• 제목/요약/키워드: Rotatory

검색결과 204건 처리시간 0.032초

비장애 아동과 전반적 발달장애 아동에서 회전 후 안구진탕 기간의 비교 (The Difference of Duration of Post-rotatory Nystagmus Test Between Normal Children and Children With Pervasive Developmental Disorder)

  • 김진미;송지원;홍은경;김성희;김경미
    • 대한감각통합치료학회지
    • /
    • 제3권1호
    • /
    • pp.1-11
    • /
    • 2005
  • Objective : The purpose of this study was to get the mean of duration of post-rotatory nystagmus test in normal children and to differentiate the duration of post-rotatory nystagmus test between normal children and children with pervasive developmental disorder. Method : 84 subjects were between 3 and 5 years of age and consisted of 64 normal children and 20 children with the pervasive developmental disorder. Analysis of the data was done by using t-test and ANOVA. Results : The results were as follows: 1. Range of duration of post-rotatory nyatagmus test in normal children was $5{\sim}22$second on left and $7{\sim}21$ second on right and the mean was 12.63 second on left and 12.59 second on right. 2. Range of duration of post-rotatory nystagmus test in children with the pervasive developmental disorder was $3{\sim}11$ second on both and the mean was 5.65 second on left and 5.60 second on right. 3. There was no significant difference between males and females with normal children in duration of post-rotatory nystagmus test. However, there was a significant difference of the mean duration between 3 and 5 years old normal group. 4. Children with pervasive developmental disorder significantly have relatively lower duration than the duration of post-rotatory nystagmus test of normal children. Conclusions : The results of the study showed significant difference between normal children and children with pervasive developmental disorder in duration of post-rotatory nystagmus test and suggest that they could be applied to the baseline of clinical therapy.

  • PDF

회전형 이상 횡자속형 전동기에서 발생하는 자기력 및 토크 해석 (Analysis of the Magnetic Force and Torque of a Rotatory Two-Phase Transverse Flux Machine)

  • 박남기;장정환;장건희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.829-835
    • /
    • 2006
  • Rotatory two-phase transverse flux machine(TFM) is a relatively new type of motor with high power density, high torque, and low speed in comparison to conventional electrical motors. However, it has some shortcomings,.i.e. complex construction and high possibility of the magnetically induced vibration due to its inherent structure. This paper investigates the characteristics of the magnetic force and the torque in the rotatory two-phase TFM by using the 3-D finite element method and the spectral analysis. This research shows that the average torque decreases and that the torque ripple increases as the phase delay increases. It also shows that the unbalanced magnetic force is one of the dominant excitation forces in this machine. And it proposes a new topology of rotatory two-phase TFM to eliminate the unbalanced magnetic force.

  • PDF

Fuzzy Rule Base에 의한 Sinusoidal Rotatory Chair System의 구현 (Implementation of Sinusoidal Rotatory Chair System with Fuzzy Rule Base)

  • 차인수;박해암;백형래
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.582-584
    • /
    • 1994
  • A sinusoidal rotatory chair system using a self-tuning and following control by a fuzzy was designed to evaluate the vestibular function and to apply to a robot driving power system. The experimental results by the sinusoidal rotatory chair system were pretty good and whitch had smaller then ${\pm}210$ pulse error on the ${\pm}810^{\circ}$ sinusoidal rotation at 0.12 Hz by using a 850W DC servo motor. As a results, the sinusoidal rotatory chair system may be useful to evaluate the vestibular function in the field of medicine, and it can be used to robotics or a numerical control system (NC) on the industry if the the obtained control method and the system are adapted for a channel.

  • PDF

Atlantoaxial Rotatory Fixation - 3 례 보 고 - (Atlantoaxial Rotatory Fixation - Report of 3 Cases -)

  • 손문준;임승철;노성우;박형천
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권4호
    • /
    • pp.580-585
    • /
    • 2000
  • The atlantoaxial rotatory fixation is a uncommon disease of deformity, occuring much more frequently in children than in adults. Despite of its benign clinical course, delayed recognition or improper management may cause persistent deformity or recurrence. We report three cases of typical atlantoaxial rotatory fixation. Successful reduction was achieved with posterior atlantoaxial fusion in one case and nonoperative treatment in others. We emphasize that it is necessary to perform dynamic CT scan to obtain correct diagnosis and to plan proper treatment for this disease entity.

  • PDF

PNF 패턴에서 회전요소에 관한 고찰 (A Study of Rotatory Factor in PNF Pattern)

  • 최재원;김미현;정현애
    • PNF and Movement
    • /
    • 제1권1호
    • /
    • pp.1-9
    • /
    • 2003
  • Objectives: The main purpose of this study is to analyze the importance of the rotatory factor in PNF pattern. In this article has to analyze and clarify the importance of the rotatory factor in PNF pattern by comparing the general concepts, facilitation technics, and neuroscience of muscle spindle, etc. Methods: This is a literature study with books. Results : There is close relationships between the pattern in PNF and rotatory factor. PNF pattern is priorily made up the diagonal and spiral pattern. the rotatory factor influences and guides from the start to end in the pattern. Conclusions : Rotation component is most important of the three component that one flexion or extension, abduction or adduction and rotation. It is that provide longer muscle length and stimulate the muscle spindles.

  • PDF

전정기능 평가 및 질병 진단을 위한 정현파 회전자극기 개발 (Functional Assessment of Vestibular System and Dizziness Diagnosis)

  • 정호춘;임승관;김규겸;진달복
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.1027-1030
    • /
    • 1996
  • The purpose of this study was to develop systematic diagnostic system testing easily, rapidly vestibular function of patients suffered from vestibular syndrome such as nausea vomiting, dizzness, ataxia. Diagnostic system composed of rotatory chair system which rotated sinusoidally patients against their vertical axis for purpose of invoking eye movement by vestibulo-ocular reflex and the softwares which storaged eye movement into computer and analyzed eye movement. Rotatory chair system consisted of comfortable chair and DC servomotor with reducer(1:80) by controlled servo in field of nonlinear motor control, double feedback loops system containing velocity feedback loop and position feedback loop was applied to this sever controlled rotatory chair system. Maximum rotatory velocity of rotatory chair was upto 60 degree per second and frequency range was 0.01 to 0.64 Hz. These above results suggest that clinical rotatory chair system may test easily, rapidly vestibular function and diagnose etiology of dizziness, thus giving effective assistance on the treatment of dizziness patients.

  • PDF

회전형 이상 횡자속형 전동기에서 발생하는 자기력 및 토크 해석 (Analysis of the Magnetic Force and Torque of a Rotatory Two-phase Transverse Flux Machine)

  • 박남기;장정환;장건희
    • 한국소음진동공학회논문집
    • /
    • 제17권1호
    • /
    • pp.33-40
    • /
    • 2007
  • Rotatory two-phase transverse flux machine(TFM) is a relatively new type of motor with high power density, high torque, and low speed in comparison to conventional electrical motors. However, it has some shortcomings,.i.e. complex construction and high possibility of the magnetically induced nitration due to its inherent structure. This Paper investigates the characteristics of the magnetic force and the torque in the rotatory two-phase TFM by using the 3-D finite element method and the spectral analysis. This research shows that the average torque decreases and that the torque ripple increases as the phase delay increases. It also shows that the unbalanced magnetic force is one of the dominant excitation forces in this machine. And it proposes a new topology of rotatory two-phase TFM to eliminate the unbalanced magnetic force.

회전관성 및 전단변형을 고려한 띠기초의 자유진동 (Free Vibrations of Strip Foundations with Rotatory Inertia and Shear Deformation)

  • 이준규
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.675-680
    • /
    • 2006
  • This paper deals with the flexural free vibrations of strip foundations. Based on dynamic equilibrium equations of a beam element resting on Winkler foundation, differential equations governing free vibration of strip foundation are derived, in which effects of rotatory inertia and shear deformation are included. For obtaining the natural frequencies, differential equations are solved by numerical methods. As the numerical results, relationships between natural frequencies and various strip parameters are obtained and presented in Tables and Figures.

  • PDF

주관절의 외측방 회전 불안정성에 대한 외측 척측부인대 재건술-1례보고- (Lateral Ulnar Collateral Ligament Reconstruction for Posterolateral Rotatory Instability of the Elbow Joint - A Case Report -)

  • 문은선;이승기;박철홍
    • Clinics in Shoulder and Elbow
    • /
    • 제1권2호
    • /
    • pp.236-241
    • /
    • 1998
  • 본 교실에서는 주관절에 발생한 후외측방 회전 불안정성에 의한 재발성 탈구 환자에 대해 Nestor 술식을 이용한 외측 척측부인대 재건을 1례 치 험하였다. 주관절의 재발성 탈구의 치료에 있어서는 병인중 가장 많은 후외측방 회전 불안정성에 대한 이해가 필요하며 그에 따른 외측 척측부인대 재건등의 수술적 수기와 술후 적절한 재활 치료가 치료결과에 큰 영향을 미치게 된다.

  • PDF

회전관성과 전단변형을 고려한 수평 곡선보의 자유진동 (Free Vibrations of Horizontally Curved Beams with Rotatory Inertia and Shear Deformation)

  • 이병구;모정만;이태은;안대순
    • 한국소음진동공학회논문집
    • /
    • 제13권1호
    • /
    • pp.63-69
    • /
    • 2003
  • The ordinary differential equations governing free vibrations of elastic horizontally curved beams are derived, in which the effects of rotatory inertia and shear deformation as well as the effects of both vertical and torsional inertias are included. Frequencies and mode shapes are computed numerically for parabolic curved beams with the hinged-hinged, hinged-clamped and clamped-clamped ends. Comparisons of natural frequencies between this study and ADINA are made to validate the theories and numerical methods developed herein. The lowest three natural frequency parameters are reported. with and without the effects of rotatory inertia and shear deformation. as functions of the three non-dimensional system parameters: the horizontal rise to span length ratio. the slenderness ratio and the stiffness parameter.