve opening time is shortened and gradient of pressure increment is more steepen.

  • PDF

Changes of Mitral Regurgitation after Aortic Valve Replacement, according to the Aortic Valve Pathology (대동맥 판막 치환술 후 대동맥 판막 병변에 따른 승모판막 폐쇄부전의 변화)

  • Kim, Si-Wook;Lee, Young-Tak;Jun, Tae-Gook;Sung, Ki-Ick;Kim, Wook-Sung;Yang, Ji-Hyuk;Choi, Jin-Ho;Park, Pyo-Won
    • Journal of Chest Surgery
    • /
    • v.40 no.10
    • /
    • pp.667-673
    • /
    • 2007
  • Background: Patients with severe aortic valve disease frequently display mitral valve regurgitation (MR). In such patients, the clinical course of MR after isolated aortic valve replacement (AVR) may be important for determining the treatment strategies. After isolated AVR, the change of the concomitant moderate degree or less of MR according to the type of aortic valve disease is not known well. The aim of this study was to analyze the post-operative changes of MR after performing AVR in those patients with severe AS (Group S) and those with severe AR (Group R). Material and Method: We retrospectively evaluated 43 patients with severe aortic disease and a moderate degree or less of mitral valve regurgitation, and these patients underwent isolated aortic valve replacement from January 1996 to June 2005. The patients were divided into two groups: the aortic valve stenosis group (n = 29) and the aortic valve regurgitation group (n = 14). The patients underwent transthoracic echocardiography preoperatively and at 7 days, $6{\sim}10$ months and more than 18 months (mean follow-up duration: 38 months) postoperatively. Result: The mean age was 60.9 years (Group S: 62 years, Group R: 52.5 years) and 60% (Group S=55%, Group R=71%) of the patients were male. The preoperative MR was mild in 29 (67.5%), mild to moderate in 11 (25.5%), and moderate in 3 (6.9%) patients. In the Group S patients, MR improved in 16 (55%) patients at the immediate postoperative days and in 17 (59%) patients at more than 18 months postoperatively. On the other hand, all the Group R patients exhibited earlier improvement. The decrease of LA size had a similar pattern to the MR change, but there were no significant differences in the change of the ejection fraction of the two groups. Conclusion: In the patients with severe aortic valve disease and concomitant low grade MR, the MR after AVR improved earlier and more effectively in the patients with AR than in those patients with AS.

Development of Valve Balance Test Equipment for Power Steering Gear (파워 스티어링 기어의 밸브 밸런스 테스트 장비 개발)

  • Go, S.J.;Park, M.K.;Won, T.H.;Kim, H.S.;Kim, K.H.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.1
    • /
    • pp.65-71
    • /
    • 2011
  • Steering gear is the part of an automobile that change circular movement of steering wheel to lateral movement of rack to change driving direction. This can be classified with manual and power steering gear. Manual steering gear is operated only with human power while power steering gear use oil pressure support. These days power steering gear is more common to almost of the car. Recently a korean company manufactures a speed sensitive power steering which provide variable steering feel depend on the speed of car. The Broens company of Australia produces and exports the test equipments for the manufacture of power steering valves and assemblies to major vehicle manufactures. Some korean companies imported the test equipments from Australia, thus increasing the cost. The purpose of this study is development of the valve balance test equipment to measure the valve torque of the power steering gear. This study designed and manufactured the valve balance test equipment to take hold of the power steering valve using CAE analysis. In order to evaluate the performance of the developed valve balance test equipment, the R&R tests have been conducted.

Characteristics of a Flow Control Valve for a Submerged Cargo Pumping System (서브머지드 카고 펌프 시스템용 유량제어밸브의 특성)

  • Lee, I.Y.;Choi, S.R.;Lee, D.R.;Park, H.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.6 no.2
    • /
    • pp.7-13
    • /
    • 2009
  • This study specifies the flow control characteristics of a flow control valve(FCV) in a submerged cargo pumping system through experiments and simulations. In the experiments, the functions of the major components of the FCV in relation to the FCV's flow characteristics are presented clearly. Through the simulations, it is shown that the simulation program suggested in this study can be utilized for the design of the FCV.

  • PDF

A Study on the Effects of Intake Port Eccentricity on the In-cylinder Swirl Ratio Characteristics in a 4 Valve Diesel Engine (4밸브 디젤기관의 흡기포트 편심이 실린더 내 선회비 특성에 끼치는 영향에 관한 연구)

  • 이지근;강신재;노병준
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.5
    • /
    • pp.157-169
    • /
    • 1997
  • The effects of intake port eccentricity on the characteristics of in-cylinder swirl ratio in a 4-valve diesel engine having the two intake ports; one is a helical intake port and the other is a tangential intake port were investigated by using the ISM(impulse swirl meter) in steady flow test rig. Swirl ratio($R_s$) and mean flow coefficient($C_{f(mean)}$) with valve eccentricity ratio($N_y$) and axial distance(Z/B) were measured. As the results from this experiment, the characteristics of in-cylinder swirl ratio formed by a 4-valve cylinder head were largely affected by intake port eccentricity. There is a difference in the mass flowrate through the two intake ports, and the mass flowrate through the tangential intake port is 19% more than that of the helical intake port. Therefore, we could know that the effects of the mass flowrate ratio through each intake port besides intake port shape should be conidered.

  • PDF

A study on the effects of intake port eccentricity and a partition between the two intake ports on the in-cylinder swirl characteristics in a valve diesel engine (4밸브 디젤기관의 흡기포트 편심과 두 흡기포트 사이의 격막이 실린더 내 선회 특성에 미치는 영향에 관한 연구)

  • Lee, Ji-Geun;Gang, Sin-Jae;No, Byeong-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.7
    • /
    • pp.948-961
    • /
    • 1997
  • The effects of intake port eccentricity and a partition between the two intake ports on the incylinder swirl characteristics in a 4 valve diesel engine having the two intake ports, one is a helical intake port and the other is a tangential intake port, were investigated by using the impulse swirl meter(ISM) in a steady flow test rig. Mean flow coefficient ( $C_{f(mean)}$, swirl ratio ( $R_{s}$) and the mass flowrate through the two intake ports with and without intake port partition were measured. The results showed that the characteristics of in-cylinder swirl ratio formed by a 4-valve cylinder head were largely affected by valve eccentricity ratio ( $N_{y}$) and the existence of an intake port partition between the two intake ports. Mean flow coefficient ( $C_{f(mean)}$) increases and swirl ratio ( $R_{s}$) decreases in case of being the partition between the two intake ports. And also the mass flowrate through the tangential intake port is 19.0% and 7.7% more than that of the helical intake port in case of the two intake ports with and without partition respectively.ively.

Measurement method for valve noise (밸브의 소음 측정 방법)

  • Lee, Y. B.;Yoon, B. R.;Kwon, H. S.;Park, K. A.;Yoo, S. H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.433-438
    • /
    • 2001
  • Noise is one of the major environmental problems in human life. To reduce the noise emitted from the control valve it is necessary to develop the measurement method, measurement system, analysis method applicable to the field. In this study IEC and ISO standards were investigated and measurement method for the valve noise was proposed. Noise from the valve was measured in the reverberation room and sound power level was calculated. The sound power level increased as the flow rate and pressure difference increased. The noise characteristics are useful to predict valve noise for given conditions, to compare the performance of different valves and to develope low-noise valves.

  • PDF

Operating Performance of Solenoid Valve and Nozzle Sets for Target Selectable Sprayers (이동형 국소 분무장치용 전자 밸브와 노즐 조합 작동특성)

  • Suh, S.R.;Kim, H.O.;Kim, Y.T.;Choi, Y.S.;Yoo, S.N.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.1 s.114
    • /
    • pp.39-45
    • /
    • 2006
  • Fundamental informations on performance of sets of solenoid valve and nozzle were necessary to develop a target selectable spraying system. The experiments were performed for the sets of solenoid valves and flat spraying nozzles at 3 levels of the operating pressures, and the obtained results are as follows; Rise time of the system pressure to reach up to 90% of the operating pressure after the valve turned was affected by nozzle size and operating pressure. Maximum overshoot of the system pressure was about 170% not affected by the sets of valve and nozzle and operating pressure. The system pressure after its settle down within 5% of the set pressure showed good uniformity in any condition of the experiment as less as 2.3% of its coefficient of variation. Time requirement to lower the system pressure down to 50% after the valve power turned off was affected by valve and nozzle set and operating pressure.