• Title/Summary/Keyword: Routine Test

Search Result 468, Processing Time 0.031 seconds

Routine double-J stenting for live related donor kidney transplant recipients: It doesn't serve the purpose, but does it serve a better purpose?

  • Kumar, Vikash;Punatar, Chirag B;Jadhav, Kunal K;Kothari, Jatin;Joshi, Vinod S;Sagade, Sharad N;Kamat, Madhav H
    • Investigative and Clinical Urology
    • /
    • v.59 no.6
    • /
    • pp.410-415
    • /
    • 2018
  • Purpose: Despite meticulous techniques, surgical complications continue to be problematic in kidney transplant recipients. Role of routine stenting to reduce complications is controversial. In this study, we compare incidence of early urological complications, lymphoceles, urinary tract infections (UTI) and graft function; with or without double-J stenting. Materials and Methods: All patients who underwent live related donor renal transplantation from February 2014 to February 2016 were included. Transplants prior to February 2015 were without routine stenting; subsequent transplants were with routine stenting. Patients with neurogenic bladder, previously operated bladder and delayed or low urinary output were excluded. Followup was for at least three months. Descriptive statistics was performed for all parameters. Chi square test and Fisher's Exact test were used for qualitative variables. For quantitative variables, Mann-Whitney test was used to test median difference and independent samples t-test for mean difference. The p-value ${\leq}0.05$ was considered significant. Results: We analysed 74 patients (34 stented and 40 non-stented). There was no difference in the incidence of urinary leak, anastomotic obstruction, lymphoceles or UTI (p>0.4 for all comparisons). However, mean estimated glomerular filtration rate at sixth day, 14th day, one month and two months were 76.1 vs. 61.5 (p=0.025), 72.1 vs. 56.6 (p=0.005), 79.4 vs. 63.1 (p=0.002) and 82.0 vs. 63.3 (p=0.001) in the stented versus non-stented groups. Conclusions: Placement of ureteral stent in renal transplant does not significantly affect the incidence of early urinary complications or UTI. However, graft function is significantly better in stented recipients, at least in the short term.

Quantitative Analysis of Indomethacin by the Portable Near-Infrared (NIR) System (근적외분광분석법을 이용한 인도메타신의 정량분석)

  • 김도형;우영아;김효진
    • YAKHAK HOEJI
    • /
    • v.47 no.5
    • /
    • pp.261-265
    • /
    • 2003
  • Near-infrared (NIR) system was used to determine rapidly and simply indomethacin in buffer solution for a dissolution test of tablets and capsules. Indomethacin standards were prepared ranging from 10 to 50 ppm using the mixture of phosphate buffer (pH 7.2) and water (1 : 4). The near-infrared (NIR) transmittance spectra of indomethacin standard solutions were collected by using a quartz cell in 1 mm and 2 mm pathlength. Partial least square regression (PLSR) was explored to develop calibration models over the spectral range 1100∼1700 nm. The model using 1 mm quartz cell was better than that using 2 mm quartz cell. The PLSR models developed gave standard error of prediction (SEP) of 0.858 ppm. In order to validate the developed calibration model, routine analysis was performed using another standard solutions. The NIR routine analysis showed good correlation with actual values. Standard error of prediction (SEP) is 1.414 ppm for 7 indomethacin samples in routine analysis and its error was permeable in the regulation of Korean Pharmacopoeia (VII). These results show the potential use of the real time monitoring for indomethacin during a dissolution test.

The Clinical Use of Routine Urinalysis (기본 요분석검사의 임상적 이용)

  • Lee, Seung Joo
    • Childhood Kidney Diseases
    • /
    • v.17 no.2
    • /
    • pp.35-41
    • /
    • 2013
  • Routine urinalysis is a simple, economical, and useful test that facilitates the detection of urinary system diseases and monitoring of renal disease progression. It consists of 4 parts of specimen evaluation, gross examination, a dipstick urinalysis, and a sediment microscopic urinalysis. Urine specimens should first be evaluated in terms of acceptability, and thereafter, the gross appearance is examined for color, turbidity, and odor. In particular, a dipstick urinalysis is an easy and rapid test that provides information on the multiple physicochemical properties of the urine sample. Moreover, although a sediment microscopic urinalysis is time-consuming, it provides information on the cells, microorganisms, casts, and crystals. In the present report, the clinical significance of the routine urinalysis and the problems concerning interpretation are summarized.

Analysis of Ride Comfort Test Result for Passenger Coach (객차 승차감 측정 시험결과 분석)

  • Lee, Ji-Hoon;Lee, Chang-Hwan;Yoo, Wan-Suk
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.43-49
    • /
    • 2006
  • To design railway vehicles to ensure comfortable running, ride comfort of human exposed on vibrating carbody should be considered. Also, to improve ride comfort for passenger coach, many factors should be analysed and evaluated. There are many factors as suspension characteristics of railway vehicle, track characteristics to run etc. In this paper, passenger coach sujected to test on specific routine were evaluated using test results. Test routine were divided by 13 sections to analyse more detail. And the characteristics of every section were analysed distributions of radius curves, tunnel and bridge which could give impact to ride comfort. The evaluation of ride comfort were accomplished by UIC and ISO methods.

  • PDF

In-Use Compliance Emission Testing Analysis Applied in LabVIEW for Engineers

  • Mikhail, Ghaly-Rezk;Lee, Chun-Beom;Choi, Seong-Joo
    • Journal of Practical Engineering Education
    • /
    • v.6 no.2
    • /
    • pp.127-134
    • /
    • 2014
  • Analyzing test data of a vehicle for evaluating its emission performance is an essential process in automotive development field, yet it is intricate and tedious task. In addition, clear understanding and care are required when the analysis process is carried out. Computer software solutions significantly reduce the time and the effort for such analysis. Developing a computer routine to analyze the emission data in a vehicle test demands a complete understanding of the emissions analysis and its related details. In this paper, the principals to develop a LabVIEW analysis routine (VI) are introduced helping automotive engineers comprehend the emission analysis process of a vehicle test data and instruct them to develop similar routines for such analysis.

CRX-Hex: A Transport Theory Assembly Code Based on Characteristic Method for Hexagonal Geometry

  • Cho, Nam-Zin;Hong, Ser-Gi
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.28-33
    • /
    • 1996
  • A transport theory code CRX-Hex based on characteristic methods with a general geometric tracking routine is developed for the heterogeneous hexagonal geometry. With the general geometric tracking routine, the formulation of the characteristic method is not changed. To test the code, it was applied to two benchmark problems which consist of complex meshes and compared with other codes (HELIOS, TWOHEX).

  • PDF

$\mu\textrm{p}$-based Electronic Control System for Automobiles Part 2; Information Display Control System (자동차의 마이크로프로셋서를 이용한 전자식 제어시스템에 대한 연구 제2편 ; 정보 표시 제어장치)

  • Chae, S.;Kim, Y.L.;Liu, J.;Kim, K.R.;Bien, Zeungnam
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.17 no.6
    • /
    • pp.33-37
    • /
    • 1980
  • The information display control system is designed and implemented on an automobile in which the conventional panel displays are replaced by electronic ones. The system hardware consists of three main parts, i. e., (i) the function select keyboard (ii) the central processing unit (iii) the displays, The system software consists of main routine and several interrupt service routine such as keyboaiuand display interrupt service routine:. The main routine handles various sensor inputs to generate the appropriate information for the driver such as running speed, available fuel quantity. coolant temperature, battery voltage, remaining distance to the destination , time of day, and so on. Finally the results of the field test of the system and some associated difficulties of realization problems are discussed.

  • PDF

Automatic Multileaf Collimation Quality Assurance for IMRT using Electronic Portal Imaging

  • Jin, Ho-Sang;Jason W. Sohn;Suh, Tae-Suk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.305-308
    • /
    • 2002
  • More complex radiotherapy techniques using multi leaf collimation(MLC) such as intensity-modulated radiation therapy(IMRT) has been increasing the significance of verification of leaf position and motion. Due to the reliability and robustness, quality assurance(QA) of MLC is usually performed with portal films. However, the advantage of ease of use and capability of providing digital data of electronic portal imaging devices(EPIDs) have attracted many attentions as alternatives of films for routine quality assurance in spite of the concerns about their clinical feasibility, efficacy, and the cost to benefit ratio. In our work, the method of routine QA of MLC using electronic portal imaging(EPI) was developed. The verification of availability of EPI images for routine QA was performed by comparison with those of the portal films which were simultaneously obtained when radiation was delivered and known prescription input to MLC controller. Specially designed test patterns of dynamic MLC were applied to image acquisition. Quantitative off-line analysis using edge detection algorithm enhanced the verification procedure in addition to on-line qualitative visual assessment. In conclusion, the EPI is available enough for routine QA with the accuracy of portal films.

  • PDF