• 제목/요약/키워드: Rotor Misalignment

검색결과 33건 처리시간 0.034초

경사 편심에 의한 유도전동기의 자기흡인력 평가 (Calculation of Unbalanced Magnetic Pull of Induction Motors due to Rotor Misalignment)

  • 김선화;양보석;김현철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1321-1327
    • /
    • 2006
  • This paper presents the calculation of unbalanced magnetic pull (UMP) that causes rotor misalignment in induction motor. The excessive noise and vibration will be occurred by means of rotor misalignment. Angular misalignment of rotor will produce air-gap permeance wave which is function of axial and circumferential coordinate. In this paper, the UMP is calculated using permeance and magneto motive force (MMF) in the case of static and dynamic misalignment. Based on the percentage of misalignment, the result shows that the UMP and magnetic pressure are increased according to the increasing of misalignment. The UMP is occurred not only in It frequency component but also the others.

  • PDF

BLDC 전동기의 동적 편심 및 전자기적 불평형력을 고려한 편심 회전자의 과도 동적 해석 (Transient Dynamic Analysis of a Dynamci Eccentric Rotor with Unbalanced Magnetic Forces in BLDC Motors)

  • 김태종;황상문;박노길
    • 소음진동
    • /
    • 제10권3호
    • /
    • pp.401-409
    • /
    • 2000
  • Vibration of a BLDC motor is a coupled phenomenon between mechanical characteristics and magnetic origins through the motor air-gap. When a relative misalignment of rotor in the air-gap center exists on the assemblage it is considered to influence the motor system characteristics, depending on the degree of misalignment. The rotor-motor system used in a washing machine is modeled using FE-TM and a magnetic force of BLDC motor with radial rotor eccentricity is analyzed. And the transient whirl responses of a rotor system with relative misalignment in the motor air-gap are investigated considering mechanical origins and magnetic effects. Results show that rotor misalignment in the air-gap affect the vibration of the rotor-motor system.

  • PDF

Effects of Rotor Misalignment in Airgap on Dynamic Response of an Eccentric Rotor in BLDC Motor

  • Kim, Tae-Jong;Kim, Kyung-Tae;Hwang, Sang-Moon;Park, No-Gill;Lee, Shi-Bok
    • Journal of Mechanical Science and Technology
    • /
    • 제16권12호
    • /
    • pp.1576-1582
    • /
    • 2002
  • Vibration of a BLDC motor is a coupled phenomenon between mechanical characteristics and magnetic origins which takes place through the motor airgap. When relative misalignment of a rotor in the airgap is introduced during assembly, the dynamic characteristics of the motor system are affected. The rotor-motor system used in a washing machine is modeled using FETM and magnetic forces in a BLDC motor with radial rotor eccentricity are determined analytically The transient whirl responses of a rotor system supported on two roller bearings with relative misalignment in the motor airgap are investigated by considering mechanical and magnetic coupling effects. Results show that rotor misalignment in the airgap considerably affects the vibration of the rotor-motor system.

정렬불량을 가진 기어 커플링의 동역학적 모델 개발에 관한 연구 (I) - 기어 커플링의 동적모델 구축을 중심으로- (A Study on Development the Dynamic Model to Misaligned Gear Coupling (I) - The Focus on Development of Dynamic Model to n Gear Coupling)

  • 김병옥;김용철
    • 대한기계학회논문집A
    • /
    • 제27권6호
    • /
    • pp.857-863
    • /
    • 2003
  • In rotating machinery, unbalance and misalignment are major concerns in vibration. Unbalance can be eliminated by balancing procedure to some degree. but little work has been done on the vibrations that occur in a misaligned rotor system. Currently, no generalized theoretical model based on a rotor system with flexible coupling is available to describe the vibrations caused by misalignment. As a part of systematic investigation on the misalignment, first of all, the study on flexible coupling with misalignment should be preceded. In this study, the geometry and reaction force and moment of a gear coupling with misalignment was investigated, also the theoretical model of a gear coupling with misalignment was presented by using the relationship between geometry and moment of gear coupling. It is expected that the proposed procedure can be applied to derive the theoretical model of other couplings.

홀센서를 이용한 모노레일 PMSM 견인전동기의 벡터제어 (Vector control of Monorail PMSM traction motor using the hall-effect sensor)

  • 손동혁;김명수;최다운;조윤현
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1366-1370
    • /
    • 2010
  • This paper supposes the vector control algorithm to estimate the rotor position of permanent magnet synchronous traction motor using the hall-effect sensor. The hall-effect provides 60 electrical degrees resolution in rotor position sensing and it is very low resolution. The algorithm makes resolution high as optical encoders or electromagnetic resolver. If necessary, the reference rotor position angle is controlled by adjusting the variable. When a rotor position sensor such as either a optical encoder or a electromagnetic resolver is misalignment, it is useful to align with those. The method on adjusting the reference rotor position angle can compensate for misalignment error degrees by 60 electrical degrees.

  • PDF

회전자 편심을 가지는 IPM, SPM 전동기 진동 특성 비교: (1) 영구 자석에 의한 전자기력 (Comparison of Vibration Characteristics in IPM and SPM BLDC Motors with Rotor Eccentricity : (1) Electro-magnetic Force Due to PM)

  • 황근배;김경태;황상문
    • 한국소음진동공학회논문집
    • /
    • 제11권9호
    • /
    • pp.454-461
    • /
    • 2001
  • Acoustic noise and vibration of a BLDC motor is a coupled phenomenon between mechanical characteristics and electromagnetic origins through the motor air-gap. When a relative misalignment of rotor in the air-gap center exists on the assemblage, it is considered to influence the motor system characteristics. In this paper, the back electro motive force(BEMF) is analyzed by Finite Element Method(FEM) and verified by experiments for the SPM and IPM type motors. For magnetic field analysis, a FEM is used to account for the magnetic saturation. Using these results, the FEM is made to determine the appropriate electromagnetic field analysis in BLDC motors with rotor eccentricity ratio. A radial magnetic imbalance force of BLDC motor with rotor eccentricity is analyzed. Results demonstrate that the imbalance force is increased according to the degree of misalignment. An IPM motor, mostly chosen to realize high-speed operation, shows a worse effect on magnetic unbalanced forces and dynamic responses compared with SPM motor due to magnetic saturation when the rotor eccentricity exists.

  • PDF

축정렬 불량시 베어링 특성 변화에 따른 발전소 증기 터빈의 동특성 연구 (Study of Dynamic Characteristics of Angular Misalignment of High-pressure Turbine in 1000MW Nuclear Power Plant)

  • 손석만;이준신;유기완;이선기;김태룡
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.664-669
    • /
    • 2000
  • Angular misalignment is one of the important causes for shaft vibration of turbine-generator in 1000MW nuclear power plant. It may cause the plant unexpected shutdown and subsequent accident. The change of dynamic characteristics in journal bearing and rotor due to angular misalignment in high pressure turbine is analyzed. The stiffness/damping coefficients of journal bearing increase as angular misalignment. Subsequently the natural frequency of HP turbine is changed. It was found that the natural frequency may locate near 2 times operating frequency in case of severe misalignment.

  • PDF

Effects of Misalignment of High Speed Flexible Coupling on the Fighter Aircraft Transmission Characteristics

  • Samikkanu, Nagesh;Basha, Abu Muhammed Junaid
    • International Journal of Fluid Machinery and Systems
    • /
    • 제5권2호
    • /
    • pp.91-99
    • /
    • 2012
  • The Fighter aircraft transmission system consists of a light weight, High Speed Flexible Coupling (HSFC) known as Power Take-Off shaft (PTO) for connecting Engine gearbox (EGB) with Accessory Gear Box (AGB). The HSFC transmits the power through series of specially contoured metallic annular thin flexible plates whose planes are normal to the torque axis. The HSFC operates at high speed ranging from 10,000 to 18,000 rpm. The HSFC is also catered for accommodating larger lateral and axial misalignment resulting from differential thermal expansion of the aircraft engine and mounting arrangement. The contoured titanium alloy flexible plates are designed with a thin cross sectional profile to accommodate axial and parallel misalignment by the elastic material flexure. This paper investigates the effect of misalignment on the transmission characteristics of the HSFC couplings. A mathematical model for the HSFC coupling with misalignment has been developed for analyzing the torque transmission and force interaction characteristics. An extensive testing has been conducted for validating characteristics of the designed coupling under various misalignment conditions. With this the suitability of the model adapted for the design iteration of HSFC development is validated. This method will reduce the design iteration cycles of HSFC and can be extended for the similar development of flexible couplings.

기계평면시일의 기하학적 형태가 압력분포에 미치는 영향에 관한 연구 (Geometric Effects on Pressure Distribution in Mechanical Face Seals)

  • 김청균;이일권
    • Tribology and Lubricants
    • /
    • 제5권2호
    • /
    • pp.48-54
    • /
    • 1989
  • The effects of angular misalignment, coning and the temperature difference between the primary seal ring and the seal seat on the pressure distribution in mechanical face seals are analyzed. The modified Reynolds equation for the temperature dependent viscosity was solved by a finite difference approximation and Gauss-Seidel method. It is shown that the amplitude of pressure is significantly affected by the misalignment of the seals and a large temperature difference between the rotor and the stator.

정렬불량 진단을 위한 유전알고리듬 기반 특징분석 (Feature Analysis based on Genetic Algorithm for Diagnosis of Misalignment)

  • 하정민;안병현;유현탁;최병근
    • 한국소음진동공학회논문집
    • /
    • 제27권2호
    • /
    • pp.189-194
    • /
    • 2017
  • An compressor that is combined with the rotor and pneumatic technology has been researching for the performance of pressure. However, the control of operations, an accurate diagnosis and the maintenance of compressor system are limited though the simple structure of compressor and compression are advantaged to reduce the energy. In this paper, the characteristic of the compressor operating under the normal or abnormal condition is realized. and the efficient diagnosis method is proposed through feature based analysis. Also, by using the GA (genetic algorithm) and SVM (support vector machine) of machine learning, the performance of feature analysis is conducted. Different misalignment mode of learning data for compressor is evaluated using the fault simulator. Therefore, feature based analysis is conducted considering misalignment mode of the compressor and the possibility of a diagnosis of misalignment is evaluated.