Abstract
Fundamental informations on performance of sets of solenoid valve and nozzle were necessary to develop a target selectable spraying system. The experiments were performed for the sets of solenoid valves and flat spraying nozzles at 3 levels of the operating pressures, and the obtained results are as follows; Rise time of the system pressure to reach up to 90% of the operating pressure after the valve turned was affected by nozzle size and operating pressure. Maximum overshoot of the system pressure was about 170% not affected by the sets of valve and nozzle and operating pressure. The system pressure after its settle down within 5% of the set pressure showed good uniformity in any condition of the experiment as less as 2.3% of its coefficient of variation. Time requirement to lower the system pressure down to 50% after the valve power turned off was affected by valve and nozzle set and operating pressure.
Keywords
Solenoid valve and nozzle; Selective spraying; Timing of valve operation;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Baio, F. H. R. and L. A. Balastreire. 2002. Evaluation of a site specific chemical application system based on the spatial variability of weeds. Proceedings of the World Congress of Computers in Agriculture and Natural Resources, pp. 225-231
2 GopalaPillai, S., L. Tian and J. Zheng. 1999. Evaluation of a flow control system for site-specific herbicide applications. Trans. of the ASAE 42(4):863-870   DOI
3 Han, S, L. L. Hendrickson, B. Ni and Q. Zhang. 2001. Modification and testing of a commercial sprayer with PWM solenoids for precision spraying. Applied Engineering in Agriculture, ASAE 17(5):591-594
4 Kajima, Takashi and Yoshihisa Kawamura. 1995. Development of a high-speed solenoid valve: investigation of solenoid. IEEE Trans. on Industrial EIectronics 42(1): 1-8   DOI   ScienceOn
5 Spraying System Co. 2005. Data from internet web site: http://www.spray.com
6 Tian, L. 2002. Hitting the mark. Resource, ASAE April:11-12