• Title/Summary/Keyword: Rotational-off system

Search Result 34, Processing Time 0.024 seconds

Screw machining system by use of rotational tool with Y axis off-set on a CNC turning center (Y축이 Off-Set된 회전공구를 사용한 스크류 가공시스템)

  • Choi, N.H.;Lee, W.K.;Ahn, J.H.
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.809-813
    • /
    • 2000
  • In this study, screw machining system by use of a rotational tool such as an end-mill or a face cutter with Y axis off-set on a CNC turing center was developed for quick machining. In this system, It was possible to use different tools for different processes, and by off-setting the tool in Y direction by calculated amount it was possible to avoid tool interference problem which could occur within the central area at the end of a tool. In addition, machining a screw with a helix of up to 3 different leads combined and with tapered minor diameter was possible.

  • PDF

Site Evaluation and Application of the On-line and Off-line Test for the 13[kV] Class Hydropower Generator Stator Windings (13[kV]급 수력발전기 고정자 권선의 운전 및 정지 중 진단시험 현장적용 평가 및 분석)

  • Chang, Jeong-Ho;Lee, Dong-Keun;Lee, Heung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.11
    • /
    • pp.73-82
    • /
    • 2011
  • The solid insulation system of stator windings in high voltage rotational machines is usually aging in accordance with long time operation. The partial discharge test have been known to check whether insulation deterioration exist or not, and the PD test can effectively diagnose a solid insulation condition regardless of during operation(on-line) or not(off-line). The on-line PD measurement have proven to be a successful technique in monitoring stator insulation condition nowadays. This paper describes the characteristics of comparing the on-line PD measurement data using PDMS-HG(Partial Discharge Monitoring System for Hydro-electric Generator) installed in field with the off-line diagnosis measurement data(insulation resistance, winding resistance, PI, ${\Delta}tan{\delta}$ and PD) on hydro generator(13[kV]) stator windings. These results make good use of managing rotational machines through evaluating the solid insulation condition of stator windings.

An Experimental Study on the Tappet Spin for a Direct Acting Valve Train System (직접 구동형 밸브 트레인 시스템의 태핏 회전에 관한 실험적 연구)

  • Cho, Myung-Rae;Kim, Hyung-Jun;Moon, Tae-Seon;Han, Dong-Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.7
    • /
    • pp.1179-1184
    • /
    • 2003
  • The technique for measuring the rotational speed of tappet in direct acting type valve train system has been developed. The optic signal monitoring system with laser and optic fiber was designed to follow the signal of tappet rotation. The system was based on ON/OFF signal generation from the additional encoder teeth under the tappet with optic fibers attached photo transistor. The data showed that tappet rotation was affected by offset, oil temperature and cam shaft operating speed. Also it was found that tappet rotation increases with oil temperature. Tappet spin was delayed 10∼s20$^{\circ}$ cam angle after valve opening. The instantaneous rotational speed of tappet was reciprocal to cam shaft speed and the tappet and the cam angle ratio was located in the range of 0.1∼0.3.

Study on performance prediction of centrifugal compressor with diffuser angle and rotational speed change (원심압축기의 디퓨져 각도조절과 회전수변경에 따른 성능예측에 관한 연구)

  • Park, Y.H.;Shim, Y.H.;Kim, C.S.;Cho, S.Y.
    • Journal of Power System Engineering
    • /
    • v.16 no.5
    • /
    • pp.55-62
    • /
    • 2012
  • Centrifugal compressors are widely used and each operating condition is different. However, it cannot be manufactured according to the every operating condition. In the this study, performance of compressor was evaluated with various rotational speeds of impeller and various stagger angles of diffuser in order to apply a typical model widely. A centrifugal compressor was designed and manufactured based on the design point. On this machines, an experiment was conducted and the performance was predicted at off-design point. The performance prediction was validated with the experimental result and the numerical result. Although the isentropic efficiency on the prediction was slightly lower than that on the experimental result due to the heat loss in the experiment, the pressure ratio was predicted well and also the predicted results were matched well with the numerical results. When the rotational speed of the impeller and the stagger angle of the diffuser were changed together, the compressor can be worked in the high efficiency region and avoided operating in the stall region.

The characteristics of capacity control using a variable speed compressor in an industrial cooler (산업용 냉각기의 압축기 회전수 변화에 따른 용량제어 특성)

  • Baek, S.M.;Moon, C.G.;Yoon, J.I.;Jeong, S.K.;Kim, E.
    • Journal of Power System Engineering
    • /
    • v.15 no.2
    • /
    • pp.37-41
    • /
    • 2011
  • This paper presents the capacity-control characteristics in an industrial cooler with a variable speed compressor. The inverter-type compressor is controlled by the rotational speed of the operational frequency. This type of the compressor performs the wide range of load compared to the on-off type. When the load of the system reduces, the rotational speed will be reduced. Thus, the system leads to the less power consumption and extends the longer durability of the compressor. With the variable rotational speed of the compressor the cooling capacity of the cooler is about 1.6-3.6 kW and the capacity control is about 40-100%. The system showed the highest efficiency when the rotational speed is about 45-70 Hz. The results can be used as the basic design data to control an industrial cooler.

The Nocturnal Changes of Plasma Melatonin Concentrations in Night Shift Workers : Comparison of the Clockwise and Counterclockwise Rotational Shift. (야간 근무시의 혈장 멜라토닌의 농도 변화 : 시계 방향과 반시계 방향의 교대근무 비교)

  • Min, Soon;Kim, Mi-Seung;Im, Wook-Bin
    • Journal of Korean Biological Nursing Science
    • /
    • v.2 no.2
    • /
    • pp.81-89
    • /
    • 2000
  • To determine the optimal rotational shift system, the effect of the direction of the rotational work shifting on the nocturnal rhythm of plasma melatonin were investigated in nursing students. Two groups of nine volunteers participated as experimental subjects, and two nursing students participated as a control group. The directions of the rotational work shift were as follows: CW(clockwise)-shift were rotated in the direction of day shift(3 days), evening shift(3 days), off duty(1 day) and night shift(5 days), and CCW(conuterclockwise)-shift were done in the reverse direction. Plasma melatonin concentrations was measured by radioimmunoassay. The results were as follows : The plasma melatonin levels were kept low at night and in the following morning in the CW night shift workers, whereas the level started to increase at 05 : 00 hr in two workers of four CCW shift workers. These result suggests that the shift rotation in the CW direction is more acceptable in terms of the adaptation of hormonal rhythms. These results indicate that the CCW rotation of shift work is somewhat better than CCW rotation for the adaptation to shift work on hormonal aspects in nurses.

  • PDF

Consciousness of Fire Officers and Improving the Working Conditions (소방공무원 의식과 처우개선에 관한 연구)

  • Kim, Kook-Rae
    • Fire Science and Engineering
    • /
    • v.21 no.1 s.65
    • /
    • pp.7-18
    • /
    • 2007
  • This research intended to show a reasonable way to improve working conditions of fire officers in Korea. It shows that fire officers have dignity of their social roles even though they have the unfairness in a work time, rewards, promotions and opportunities of overseas training compared with those of other government officers. The unfairness needs to be solved. In addition, there are more demands in fire fighters, but part of a regional government system already composed of 64.06% of fire officers, which means, there are too many fire fighters in one regional government. Therefore, it is difficult to employ more fire fighters. This is one of barriers to prevent from improvement of the working conditions. To improve the working conditions and to overcome the barriers, there are important solutions to counter the problems. Those are application of alternative policies and systems. Compared with the employment system and workload of fire officers in USA, Japan and other advanced countries, it is necessary to introduce alternative policies which include operation of partial three-shift system, expansion of oversees training, expansion of rotational-off system and improvement of employees' welfare policies.

SCARA robot calibration on off-line programming (오프라인 프로그래밍에서 스카라 로봇의 보정)

  • Jung, Sung-Woo;Son, Kwon;Lee, Min-Chul;Choi, Jae-Won
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1832-1835
    • /
    • 1997
  • Off-line programming systems are widely spread in assembly lines of minute electronic products to huge offshore structures. Any OLP system has to be calibrated before the on-line robot tasks are performed because there are inherent differences between the CAD model on OLP and the real robot workspace. This paper uses simple geometric expressions to propose a calibration method applicable to an OLP for SCARA robots. A positioning task on the two-dimensional horizontal surface was used in the error analysis of a SCARA robot and the anaysis shows that the inaccuracy results from the two error sources non-zero offset angles of two rotational joints at the zero return and differences in link lengths. Pen marks on a sheet of plotting paper are used to determine the accurate data on the joint centers and link dimensions. The calculated offset angles and link lengths are fed back to the OLP for the calibration of the CAD model of the robot and task environments.

  • PDF

An Optimal Approach to Rotational Vibration Suppression using Disturbance Observer in Disk Drive Systems

  • Park, Sung-Won;Kim, Nam-Guk;Chu, Sang-Hoon;Kang, Chang-Ik;Lee, Ho-Seong
    • Transactions of the Society of Information Storage Systems
    • /
    • v.3 no.1
    • /
    • pp.5-12
    • /
    • 2007
  • This paper investigates the design of disturbance observer for rotational vibration suppression in disk drive systems. The design aims to provide an optimal controller which satisfies both vibration performance and robust stability. It consists of an inversion method, a special filter, and optimization scheme. Firstly a new inversion method is introduced, which provides more accurate inversion compared to conventional zero phase error method. The inversion is to deal with unstable zeros in the plant model. Secondly a special filter for disturbance selection is given, which features adjustable gain and band pass characteristics so that it enables flexible shaping of the loop considering the trade-off between performance and stability margins. And finally the parameters of disturbance observer are optimized in conjunction with external disturbance model. Simulation and experiment on commercial hard disk drives confirm that the design is very effective to such disturbance which is hard to be handled by conventional approach.

  • PDF

An Experimental Study on Performance and Flow Characteristics of Automotive Sirocco Fan (자동차용 시로코팬의 성능 및 유동특성에 관한 실험적 연구)

  • 유성연;이대웅
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.11
    • /
    • pp.954-963
    • /
    • 2002
  • For the optimal design of an automotive blower system, effects of the scroll cut-off starting angle, the clearance between blade tip and bellmouth, and the scroll expansion angle on the performance of sirocco fan are investigated experimentally. Best performance is achieved at fan exposure ratio $\Deltae/r_c$,/TEX> =1.0, and clearance ratio $\DeltaeC/C=0.62. Flow characteristics inside sirocco fan are also studied by using LDV. Flow patterns in the inside of fan can be classified into three regions. Velocity vector has the same direction as rotational direction of fan at 0~$120^{\circ}$, toward the fan blades at 150~$180^{\circ}$, and opposite direction at 210~$330^{\circ}$. Turbulent intensity is relatively high near the cut-off edge in the scroll housing.