Quantitative Analysis of Indomethacin by the Portable Near-Infrared (NIR) System  

김도형 (동덕여자대학교 약학대학)
우영아 (동덕여자대학교 약학대학)
김효진 (동덕여자대학교 약학대학)
Publication Information
YAKHAK HOEJI / v.47, no.5, 2003 , pp. 261-265 More about this Journal
Abstract
Near-infrared (NIR) system was used to determine rapidly and simply indomethacin in buffer solution for a dissolution test of tablets and capsules. Indomethacin standards were prepared ranging from 10 to 50 ppm using the mixture of phosphate buffer (pH 7.2) and water (1 : 4). The near-infrared (NIR) transmittance spectra of indomethacin standard solutions were collected by using a quartz cell in 1 mm and 2 mm pathlength. Partial least square regression (PLSR) was explored to develop calibration models over the spectral range 1100∼1700 nm. The model using 1 mm quartz cell was better than that using 2 mm quartz cell. The PLSR models developed gave standard error of prediction (SEP) of 0.858 ppm. In order to validate the developed calibration model, routine analysis was performed using another standard solutions. The NIR routine analysis showed good correlation with actual values. Standard error of prediction (SEP) is 1.414 ppm for 7 indomethacin samples in routine analysis and its error was permeable in the regulation of Korean Pharmacopoeia (VII). These results show the potential use of the real time monitoring for indomethacin during a dissolution test.
Keywords
near-infrared spectroscopy; indomethacin; partial least square regression;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Near-infrared analytical control of pharmaceuticals. A single calibration model from mixed phase to coated tablets /
[ Blanco,M.;Coello,J.;Iturriaga,H.;Maspoch,S.;Serrano,D. ] / Analyst   DOI   ScienceOn
2 Automated system for the on-line monitoring of powder blending processes using near-infrared spectroscopy. Part Ⅱ. Qualitative approaches to blend evaluation /
[ Sekulic,S.S.;Wakeman,J.;Doherty,P.;Hailey,P.A. ] / J. Pharm. Biomed. Anal.   DOI   ScienceOn
3 Quality control in manufacturing process by near infrared spectroscopy /
[ Gonzalez,F.;Pous,R. ] / J. Pharm. Biomed. Anal.   DOI   ScienceOn
4 Identification and quantitation assays for intact tablets of two related pharmaceutical preparations by reflectance near-infrared spectroscopy: validation of the procedure /
[ Blanco,M.;Eustaquio,A.;Gonzalez,J.M.;Serrano,D. ] / J. Pharm. Biomed. Anal.   DOI   ScienceOn
5 A rapid quantitative assay of intact paracetamol tablets by reflectance near-infrared spectroscopy /
[ Trafford,A.D.;Jee,R.D.;Moffat,A.C.;Graham,P. ] / Analyst   DOI   ScienceOn
6 The application of nultiple linear regression to the measurement of the median particle size of drugs and pharmaceutical excipients by near-infrared spectroscopy /
[ D'Neil.A.J.;Jee,R.D.;Moffat,A.C. ] / Analyst   DOI   ScienceOn
7 Assay of effervescent tablets by near-infrared spectroscopy in transmittance and reflectance mode: acetylsalicylic acid in mono and combination formulations /
[ Merckle,P.;Kovar,K.A. ] / J. Pharm. Biomed. Anal.   DOI   ScienceOn
8 Identification of pharmaceutical excipients using NIR spectroscopy and SIMCA /
[ Candolfi,A.;De Maesschalck, R.;Massart,D.L.;Hailey,P.A.;Harrington,A.C. ] / J. Pharm. Biomed. Anal.   DOI   ScienceOn
9 Non-invasive determination of ethanol, propylene glycol and water in a multi-component pharmaceutical oral liquid by direct measurement through amber plastic bottles using Fourier transform near-infrared spectroscopy /
[ Broad,N.W.;Jee,R.D.;Moffat,A.C.;Eaves,M.J.;Mann,W.C.;Dziki,W. ] / Analyst   DOI   ScienceOn
10 The transfer between instruments of a reflectance near-infrared assay for paracetamol in intact tablets /
[ Smith,M.R.;Jee,R.D.;Moffat,A.C. ] / Analyst   DOI   ScienceOn
11 Optimisation of sample presentation for the near-infrared spectra of pharmaceutical excipients /
[ Yoon,W.L.;Jee,R.D.;Moffat,A.C. ] / Analyst   DOI   ScienceOn
12 Validation of a near-infrared transmission spectroscopic procedure, part A: validation protocols /
[ Mark,H.;Ritchie,G.E.;Roller,R.W.;Ciurczak,E.W.;Tso,C.;MacDonald,S.A. ] / J, Pharm. Biomed. Anal.   DOI   ScienceOn
13 Development and validation of a method for the analysis of a pharmaceutical preparation by near-infrared diffuse reflectance spectroscopy /
[ Blanco,M.;Coello,J.;Eustaquio,A.;Iturriaga,H.;Maspoch,S. ] / J. Pharm. Sci.   DOI   ScienceOn
14 Quantitative analysis of film coating in a fluidized bed process by in-line NIR spectrometry and multivariate batch calibration /
[ Andersson,M.;Folestad,S.;Gottfries,J.;Johansson,M.O.Josefson,M.;Wahlund,K.G. ] / Anal. Chem.   DOI   ScienceOn
15 Near Infrared Reflectance Spectroscopy (NIRS): Analysis of Forage Quality /
[ Marten,G.C.;Shenk,J.S.;Barton,F.E. ] / Agriculture Handbook
16 Near-infrared spectroscopy and imaging for the monitoring of powder blend homogeneity /
[ El-Hagrasy,A.S.;Morris,H.R.;D'Amico,F.;Lodder,R.A.;Drennen,J.K.3rd. ] / J. Pharm. Sci.   DOI   ScienceOn
17 Development and validation of methods for the determination of miokamycin in various pharmaceutical preparations by use of near infrared reflectance spectroscopy /
[ Blanco,M.;Coello,J.Eustaquio,A.Itturriaga,H.;Maspoch,S. ] / Analyst   DOI   ScienceOn
18 Validation of a near-infrared transmission spectroscopic procedure. Part B: Application to alternate content uniformity and release assay methods for pharmaceutical solid dosage forms /
[ Ritchie,G.E.;Roller,R.W.;Ciurczak,E.W.;Mark,H.;Tso,C.;MacDonal,S.A. ] / J. Pharm. Biomed. Anal.   DOI   ScienceOn
19 /
[ 대한보건공정서협회 ] / 대한약전 (제7개정)
20 One hundred percent caline identity check of pharmaceutical products by nearinfrared spectroscopy on the packaging line /
[ Perkert,T.;Prinz,H.;Kovar,K. ] / Eur. J. Pharm. Biopharm.   DOI   ScienceOn